ADC AD-295, WDA-540 PL01 Temperature Conversion Status, Automatic Mode AUtO Patent No ,827,627

Page 17

PL01 - TEMPERATURE CONVERSION STATUS

This program controls whether the temperature related programs will be operated in Fahrenheit (°F) or Celsius (°C). The programs affected are:

1.Temperature Display Mode

2.Selection Cycling Temperatures

3.Cool Down Temperatures

AUTOMATIC MODE (AUtO) Patent No. 4,827,627

When this parameter (“AUtO”) is selected, the dryer will run for a preset level of dryness (PL02) or until the programmed automatic maximum time (PL14) has expired.

At the end of the drying cycle, the dryer will go into the cool down cycle for the time period programmed (PL04, PL06, or PL08) or until the temperature has dropped to the programmed cool down temperature (PL04, PL06, or PL08).

NOTE: Due to humidity, atmospheric pressure, percentage of extraction, etc., the desired dryness level may vary. It is suggested that the owner determine which level of dryness (90% to 100%) is best suited for his/her application by experimenting with a few test loads.

NOTE: When programming, to use the Automatic Mode (“AUtO”) (Patent No. 4,827,627), the

following parameter/programs need to be checked and/or changed accordingly:

PL01

“AUtO”

PL02

“FrEE” or “Coin” (coins required to start)

“PdrY” (percent dry from 90% to 100%)

PL14

“Adrt” (maximum auto dry time)

PL17

“A” and “b” Factors

TIMED MODE (tInE)

When this parameter is selected (‘tInE”) and the Phase 5 coin microprocessor controller (computer) has been activated, the dryer will continue to run until the preset time, including the cool down period (PL04, PL06, or PL08), has elapsed, at which time the dryer will continue to run until the preset time, including the cool down period (PL04, PL06, or PL08), has elapsed, at which time the dryer will cycle off or go into the optional Anti-Wrinkle Program.

15

Image 17
Contents Phase Coin USER’S Manual Important Note to Purchaser Retain This Manual In a Safe Place For Future ReferenceTable Of Contents Programming Instructions For dryer models AD-26/AD-295 Only Motor Circuit IndicatorFor all dryer models except AD-26/AD-295 and AD-540/WDA-540 Introduction Time for Amount to Start Free DRY Mode Cool Down TemperaturesCool Down Time ANTI-WRINKLEDiagnostics Temperature DisplayBatterybackup Optional Automatic DrytimeClcc D. Displayand CodesFill FLSPloc LCCPPF PushOperating Instructions Timed ModeAutomatic Mode Patent no ,827,627 Free DRY Mode Right Coin Count rCC/LEFT Coin Count LCC Temperature Display ModeProgram Selection Automatic Review of Program Location Timed Mode tInE PL01 Temperature Conversion StatusAutomatic Mode AUtO Patent No ,827,627 BUZZ/TONE bUZ Free DRY Mode FrEEANTI-WRINKLE Program Grd BAD Coin Reset bCrS Coin Mode CoinFlash Display Status FLS BAD Coin Lockout Status bCLODual Coin Accumulative Time AtInSingle Coin PL10 rCdE PL11 tFAS PL12 AtSt Dual Coinacceptor Accumulative Coin ACOnSingle Coin Acceptor PL02 Percent DRY PdrY PL03 High Temperature HIFRotational Safe Guard OPTIONALnSEn PL07 Permanent Press PPF PL05 LOW Temperature LOFPL11 Time for Amount to Start tFAS PL10 Right Coin Slot Denomination rCdEPL12 Amount to Start AtSt PL13 Minimum Amount for Additional Time AFAtPL17 a and b Factors PL15 ANTI-WRINKLE TimingPL16 Active Guard Time AGt Introduction to Programming Programming InstructionsProgramming Flowcharts Button Dryer Off Power On Display Reads No cycle in progressAnd/or ExampleCycle In Progress Temperature Display ModeProgramming Left Coin Count Right Coin Count Program Location 01 PL01 Guard program status. If no change Display will read anti-wrinklePress Perm Press key, otherwise Press HI or LO keys and thenFLS AtIn LO Temp Continue HI Temp Perm Press PL03 Program Location 02 PL02PL02 Perm Press Pdry HIF Program Location 03 PL03Time Decrease Time Increase HI Temp cool down temperature/timeProgram Location 04 PL04 Program Location 05 PL05 Time Decrease LO Temp cool down temperature/timeProgram Location 06 PL06 PPF Program Location 07 PL07Program Location 08 PL08 Perm Press Cool Down Temperature/TimePL09 Perm Press LCdE Program Location 09 PL09Right Coin Denomination Program Location 10 PL10Program Location 11 PL11 Proceed to next location To be changed PL12 Perm Press AtSt Program Location 12 PL12Proceed to next location To be changed PL13 Perm Press AFAt Program Location 13 PL13Maximum Time for Auto Dry Program Location 14 PL14Anti-Wrinkle Timing Program Location 15 PL15Maximum Active Anti-Wrinkle Time Program Location 16 PL16 and Program Location 17 PL17Programmable 1 to Factor Decrease Factor IncreaseFactory Preset PROGRAMS/PARAMETERS Single Coin only LCdE Left coin denomination 10¢ Dual Coin onlyTFAS Time for amount to start 10 minutes AFAt Amount for additional time 10¢LOCd Temperature 80, Time 2 minutes HICd Temperature 80, Time 2 minutesPPCd Temperature 80, Time 3 minutes NSEn Rotational sensor not selected PdrY Percent Dry 98%RCdE Right coin denomination 10¢ PL06 LOCd Temperature 80, Time 2 minutesPL08 PPCd Temperature 80, Time 3 minutes Diagnostic L.E.D. Failure Codes Phase 5 Coin System DiagnosticsE.D. Display INDICATORS/DOTS Page Page Phase 5 Auto Cycle Patent no ,827,627 For 60 Hz models only For 50 Hz models only Optional 9 Volt Battery Backup Page ADC Part No 56 10/28/08