ADC AD-26, WDA-540, AD-295, AD-540 Phase 5 Coin System Diagnostics, Diagnostic L.E.D. Failure Codes

Page 58

SECTIONVIII

PHASE 5 COIN SYSTEM DIAGNOSTICS

ALL major circuits, including door, microprocessor temperature sensor, heat and motor circuits are monitored. The Phase 5 coin microprocessor controller (computer) will inform the user via the light emitting diode (L.E.D.) display of certain failure codes along with indicators both in the L.E.D. display and at the outputs of each relay (and door switch circuit) to easily identify failures.

A. DIAGNOSTIC (L.E.D.) FAILURE CODES

1.“door” - Indicates door switch circuit is open.

a.Keyboard (touch pad) entry was made while main door is open or

b.there is a fault in the door switch circuit (external of the microprocessor controller [computer]).

2.“dSFL” - Indicates a fault in the microprocessor temperature sensor circuit. If a fault is detected in the microprocessor heat sensor circuit, the L.E.D. display will read “dSFL” and the buzzer (tone) will sound for approximately 5-seconds every 30-seconds.

a.the problem is corrected

or

b. power to dryer is discontinued...and the problem is then corrected.

IMPORTANT: The Phase 5 coin microprocessor controller (computer) has its own internal heat sensing circuit fuse protection located on the back side of the (computer). If a “dSFL” condition occurs, check to see if this fuse has blown. If it has, DO NOT replace the entire microprocessor controller (computer); replace only the fuse and do so only with a 1/8-Amp (Slo-Blo) type fuse.

NOTE: Once the Phase 5 coin microprocessor controller (computer) detects a problem in the heat circuit, it updates every 30-seconds so if a problem was a loose connection in this circuit, which corrected itself, the “dSFL” condition would automatically be cancelled.

56

Image 58
Contents Phase Coin USER’S Manual Retain This Manual In a Safe Place For Future Reference Important Note to PurchaserTable Of Contents Programming Instructions For all dryer models except AD-26/AD-295 and AD-540/WDA-540 Motor Circuit IndicatorFor dryer models AD-26/AD-295 Only Introduction Time for Amount to Start Cool Down Time Cool Down TemperaturesFree DRY Mode ANTI-WRINKLEBatterybackup Optional Temperature DisplayDiagnostics Automatic DrytimeFill D. Displayand CodesClcc FLSPPF LCCPloc PushTimed Mode Operating InstructionsAutomatic Mode Patent no ,827,627 Free DRY Mode Program Selection Temperature Display ModeRight Coin Count rCC/LEFT Coin Count LCC Automatic Review of Program Location Automatic Mode AUtO Patent No ,827,627 PL01 Temperature Conversion StatusTimed Mode tInE ANTI-WRINKLE Program Grd Free DRY Mode FrEEBUZZ/TONE bUZ Flash Display Status FLS Coin Mode CoinBAD Coin Reset bCrS BAD Coin Lockout Status bCLOSingle Coin Accumulative Time AtInDual Coin PL10 rCdE PL11 tFAS PL12 AtSt Single Coin Acceptor Accumulative Coin ACOnDual Coinacceptor Rotational Safe Guard OPTIONALnSEn PL03 High Temperature HIFPL02 Percent DRY PdrY PL05 LOW Temperature LOF PL07 Permanent Press PPFPL12 Amount to Start AtSt PL10 Right Coin Slot Denomination rCdEPL11 Time for Amount to Start tFAS PL13 Minimum Amount for Additional Time AFAtPL16 Active Guard Time AGt PL15 ANTI-WRINKLE TimingPL17 a and b Factors Programming Instructions Introduction to ProgrammingProgramming Flowcharts Dryer Off Power On Display Reads No cycle in progress ButtonExample And/orProgramming Temperature Display ModeCycle In Progress Left Coin Count Right Coin Count Program Location 01 PL01 Press Perm Press key, otherwise Display will read anti-wrinkleGuard program status. If no change Press HI or LO keys and thenFLS AtIn LO Temp Continue HI Temp PL02 Perm Press Pdry Program Location 02 PL02Perm Press PL03 Program Location 03 PL03 HIFProgram Location 04 PL04 HI Temp cool down temperature/timeTime Decrease Time Increase Program Location 05 PL05 Program Location 06 PL06 LO Temp cool down temperature/timeTime Decrease Program Location 07 PL07 PPFPerm Press Cool Down Temperature/Time Program Location 08 PL08Program Location 09 PL09 PL09 Perm Press LCdEProgram Location 10 PL10 Right Coin DenominationProgram Location 11 PL11 Program Location 12 PL12 Proceed to next location To be changed PL12 Perm Press AtStProgram Location 13 PL13 Proceed to next location To be changed PL13 Perm Press AFAtProgram Location 14 PL14 Maximum Time for Auto DryProgram Location 15 PL15 Anti-Wrinkle TimingProgrammable 1 to Factor Decrease Program Location 16 PL16 and Program Location 17 PL17Maximum Active Anti-Wrinkle Time Factor IncreaseFactory Preset PROGRAMS/PARAMETERS Single Coin only TFAS Time for amount to start 10 minutes Dual Coin onlyLCdE Left coin denomination 10¢ AFAt Amount for additional time 10¢PPCd Temperature 80, Time 3 minutes HICd Temperature 80, Time 2 minutesLOCd Temperature 80, Time 2 minutes NSEn Rotational sensor not selected PdrY Percent Dry 98%PL08 PPCd Temperature 80, Time 3 minutes PL06 LOCd Temperature 80, Time 2 minutesRCdE Right coin denomination 10¢ Phase 5 Coin System Diagnostics Diagnostic L.E.D. Failure CodesE.D. Display INDICATORS/DOTS Page Page Phase 5 Auto Cycle Patent no ,827,627 For 60 Hz models only For 50 Hz models only Optional 9 Volt Battery Backup Page ADC Part No 56 10/28/08