B.AUTOMATIC MODE (PATENT NO. 4,827,627)

1.When turning on power or when no cycle is in progress, the light emitting diode (L.E.D.) display will read “FILL” and/or “Amount To Start” (“AtSt”).

2.Insert coin(s). Once correct “Amount To Start” has been inserted, the L.E.D. display will read “PUSH.”

3.Select temperature by pushing “HI TEMP,” “LO TEMP,” or “PERM PRESS.” The dryer will start, the L.E.D. display will read the temperature cycle selected, and the drying time portion of the L.E.D. display will read “00” and count upward as time elapses.

NOTE: If the door is opened during a cycle, both the heat and motor will stop. However, the Phase 5 coin microprocessor controller (computer) will continue to count upwards in time. Continuation of the cycle will resume only after the door has been closed and any one (1) of the three (3) temperature selection buttons is again depressed.

4.Once the preprogrammed dryness level and cool down period have been reached or maximum automatic time has expired, whichever comes first, the buzzer (tone) will sound, and the L.E.D. display will read “donE” for 5-seconds, at which time the dryer will shut off.

NOTE: If theAnti-Wrinkle Program is active (“Grd”), the L.E.D. display will remain reading “donE,” and the Phase 5 coin microprocessor controller (computer) will proceed through the Anti-Wrinkle Program until the maximum “Guard On Time” has expired or door is opened, whichever comes first. The L.E.D. will read “FILL” and/or “Amount To Start” (“AtSt”).

NOTE: If theAnti-Wrinkle Program is not active (“nGrd”), the L.E.D. display will read “donE” until the main door is opened, at which time the L.E.D. display will read “FILL” and/or “Amount To Start.”

11

Image 13
Contents Phase Coin USER’S Manual Important Note to Purchaser Retain This Manual In a Safe Place For Future ReferenceTable Of Contents Programming Instructions For all dryer models except AD-26/AD-295 and AD-540/WDA-540 Motor Circuit IndicatorFor dryer models AD-26/AD-295 Only Introduction Time for Amount to Start Free DRY Mode Cool Down TemperaturesCool Down Time ANTI-WRINKLEDiagnostics Temperature DisplayBatterybackup Optional Automatic DrytimeClcc D. Displayand CodesFill FLSPloc LCCPPF PushOperating Instructions Timed ModeAutomatic Mode Patent no ,827,627 Free DRY Mode Program Selection Temperature Display ModeRight Coin Count rCC/LEFT Coin Count LCC Automatic Review of Program Location Automatic Mode AUtO Patent No ,827,627 PL01 Temperature Conversion StatusTimed Mode tInE ANTI-WRINKLE Program Grd Free DRY Mode FrEEBUZZ/TONE bUZ BAD Coin Reset bCrS Coin Mode CoinFlash Display Status FLS BAD Coin Lockout Status bCLOSingle Coin Accumulative Time AtInDual Coin PL10 rCdE PL11 tFAS PL12 AtSt Single Coin Acceptor Accumulative Coin ACOnDual Coinacceptor Rotational Safe Guard OPTIONALnSEn PL03 High Temperature HIFPL02 Percent DRY PdrY PL07 Permanent Press PPF PL05 LOW Temperature LOFPL11 Time for Amount to Start tFAS PL10 Right Coin Slot Denomination rCdEPL12 Amount to Start AtSt PL13 Minimum Amount for Additional Time AFAtPL16 Active Guard Time AGt PL15 ANTI-WRINKLE TimingPL17 a and b Factors Introduction to Programming Programming InstructionsProgramming Flowcharts Button Dryer Off Power On Display Reads No cycle in progressAnd/or ExampleProgramming Temperature Display ModeCycle In Progress Left Coin Count Right Coin Count Program Location 01 PL01 Guard program status. If no change Display will read anti-wrinklePress Perm Press key, otherwise Press HI or LO keys and thenFLS AtIn LO Temp Continue HI Temp PL02 Perm Press Pdry Program Location 02 PL02Perm Press PL03 HIF Program Location 03 PL03Program Location 04 PL04 HI Temp cool down temperature/timeTime Decrease Time Increase Program Location 05 PL05 Program Location 06 PL06 LO Temp cool down temperature/timeTime Decrease PPF Program Location 07 PL07Program Location 08 PL08 Perm Press Cool Down Temperature/TimePL09 Perm Press LCdE Program Location 09 PL09Right Coin Denomination Program Location 10 PL10Program Location 11 PL11 Proceed to next location To be changed PL12 Perm Press AtSt Program Location 12 PL12Proceed to next location To be changed PL13 Perm Press AFAt Program Location 13 PL13Maximum Time for Auto Dry Program Location 14 PL14Anti-Wrinkle Timing Program Location 15 PL15Maximum Active Anti-Wrinkle Time Program Location 16 PL16 and Program Location 17 PL17Programmable 1 to Factor Decrease Factor IncreaseFactory Preset PROGRAMS/PARAMETERS Single Coin only LCdE Left coin denomination 10¢ Dual Coin onlyTFAS Time for amount to start 10 minutes AFAt Amount for additional time 10¢LOCd Temperature 80, Time 2 minutes HICd Temperature 80, Time 2 minutesPPCd Temperature 80, Time 3 minutes NSEn Rotational sensor not selected PdrY Percent Dry 98%PL08 PPCd Temperature 80, Time 3 minutes PL06 LOCd Temperature 80, Time 2 minutesRCdE Right coin denomination 10¢ Diagnostic L.E.D. Failure Codes Phase 5 Coin System DiagnosticsE.D. Display INDICATORS/DOTS Page Page Phase 5 Auto Cycle Patent no ,827,627 For 60 Hz models only For 50 Hz models only Optional 9 Volt Battery Backup Page ADC Part No 56 10/28/08