Maytag W10261614A, W10267631A-SP Installation Requirements, Tools and Parts, Optional Equipment

Page 4

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Optional Equipment

Refer to your Use and Care guide for information about the accessories available for your dryer.

For All Installations:

Flat-blade screwdriver

Adjustable wrench that opens to 1" (25 mm) or hex-head socket wrench (for adjusting dryer feet)

Level

Vent clamps

Knife

Gas Installations:

Caulking gun and compound (for installing new exhaust vent)

Tin snips (new vent installations)

1/4" nut driver (recommended)

Tape measure

Pliers

Location Requirements

8" or 10" pipe wrench

Pipe-joint compound

8" or 10" adjustable wrench

resistant to LP gas

 

 

(for gas connections)

 

Parts supplied

Non-Steam Models

4 Leveling legs

Steam Models

A

B

C

D

E

 

A. Leveling legs (4)

 

D. Inlet hose with right-angle

 

B. “Y” connector

 

connector

 

 

C. Short inlet hose

 

E. Rubber washer

 

Remove parts package from dryer drum. Check that all parts are included.

NOTE: Do not use leveling legs supplied with dryer if installing on a pedestal.

Parts needed

Check local codes. Check existing electrical supply and venting. See “Electrical Requirements” and “Venting Requirements” before purchasing parts.

Mobile home installations require metal exhaust system hardware available for purchase from the dealer from whom you purchased your dryer. For further information, please refer to the “Assistance or Service” section in your Use and Care Guide.

You will need

A location that allows for proper exhaust installation. See “Venting Requirements.”

A separate 30-amp circuit.

If you are using a power supply cord, a grounded electrical outlet located within 2 ft. (610 mm) of either side of the dryer. See “Electrical Requirements.”

A sturdy floor to support the total dryer weight of 200 lbs

(90.7 kg). The combined weight of a companion appliance should also be considered.

A level floor with a maximum slope of 1" (25 mm) under entire dryer. If slope is greater than 1" (25 mm), install Extended Dryer Feet Kit, Part Number 279810. Clothes may not tumble properly and automatic sensor cycles may not operate correctly if dryer is not level.

For a garage installation, you will need to place the dryer at least 18" (460 mm) above the floor. If using a pedestal, you will need 18" (460 mm) to the bottom of the dryer.

Steam models only: Cold water faucets located within 4 ft. (1.2 m) of dryer, and water pressure of 20-100 psi (137.9-689.6 kPa). Cold water supply may come from washer using “Y” connector provided.

Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end

of an automatic sensor cycle. This can result in longer drying times.

The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes,

or sleeping quarters. Contact your local building inspector.

4

Image 4
Contents Instructions D’INSTALLATION DE LA Sécheuse Table DES MatièresDryer Safety Your safety and the safety of others are very importantWhat to do if YOU Smell GAS Installation Requirements Tools and PartsOptional Equipment Location RequirementsDryer Dimensions Installation clearancesMobile home installations require Electrical Requirements Electric Dryer Power Hookup Canada onlyIt is your responsibility GAS Dryer Power Hookup Gas Supply RequirementsIf using an existing vent system VentingMake Gas Connection Venting RequirementsPlan Vent System If this is a new vent system Vent materialOptional exhaust installations Alternate installations for close clearancesVent system chart Determine vent pathInstall Leveling Legs Install Vent SystemConnect Inlet Hose Steam Models Connect VentLevel Dryer Complete InstallationReverse Door Swing Reinstall the door Reverse the strikeLoosen the top screw from each of the 2 hinges in Step Dryer door openingTroubleshooting Dryer OperationDryer will not run No heatDryer Results Is the lint screen clogged with lint?Are fabric softener sheets blocking the grille? Is the exhaust vent the correct length?Sécurité DE LA Sécheuse Votre sécurité et celle des autres est très importantePage Exigences D’INSTALLATION Exigences demplacementOutillage et pièces Équipement facultatifDimensions de la sécheuse ’installation dans une maison mobile exigeDégagements de séparation à respecter De décharge de la sécheuseSpécifications électriques Raccordement DE L’ALIMENTATION LA Sécheuse Électrique’est à l’utilisateur qu’incombe la responsabilité de Raccordement DE L’ALIMENTATION LA Sécheuse À GAZ Alimentation en gazType de gaz Canalisation d’arrivée de gazRaccordement au gaz Exigences concernant l’alimentation du brûleurCanalisation d’arrivée de gaz de la sécheuse Altitudes supérieures à 10 000 pi 3048 mExigences concernant l’évacuation ÉvacuationEn cas d’utilisation du système d’évacuation existant Installations d’évacuation facultatives Autres installations où le dégagement est réduitPlanification du système d’évacuation Le clapet de décharge doit être situé à au moinsInstallation DES Pieds DE Nivellement Installation du système d’évacuationDéterminer l’itinéraire d’acheminement du conduit Tableau des systèmes d’évacuationRaccordement DU Conduit D’ÉVACUATION Raccordement DES Tuyaux D’ALIMENTATION Modèles À VapeurAchever L’INSTALLATION LA SécheuseRéinstallation de la porte Dépose de la porteOuvrir la porte de la sécheuse Inversion de la gâcheDépannage Fonctionnement de la sécheuseLe sécheuse ne fonctionne pas Absence de chaleurLa sécheuse est-elle installée dans un placard? Résultats de la sécheuseLe filtre à charpie est-il obstrué de charpie? Le filtre à charpie doit être nettoyé avant chaque chargePage W10261614A W10267631A SP