Kenmore 796.7927#, 796.6927# manual KEY Parts and Components

Page 7

KEY PARTS AND COMPONENTS

There are several important components that are referenced in this manual.

O EASY-TO-USE CONTROL PANEL

Rotate the Cycle Selector Knob to select the desired dry cycle. Add cycle options or adjust settings with the touch of a button.

OTIME AND STATUS DISPLAY

The easy-to-read LED display shows cycle status and estimated time remaining.

CYCLE MODIFIERS

Adjust the cycle defaults such as temperature and dry level with the touch of a button.

NOTE: Not all settings are available for all cycles. See page 24.

STEAM FEEDER

This lid provides access to the reservoir for the water used by the dryer to create steam for the STEAM REFRESH cycle and other steam features.

CHECK VENT

(Duct Blockage Sensing System)

The Check Vent (Duct blockage sensing system) detects and alerts you to blockages in the exhaust system that reduce airflow from the dryer. Maintaining clean exhaust system ducts improves operating efficiency and helps minimize service calls, saving you money.

U LTRA-CAPACITY STAI N LESS STEEL DRUM WITH DRUM LIGHT

The ultra-large stainless steel drum offers superior durability. The drum is equipped with a light that illuminates when the dryer door is open and turns off when the door is closed.

O EASY-ACCESS REVERSIBLE DOOR

Wide-opening, see-through glass door provides easy access for loading and unloading. Door swing can be reversed to adjust for installation location.

FRONT-MOUNT LINT FILTER

Front-mount lint filter allows for easy access and cleaning between loads.

Terminal Block Power Cord

Access Panel Location

(Electric Models) (Gas Models)

LEVELING FEET

Gas Connection

Exhaust Duct

Four leveling feet (two in front, and two in back) adjust to improve dryer stability on uneven floors.

Location

Outlet

(Gas Models)

Rear of Dryer

Image 7
Contents Protocol P154 Kenmore EliteMaster Protection Agreements Sears installationRi=AD ALL iNSTRUCTiONS Bsfors USE Follow basic precautions, including the following Basic Safety PrecautionsExhaust/Ducting Safety Instructions for Steam Functions KEY Parts and Components Choose the Proper Location KEY Dimensions SpecificationsAdditional Instructions for closet installations Location RequirementsOptional Accessories Electrical Requirements for Gas Models Only GAS Requirements GAS Models onlyFollowing Electric shock, or injury to persons when usingThis appliance, follow basic precautions, including WA RN I N k. To reduce the risk of fireWarn ING Toreducetheriskoffire Electrical Requirements Connecting Electric DryersWire connection is not permitted on Connecting Electric DryersFour-Wire Power Cord Three-Wire Power CordVenting the Dryer Check Your Exhaust System for Problems Selecting and Verifying Duct Length ChartUsing the Duct Requirements Chart below Connecting the Dryer Vent Routing and Connecting DuctworkVenting the Dryer Leveling the Dryer Reversingthe Door Checking Levelness Final Installation CheckTesting Dryer Heating Checking VentingControl Panel Features Select Cycle Options Operating the DryerSelect a Cycle Select Cycle ModifiersTimed Dry Cycles Cycle GuideDuty CasualGrouping Similar Items Sorting LoadsLoading the Dryer Check the Lint Filter Before Every LoadControl Lock Indicator Lint Filter IndicatorCycle Status Indicator Check Vent IndicatorTemp Cycle Modifier ButtonsTo Add Cycle Options to a Cycle Cycle Options and Special FeaturesUsing the Static Shield Option Using the Steam Refresh cycleSteam Functions Important Notes about Steam Cycles To Fill the Steam FeederCleaning the Lint Filter Cleaning the ExteriorCleaning the Interior Cleaning Around and Under the DryerDryer will not turn on Before Calling for Service Check Vent Indicator is BlinkingGreasy or dirty spots on clothes Excess static in clothes after dryingCheck Then Before Calling for SERVICEcontDrying time is not consistent Clothes take too long to dryClothes are shrinking Clothes are wrinkledSteam Features Not Working Optional Accessories Option 1 side venting Gasdryerscanonlybeventedtotheleftside Side Venting KIT InstallationList of Parts Tools NeededDisclaimer of implied warranties limitation of remedies One-Year Limited WarrantyPage Page Instrucciones Importantes Servicio de instalaci6n SearsGuarde estas instrucciones Daos a la propiedad, lesiones personales o muerteMuerte Precauciones basicas de seguridadConducto de escape/Tuberia Guarde Estas Instrucciones Piezas Y Componentes Significativos Espacios Libres Dimensiones Especificaciones SignificativasRequisitos DE Ubicacion Escoger LA Ubicacion CorrectaAccesorios Opcionales Requerimientos DE GAS Solo Modelos DE GAS Requerimientos electricos solo para modelos de gasConexion DE LAS Secadoras DE GAS De servicios Conexion DE LAS Secadoras DE GASLa instalacion Mantenimiento Deben Instalador CualificadoConexion DE LAS Secadoras DE Elictricas Requerimientos DE ELI!CTRICOSCion a partir del 1 de enero de Cable De alimentacion TetrafilarCable de alimentacion trifilar Prefabricadas,asi como toda nueva construcVentilacion DE LA Secadora Trayectoria y conexion de los conductos Ventilacion DE LA SecadoraConexion del conductode venti/acionde/a secadora Nivelacion DE LA Secadora AdvertenciaDE LA Puerta InversionTornillo de Comprobacion de la nivelacion Comprobacion Final DE LA InstalacionPrueba de calentamiento de la secadora Comprobacion de la ventilacionFunciones DEL Panel DE Control Iniciar EL ClCLO Funcionamiento DE LA SecadoraCargar LA Secadora Encender LA Secadora= opci6n disponible Guja DE CiclosAgrupacion de prendas similares Clasificacion DE CargasCarga DE LA Secadora Comprobar EL Filtro DE Pelusas Antes DE Cada CargaIndicador DE Estado DEL Ciclo Pantalla DE Tiempo Y EstadoTiempo Restante Estimado Indicador DEL Filtro DE PelusasTimed DRY tiempo de secado Botones Modificadores DE CicloDRY Level nivel de secado Secado ManualEncienda La secadora Opciones DEL ClCLO Y Funciones EspecialesAjusta en Alta y el nivel de humedad en MUY SECO. Estos Ajustes predeterminados no pueden cambiarseUtilizacion del cicIo Steam Refresh refresco por vapor Funciones DE VaporUtilizacion de la opcion Static Shield anti-estatica Notas Importantes Acerca DE LOS Ciclos DE Vapor Para rellenar el alimentador de vaporLimpieza alrededor y bajo la secadora Limpieza RegularLimpieza del exterior Limpieza del interiorCompruebe SI EL Indicador DE Ventilacion EST.& Parpadeando La secadora no se enciendeLa secadora no calienta Manchas de grasa o suciedad en las prendasLas prendas tardan mucho en secarse El tiempo de secado no es consistenteAntes DE Solicitar Asistencia Ticnica Pelusa sobre las prendas La pantalla muestra el codigo de error tElLas prendas estan arrugadas Las prendas han encogidoAntes DE Solicitar Asistencia Las funciones de vapor no estan operativasTicnica Accesorios Opcionales Opcion 2 ventilacion per la base Herramientas necesariasInstalacion DEL KIT DE Ventilacion Lateral Listado de piezasGarantia limitada de un ao Managemylife