ADC AD-26, WDA-540, AD-295, AD-540 ANTI-WRINKLE Program Grd, BUZZ/TONE bUZ, Free DRY Mode FrEE

Page 18

ANTI-WRINKLE PROGRAM (Grd)

This feature can be used in conjunction with any of the three (3) operating modes (Coin Mode, Auto Mode, or the Free Dry Mode). In this program (“Grd”), when the drying and cooling cycles are completed, the dryer will shut off, the buzzer (tone) will sound, and the light emitting diode (L.E.D.) display will read “donE.” If the door is not opened, the Phase 5 coin microprocessor controller (computer) will wait until the “Guard Delay Time” (PL15) has expired, at which time the clothes will be tumbled (without heat) for the programmed ”Guard On Time” (PL15). The Phase 5 coin microprocessor controller (computer) will repeat this process until the programmed “Active Guard Time” (PL16) has expired or until the dryer door is opened, at which time the L.E.D. display will read “FILL” and/or “Amount To Start” (“AtSt”) or “FILL” and/or “FrEE.”

NOTE: When programming the use of theAnti-Wrinkle Program (“Grd”), the following parameter/ programs need to be checked and/or changed accordingly:

PL01

“Grd” (Anti-Wrinkle Program active)

PL15

“bUZ” or “nbUZ” (buzzer [tone] active/not active)

“GdLY” (guard delay time)

PL16

“Gont” (guard on time)

“AGt” (active guard time)

BUZZ/TONE (bUZ)

With the Anti-Wrinkle Program active, the option is available to have the buzzer/tone (“bUZ”) sound for a period of 5-seconds at the end of each “Guard On Time” cycle, or, no buzzer (“nbUZ”) sound.

FREE DRY MODE (FrEE)

The Phase 5 coin microprocessor controller (computer) can be programmed to run without the insertion of coins. When the Phase 5 coin microprocessor controller (computer) is in the “FrEE” dry mode, it may be programmed to run in the “AUtO” (Automatic) Mode or the “tInE” (Timed) Mode.

NOTE: When programming the use of the Free Dry Mode (“FrEE”), the following parameters/ programs need to be checked and/or changed accordingly;

PL01

“AUtO” (automatic drying cycle) or

PL02*

“tInE” (timed drying cycle) “FrEE”

“PdrY” (percent dry)

PL14*

“Adrt” (maximum auto dry time)

PL17*

“A” and “b” factors

* Needs to be programmed only if PL01 “AUtO” Cycle is chosen.

16

Image 18
Contents Phase Coin USER’S Manual Retain This Manual In a Safe Place For Future Reference Important Note to PurchaserTable Of Contents Programming Instructions Motor Circuit Indicator For all dryer models except AD-26/AD-295 and AD-540/WDA-540For dryer models AD-26/AD-295 Only Introduction Time for Amount to Start Cool Down Time Cool Down TemperaturesFree DRY Mode ANTI-WRINKLEBatterybackup Optional Temperature DisplayDiagnostics Automatic DrytimeFill D. Displayand CodesClcc FLSPPF LCCPloc PushTimed Mode Operating InstructionsAutomatic Mode Patent no ,827,627 Free DRY Mode Temperature Display Mode Program SelectionRight Coin Count rCC/LEFT Coin Count LCC Automatic Review of Program Location PL01 Temperature Conversion Status Automatic Mode AUtO Patent No ,827,627Timed Mode tInE Free DRY Mode FrEE ANTI-WRINKLE Program GrdBUZZ/TONE bUZ Flash Display Status FLS Coin Mode CoinBAD Coin Reset bCrS BAD Coin Lockout Status bCLOAccumulative Time AtIn Single CoinDual Coin PL10 rCdE PL11 tFAS PL12 AtSt Accumulative Coin ACOn Single Coin AcceptorDual Coinacceptor PL03 High Temperature HIF Rotational Safe Guard OPTIONALnSEnPL02 Percent DRY PdrY PL05 LOW Temperature LOF PL07 Permanent Press PPFPL12 Amount to Start AtSt PL10 Right Coin Slot Denomination rCdEPL11 Time for Amount to Start tFAS PL13 Minimum Amount for Additional Time AFAtPL15 ANTI-WRINKLE Timing PL16 Active Guard Time AGtPL17 a and b Factors Programming Instructions Introduction to ProgrammingProgramming Flowcharts Dryer Off Power On Display Reads No cycle in progress ButtonExample And/orTemperature Display Mode ProgrammingCycle In Progress Left Coin Count Right Coin Count Program Location 01 PL01 Press Perm Press key, otherwise Display will read anti-wrinkleGuard program status. If no change Press HI or LO keys and thenFLS AtIn LO Temp Continue HI Temp Program Location 02 PL02 PL02 Perm Press PdryPerm Press PL03 Program Location 03 PL03 HIFHI Temp cool down temperature/time Program Location 04 PL04Time Decrease Time Increase Program Location 05 PL05 LO Temp cool down temperature/time Program Location 06 PL06Time Decrease Program Location 07 PL07 PPFPerm Press Cool Down Temperature/Time Program Location 08 PL08Program Location 09 PL09 PL09 Perm Press LCdEProgram Location 10 PL10 Right Coin DenominationProgram Location 11 PL11 Program Location 12 PL12 Proceed to next location To be changed PL12 Perm Press AtStProgram Location 13 PL13 Proceed to next location To be changed PL13 Perm Press AFAtProgram Location 14 PL14 Maximum Time for Auto DryProgram Location 15 PL15 Anti-Wrinkle TimingProgrammable 1 to Factor Decrease Program Location 16 PL16 and Program Location 17 PL17Maximum Active Anti-Wrinkle Time Factor IncreaseFactory Preset PROGRAMS/PARAMETERS Single Coin only TFAS Time for amount to start 10 minutes Dual Coin onlyLCdE Left coin denomination 10¢ AFAt Amount for additional time 10¢PPCd Temperature 80, Time 3 minutes HICd Temperature 80, Time 2 minutesLOCd Temperature 80, Time 2 minutes NSEn Rotational sensor not selected PdrY Percent Dry 98%PL06 LOCd Temperature 80, Time 2 minutes PL08 PPCd Temperature 80, Time 3 minutesRCdE Right coin denomination 10¢ Phase 5 Coin System Diagnostics Diagnostic L.E.D. Failure CodesE.D. Display INDICATORS/DOTS Page Page Phase 5 Auto Cycle Patent no ,827,627 For 60 Hz models only For 50 Hz models only Optional 9 Volt Battery Backup Page ADC Part No 56 10/28/08