ADC WDA-540, AD-295, AD-26, AD-540 user manual Accumulative Time AtIn, Single Coin, Dual Coin

Page 20

ACCUMULATIVE TIME (AtIn)

(SINGLE COIN)

In this program mode (“AtIn”), each coin inserted has a specific value in time which is determined by the “Time For Amount To Start” (“tFAS”) program (PL11).

Example No. 1: If the dryer is equipped with a 25¢ coin acceptor and the desired time is 30 minutes, each additional coin inserted would yield 30 minutes.

Settings: PL09 (LCdE)

25

PL11 (tFAS)

30

PL12 (AtSt)

25

Example No. 2: If the dryer is equipped with a 25¢ coin acceptor and the “Amount To Start” (“AtSt”) is 50¢ for 30 minutes, the insertion of each additional coin would yield 15 minutes. In this application the “Time For Amount To Start” (“tFAS”) is determined by a Phase 5 coin microprocessor controller (computer) calculation. There is no calculation required by the owner.

Formula: (LCdE/AtSt) (tFAS) = Vended Time for “ LCdE” (25¢/50¢) (30) = 15 minutes

Settings: PL09 (LCdE)

25

PL11 (tFAS)

30

PL12 (AtSt)

50

(DUAL COIN)

In the accumulative time (AtIn) mode, when using a dual coin acceptor, once the “Amount To Start” (“AtSt”) has been inserted, the addition of a coin(s) yields more time. The amount time accumulated for each additional coin inserted is determined by the “Time For Amount To Start” (“tFAS”) program (PL11).

The “Time For Amount To Start” (“tFAS”) is determined by a Phase 5 coin microprocessor controller (computer) calculation of additional amounts installed.

Formula: (LCdE/AtSt) (tFAS) = Vended Time

Example No. 1: Using a 10¢/25¢ dual coin acceptor with the desired “Amount To Start” (“AtSt”) being 25¢ for 15 minutes, each additional 10¢ would yield the following:

Formula: (LCdE/AtSt) (tFAS) = Vended Time for “LCdE” (10¢/25¢) (15 minutes) 6 minutes

Settings: PL09 (LCdE)

10

PL10 (rCdE)

25

PL11 (tFAS)

15

PL12 (AtSt)

25

18

Image 20
Contents Phase Coin USER’S Manual Retain This Manual In a Safe Place For Future Reference Important Note to PurchaserTable Of Contents Programming Instructions For dryer models AD-26/AD-295 Only Motor Circuit IndicatorFor all dryer models except AD-26/AD-295 and AD-540/WDA-540 Introduction Time for Amount to Start Cool Down Temperatures Free DRY ModeCool Down Time ANTI-WRINKLETemperature Display DiagnosticsBatterybackup Optional Automatic DrytimeD. Displayand Codes ClccFill FLSLCC PlocPPF PushTimed Mode Operating InstructionsAutomatic Mode Patent no ,827,627 Free DRY Mode Right Coin Count rCC/LEFT Coin Count LCC Temperature Display ModeProgram Selection Automatic Review of Program Location Timed Mode tInE PL01 Temperature Conversion StatusAutomatic Mode AUtO Patent No ,827,627 BUZZ/TONE bUZ Free DRY Mode FrEEANTI-WRINKLE Program Grd Coin Mode Coin BAD Coin Reset bCrSFlash Display Status FLS BAD Coin Lockout Status bCLODual Coin Accumulative Time AtInSingle Coin PL10 rCdE PL11 tFAS PL12 AtSt Dual Coinacceptor Accumulative Coin ACOnSingle Coin Acceptor PL02 Percent DRY PdrY PL03 High Temperature HIFRotational Safe Guard OPTIONALnSEn PL05 LOW Temperature LOF PL07 Permanent Press PPFPL10 Right Coin Slot Denomination rCdE PL11 Time for Amount to Start tFASPL12 Amount to Start AtSt PL13 Minimum Amount for Additional Time AFAtPL17 a and b Factors PL15 ANTI-WRINKLE TimingPL16 Active Guard Time AGt Programming Instructions Introduction to ProgrammingProgramming Flowcharts Dryer Off Power On Display Reads No cycle in progress ButtonExample And/orCycle In Progress Temperature Display ModeProgramming Left Coin Count Right Coin Count Program Location 01 PL01 Display will read anti-wrinkle Guard program status. If no changePress Perm Press key, otherwise Press HI or LO keys and thenFLS AtIn LO Temp Continue HI Temp Perm Press PL03 Program Location 02 PL02PL02 Perm Press Pdry Program Location 03 PL03 HIFTime Decrease Time Increase HI Temp cool down temperature/timeProgram Location 04 PL04 Program Location 05 PL05 Time Decrease LO Temp cool down temperature/timeProgram Location 06 PL06 Program Location 07 PL07 PPFPerm Press Cool Down Temperature/Time Program Location 08 PL08Program Location 09 PL09 PL09 Perm Press LCdEProgram Location 10 PL10 Right Coin DenominationProgram Location 11 PL11 Program Location 12 PL12 Proceed to next location To be changed PL12 Perm Press AtStProgram Location 13 PL13 Proceed to next location To be changed PL13 Perm Press AFAtProgram Location 14 PL14 Maximum Time for Auto DryProgram Location 15 PL15 Anti-Wrinkle TimingProgram Location 16 PL16 and Program Location 17 PL17 Maximum Active Anti-Wrinkle TimeProgrammable 1 to Factor Decrease Factor IncreaseFactory Preset PROGRAMS/PARAMETERS Single Coin only Dual Coin only LCdE Left coin denomination 10¢TFAS Time for amount to start 10 minutes AFAt Amount for additional time 10¢HICd Temperature 80, Time 2 minutes LOCd Temperature 80, Time 2 minutesPPCd Temperature 80, Time 3 minutes NSEn Rotational sensor not selected PdrY Percent Dry 98%RCdE Right coin denomination 10¢ PL06 LOCd Temperature 80, Time 2 minutesPL08 PPCd Temperature 80, Time 3 minutes Phase 5 Coin System Diagnostics Diagnostic L.E.D. Failure CodesE.D. Display INDICATORS/DOTS Page Page Phase 5 Auto Cycle Patent no ,827,627 For 60 Hz models only For 50 Hz models only Optional 9 Volt Battery Backup Page ADC Part No 56 10/28/08