Maytag MGDB850WL, W10261614A Install Leveling Legs, Connect Inlet Hose Steam Models, Connect Vent

Page 11

Install Vent System

1.Install exhaust hood. Use caulking compound to seal exterior wall opening around exhaust hood.

2.Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust hood with 4" (102 mm) clamp.

3.Run vent to dryer location. Use the straightest path possible. See “Determine vent path” in “Plan Vent System.” Avoid 90º turns. Use clamps to seal all joints. Do not use duct tape, screws,

or other fastening devices that extend into the interior of the vent to secure vent, which can catch lint.

INSTALL LEVELING LEGS

WARNING

Excessive Weight Hazard

Use two or more people to move and install dryer. Failure to do so can result in back or other injury.

1.To avoid damaging the floor, use a large flat piece of cardboard from the dryer carton. Place cardboard under the entire back edge of the dryer.

2.Firmly grasp the body of the dryer (not the console panel). Gently lay the dryer on the cardboard. See illustration.

3.Examine the leveling legs. Find the diamond marking.

CONNECT INLET HOSE

(STEAM MODELS)

The dryer must be connected to the cold water faucet using the new inlet hoses. Do not use old hoses.

1.Turn cold water faucet off and remove washer inlet hose.

2.Remove old rubber washer from inlet hose and replace with new rubber washer provided. If space permits, attach the brass female end of the “Y” connector to the cold water faucet.

NOTE: If “Y” connector can be attached directly to cold water faucet, go to Step 6. If “Y” connector cannot be attached directly to the cold water faucet, the short hose must be used. Continue with Step 3.

3.Attach short hose to cold water faucet. Screw on coupling by hand until it is seated on faucet.

4.Using pliers, tighten the couplings with an additional two-thirds turn.

NOTE: Do not overtighten. Damage to the coupling can result.

5.Attach “Y” connector to brass male end of small hose. Screw on coupling by hand until it is seated on connector.

6.One end of the long hose has a wire mesh strainer inside the coupling. Attach this end to the “Y” connector.

7.Attach washer cold inlet hose to other end of “Y” connector. Screw on coupling by hand until it is seated on connector.

A

4.Screw the legs into the leg holes by hand. Use a wrench to finish turning the legs until the diamond marking is no longer visible.

5.Place a carton corner post from dryer packaging under each of the 2 dryer back corners. Stand the dryer up. Slide the dryer on the corner posts until it is close to its final location. Leave enough room to connect the exhaust vent.

CONNECT VENT

1.Using a 4" (102 mm) clamp, connect vent to exhaust outlet

in dryer. If connecting to existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood. Check that the vent is secured to exhaust hood with a 4" (102 mm) clamp.

2.Move dryer into its final location. Do not crush or kink vent.

3.(On gas models) Check that there are no kinks in the flexible gas line.

4.Once the exhaust vent connection is made, remove the corner posts and cardboard.

A. Inlet to cold water

8.Using pliers, tighten the couplings an additional two-thirds turn. NOTE: Do not overtighten. Damage to the coupling can result.

11

Image 11
Contents Table DES Matières Instructions D’INSTALLATION DE LA SécheuseYour safety and the safety of others are very important Dryer SafetyWhat to do if YOU Smell GAS Location Requirements Installation RequirementsTools and Parts Optional EquipmentMobile home installations require Installation clearancesDryer Dimensions It is your responsibility Electric Dryer Power Hookup Canada onlyElectrical Requirements Gas Supply Requirements GAS Dryer Power HookupVenting Requirements If using an existing vent systemVenting Make Gas ConnectionIf this is a new vent system Vent material Plan Vent SystemDetermine vent path Optional exhaust installationsAlternate installations for close clearances Vent system chartConnect Vent Install Leveling LegsInstall Vent System Connect Inlet Hose Steam ModelsReverse Door Swing Complete InstallationLevel Dryer Dryer door opening Reinstall the doorReverse the strike Loosen the top screw from each of the 2 hinges in StepNo heat TroubleshootingDryer Operation Dryer will not runIs the exhaust vent the correct length? Dryer ResultsIs the lint screen clogged with lint? Are fabric softener sheets blocking the grille?Votre sécurité et celle des autres est très importante Sécurité DE LA SécheusePage Équipement facultatif Exigences D’INSTALLATIONExigences demplacement Outillage et piècesDe décharge de la sécheuse Dimensions de la sécheuse’installation dans une maison mobile exige Dégagements de séparation à respecter’est à l’utilisateur qu’incombe la responsabilité de Raccordement DE L’ALIMENTATION LA Sécheuse ÉlectriqueSpécifications électriques Canalisation d’arrivée de gaz Raccordement DE L’ALIMENTATION LA Sécheuse À GAZAlimentation en gaz Type de gazAltitudes supérieures à 10 000 pi 3048 m Raccordement au gazExigences concernant l’alimentation du brûleur Canalisation d’arrivée de gaz de la sécheuseEn cas d’utilisation du système d’évacuation existant ÉvacuationExigences concernant l’évacuation Le clapet de décharge doit être situé à au moins Installations d’évacuation facultativesAutres installations où le dégagement est réduit Planification du système d’évacuationTableau des systèmes d’évacuation Installation DES Pieds DE NivellementInstallation du système d’évacuation Déterminer l’itinéraire d’acheminement du conduitRaccordement DES Tuyaux D’ALIMENTATION Modèles À Vapeur Raccordement DU Conduit D’ÉVACUATIONLA Sécheuse Achever L’INSTALLATIONInversion de la gâche Réinstallation de la porteDépose de la porte Ouvrir la porte de la sécheuseAbsence de chaleur DépannageFonctionnement de la sécheuse Le sécheuse ne fonctionne pasLe filtre à charpie doit être nettoyé avant chaque charge La sécheuse est-elle installée dans un placard?Résultats de la sécheuse Le filtre à charpie est-il obstrué de charpie?Page W10261614A W10267631A SP