COOL DOWN TIME

ALL three (3) temperature selections are programmable from a minimum of 0 minutes to a maximum of 9 minutes in 1 minute increments.

COOL DOWN TEMPERATURES

In the automatic or free dry modes, the cool down cycle termination is programmable from a minimum of 70° F to a maximum of 190° F in ten-degree increments or from a minimum of 21° C to a maximum of 88° C in five-degree increments.

AUTOMATIC MODE (Patent No. 4,827,627)

This program selection uses ADC’s patented Auto-Dry cycle. The microprocessor controller (computer) will calculate the percent of the dryness and read “donE” when complete. The Phase 5 coin microprocessor controller (computer) can be programmed to have a maximum time for the “Auto Mode.” The Automatic Cycle (mode) can be used in either the “Free Dry” Mode or the “Coin” Mode.

ANTI-WRINKLE

This program selection helps keep permanent press items wrinkle free when they are not removed from the dryer promptly at the end of the drying and cooling cycles. The Anti-Wrinkle program settings are:

1.Guard Delay Time ...................... 1 to 9 minutes

2.Guard On Time ........................... 1 to 99-seconds

3.Active Guard Time ..................... 1 to 99 minutes

FREE DRY MODE

In this program selection, the dryer can be started without the insertion of coins by simply pressing any one of the three (3) temperature selections. When set in the “Free Dry” Mode, the Phase 5 coin microprocessor controller (computer) can also be programmed to run with an Automatic Cycle (percent of dryness) or with a Timed Cycle. If the “Free Dry” program is utilized, the computer’s light emitting diode (L.E.D.) display will cycle back and forth between “FILL” to “FrEE,” unless otherwise programmed.

L.E.D. FLASH DISPLAY

Programmable to allow the L.E.D. readout to display a choice of “FILL” (no cycle in progress), “Amount To Start” (i.e., 25¢), or, in the case of free dry, “FrEE.” This program selection also allows the L.E.D. display to flash back and forth every 2-seconds from “FILL” to “Amount To Start” or, in the case of free dry, from “FILL” to “FrEE.”

AUDIBLE TONE

In this program selection, a tone (buzzer) will sound for each coin inserted, program entry, or at the drying and cooling cycles for a period of 5-seconds to indicate that the cycle is complete. Additionally, when in the Anti-Wrinkle program, the tone (buzzer) will sound for 5-seconds at the end of the “Guard On Time.”

6

Image 8
Contents Phase Coin USER’S Manual Retain This Manual In a Safe Place For Future Reference Important Note to PurchaserTable Of Contents Programming Instructions For dryer models AD-26/AD-295 Only Motor Circuit IndicatorFor all dryer models except AD-26/AD-295 and AD-540/WDA-540 Introduction Time for Amount to Start Cool Down Temperatures Free DRY ModeCool Down Time ANTI-WRINKLETemperature Display DiagnosticsBatterybackup Optional Automatic DrytimeD. Displayand Codes ClccFill FLSLCC PlocPPF PushTimed Mode Operating InstructionsAutomatic Mode Patent no ,827,627 Free DRY Mode Right Coin Count rCC/LEFT Coin Count LCC Temperature Display ModeProgram Selection Automatic Review of Program Location Timed Mode tInE PL01 Temperature Conversion StatusAutomatic Mode AUtO Patent No ,827,627 BUZZ/TONE bUZ Free DRY Mode FrEEANTI-WRINKLE Program Grd Coin Mode Coin BAD Coin Reset bCrSFlash Display Status FLS BAD Coin Lockout Status bCLODual Coin Accumulative Time AtInSingle Coin PL10 rCdE PL11 tFAS PL12 AtSt Dual Coinacceptor Accumulative Coin ACOnSingle Coin Acceptor PL02 Percent DRY PdrY PL03 High Temperature HIFRotational Safe Guard OPTIONALnSEn PL05 LOW Temperature LOF PL07 Permanent Press PPFPL10 Right Coin Slot Denomination rCdE PL11 Time for Amount to Start tFASPL12 Amount to Start AtSt PL13 Minimum Amount for Additional Time AFAtPL17 a and b Factors PL15 ANTI-WRINKLE TimingPL16 Active Guard Time AGt Programming Instructions Introduction to ProgrammingProgramming Flowcharts Dryer Off Power On Display Reads No cycle in progress ButtonExample And/orCycle In Progress Temperature Display ModeProgramming Left Coin Count Right Coin Count Program Location 01 PL01 Display will read anti-wrinkle Guard program status. If no changePress Perm Press key, otherwise Press HI or LO keys and thenFLS AtIn LO Temp Continue HI Temp Perm Press PL03 Program Location 02 PL02PL02 Perm Press Pdry Program Location 03 PL03 HIFTime Decrease Time Increase HI Temp cool down temperature/timeProgram Location 04 PL04 Program Location 05 PL05 Time Decrease LO Temp cool down temperature/timeProgram Location 06 PL06 Program Location 07 PL07 PPFPerm Press Cool Down Temperature/Time Program Location 08 PL08Program Location 09 PL09 PL09 Perm Press LCdEProgram Location 10 PL10 Right Coin DenominationProgram Location 11 PL11 Program Location 12 PL12 Proceed to next location To be changed PL12 Perm Press AtStProgram Location 13 PL13 Proceed to next location To be changed PL13 Perm Press AFAtProgram Location 14 PL14 Maximum Time for Auto DryProgram Location 15 PL15 Anti-Wrinkle TimingProgram Location 16 PL16 and Program Location 17 PL17 Maximum Active Anti-Wrinkle TimeProgrammable 1 to Factor Decrease Factor IncreaseFactory Preset PROGRAMS/PARAMETERS Single Coin only Dual Coin only LCdE Left coin denomination 10¢TFAS Time for amount to start 10 minutes AFAt Amount for additional time 10¢HICd Temperature 80, Time 2 minutes LOCd Temperature 80, Time 2 minutesPPCd Temperature 80, Time 3 minutes NSEn Rotational sensor not selected PdrY Percent Dry 98%RCdE Right coin denomination 10¢ PL06 LOCd Temperature 80, Time 2 minutesPL08 PPCd Temperature 80, Time 3 minutes Phase 5 Coin System Diagnostics Diagnostic L.E.D. Failure CodesE.D. Display INDICATORS/DOTS Page Page Phase 5 Auto Cycle Patent no ,827,627 For 60 Hz models only For 50 Hz models only Optional 9 Volt Battery Backup Page ADC Part No 56 10/28/08