ADC WDA-540, AD-295, AD-26, AD-540 user manual Operating Instructions, Timed Mode

Page 12

SECTION III

OPERATING INSTRUCTIONS

NOTE: Unless otherwise specified at the time of ordering, the Phase 5 coin microprocessor controller (computer) has been preprogrammed by the factory with the parameters shown on page 52 and page 53 (for ALL dryer models except AD-26/AD-295and AD-540/WDA-540) and page 54 and page 55 (for dryer models AD-26/AD-295and AD-540/WDA-540only). Should program changes be found necessary, please read this Phase 5 Coin User’s Manual carefully to thoroughly familiarize yourself with the Phase 5 coin microprocessor controller (computer) programming characteristics.

A. TIMED MODE

1.When turning on power or when no cycle is in progress, the light emitting diode (L.E.D.) display will read “FILL” and/or “Amount To Start” (“AtSt”).

2.Insert coin(s). Once the correct “Amount To Start” has been inserted, the L.E.D. display will read “PUSH.”

3.Select temperature by pushing “HI TEMP,” “LO TEMP,” or “PERM PRESS.” The dryer will start and the L.E.D. display will read the temperature cycle selected and the drying time.

4.The dryer will continue through the drying and cooling cycles, showing time counting downward.

NOTE: If the door is opened during a cycle, both the heat and motor will stop. However, the Phase 5

coin microprocessor controller (computer) will continue to count downwards in time. Continuation of the cycle will resume only after the door has been closed and any one (1) of the three (3) temperature selection buttons is again depressed.

5.Upon completion of the drying and cooling cycles, the buzzer (tone) will sound, and the L.E.D. display will read “donE” for 5-seconds, at which time the dryer will shut off.

NOTE: If theAnti-Wrinkle Program is active (“Grd”), the L.E.D. display will remain reading “donE,” and the Phase 5 coin microprocessor (computer) will proceed through theAnti-Wrinkle Program until the maximum “Guard On Time” has expired or until the door is opened, whichever comes first. The L.E.D. display will read “FILL” and/or “Amount To Start” (“AtSt”).

NOTE: If theAnti-Wrinkle Program is not active (“nGrd”) the L.E.D. display will read “donE” until the main door is opened, at which time the L.E.D. display will read “FILL” and/or “Amount To Start.”

10

Image 12
Contents Phase Coin USER’S Manual Retain This Manual In a Safe Place For Future Reference Important Note to PurchaserTable Of Contents Programming Instructions Motor Circuit Indicator For all dryer models except AD-26/AD-295 and AD-540/WDA-540For dryer models AD-26/AD-295 Only Introduction Time for Amount to Start Cool Down Temperatures Free DRY ModeCool Down Time ANTI-WRINKLETemperature Display DiagnosticsBatterybackup Optional Automatic DrytimeD. Displayand Codes ClccFill FLSLCC PlocPPF PushTimed Mode Operating InstructionsAutomatic Mode Patent no ,827,627 Free DRY Mode Temperature Display Mode Program SelectionRight Coin Count rCC/LEFT Coin Count LCC Automatic Review of Program Location PL01 Temperature Conversion Status Automatic Mode AUtO Patent No ,827,627Timed Mode tInE Free DRY Mode FrEE ANTI-WRINKLE Program GrdBUZZ/TONE bUZ Coin Mode Coin BAD Coin Reset bCrSFlash Display Status FLS BAD Coin Lockout Status bCLOAccumulative Time AtIn Single CoinDual Coin PL10 rCdE PL11 tFAS PL12 AtSt Accumulative Coin ACOn Single Coin AcceptorDual Coinacceptor PL03 High Temperature HIF Rotational Safe Guard OPTIONALnSEnPL02 Percent DRY PdrY PL05 LOW Temperature LOF PL07 Permanent Press PPFPL10 Right Coin Slot Denomination rCdE PL11 Time for Amount to Start tFASPL12 Amount to Start AtSt PL13 Minimum Amount for Additional Time AFAtPL15 ANTI-WRINKLE Timing PL16 Active Guard Time AGtPL17 a and b Factors Programming Instructions Introduction to ProgrammingProgramming Flowcharts Dryer Off Power On Display Reads No cycle in progress ButtonExample And/orTemperature Display Mode ProgrammingCycle In Progress Left Coin Count Right Coin Count Program Location 01 PL01 Display will read anti-wrinkle Guard program status. If no changePress Perm Press key, otherwise Press HI or LO keys and thenFLS AtIn LO Temp Continue HI Temp Program Location 02 PL02 PL02 Perm Press PdryPerm Press PL03 Program Location 03 PL03 HIFHI Temp cool down temperature/time Program Location 04 PL04Time Decrease Time Increase Program Location 05 PL05 LO Temp cool down temperature/time Program Location 06 PL06Time Decrease Program Location 07 PL07 PPFPerm Press Cool Down Temperature/Time Program Location 08 PL08Program Location 09 PL09 PL09 Perm Press LCdEProgram Location 10 PL10 Right Coin DenominationProgram Location 11 PL11 Program Location 12 PL12 Proceed to next location To be changed PL12 Perm Press AtStProgram Location 13 PL13 Proceed to next location To be changed PL13 Perm Press AFAtProgram Location 14 PL14 Maximum Time for Auto DryProgram Location 15 PL15 Anti-Wrinkle TimingProgram Location 16 PL16 and Program Location 17 PL17 Maximum Active Anti-Wrinkle TimeProgrammable 1 to Factor Decrease Factor IncreaseFactory Preset PROGRAMS/PARAMETERS Single Coin only Dual Coin only LCdE Left coin denomination 10¢TFAS Time for amount to start 10 minutes AFAt Amount for additional time 10¢HICd Temperature 80, Time 2 minutes LOCd Temperature 80, Time 2 minutesPPCd Temperature 80, Time 3 minutes NSEn Rotational sensor not selected PdrY Percent Dry 98%PL06 LOCd Temperature 80, Time 2 minutes PL08 PPCd Temperature 80, Time 3 minutesRCdE Right coin denomination 10¢ Phase 5 Coin System Diagnostics Diagnostic L.E.D. Failure CodesE.D. Display INDICATORS/DOTS Page Page Phase 5 Auto Cycle Patent no ,827,627 For 60 Hz models only For 50 Hz models only Optional 9 Volt Battery Backup Page ADC Part No 56 10/28/08