Installation clearances

Mobile home - Additional installation requirements

The location must be large enough to allow the dryer door to open fully.

Dryer Dimensions

This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 MH.

431/2"

(1105 mm)

 

221/4"

291/4"

(565 mm)

(743 mm)

29"

(737 mm)

 

NOTE: Most installations require a minimum 5" (127 mm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”

Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 mm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:

Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door, and floor moldings.

Additional spacing should be considered on all sides of the dryer to reduce noise transfer.

For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.

 

 

 

14" máx.*

 

 

 

 

 

(356 mm)

48" 2*

 

18"*

 

 

 

(310 cm2)

3"*

 

 

 

 

(76 mm)

(457 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3"*

 

 

 

 

24" 2*

(76 mm)

 

 

 

 

 

 

 

 

 

(155 cm2)

 

1"

29"

1"

291/4"

5"

 

(25 mm)

(25 mm)

(127 mm)

 

(737 mm)

(743 mm)

 

Recessed

Side view- closet

Closet door

area

or confined area

with vents

Mobile home installations require:

All Dryers

Metal exhaust system hardware, which is available for purchase from your dealer.

Special provisions must be made in mobile homes to introduce outside air into dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.

For gas dryers

Mobile Home Installation Kit Part Number 346764. See “Tools and Parts” section for information on ordering.

5

Image 5
Contents Table DES Matières Instructions D’INSTALLATION DE LA SécheuseYour safety and the safety of others are very important Dryer SafetyWhat to do if YOU Smell GAS Tools and Parts Installation RequirementsOptional Equipment Location RequirementsMobile home installations require Installation clearancesDryer Dimensions It is your responsibility Electric Dryer Power Hookup Canada onlyElectrical Requirements Gas Supply Requirements GAS Dryer Power HookupVenting If using an existing vent systemMake Gas Connection Venting RequirementsIf this is a new vent system Vent material Plan Vent SystemAlternate installations for close clearances Optional exhaust installationsVent system chart Determine vent pathInstall Vent System Install Leveling LegsConnect Inlet Hose Steam Models Connect VentReverse Door Swing Complete InstallationLevel Dryer Reverse the strike Reinstall the doorLoosen the top screw from each of the 2 hinges in Step Dryer door openingDryer Operation TroubleshootingDryer will not run No heatIs the lint screen clogged with lint? Dryer ResultsAre fabric softener sheets blocking the grille? Is the exhaust vent the correct length?Votre sécurité et celle des autres est très importante Sécurité DE LA SécheusePage Exigences demplacement Exigences D’INSTALLATIONOutillage et pièces Équipement facultatif’installation dans une maison mobile exige Dimensions de la sécheuseDégagements de séparation à respecter De décharge de la sécheuse’est à l’utilisateur qu’incombe la responsabilité de Raccordement DE L’ALIMENTATION LA Sécheuse ÉlectriqueSpécifications électriques Alimentation en gaz Raccordement DE L’ALIMENTATION LA Sécheuse À GAZType de gaz Canalisation d’arrivée de gazExigences concernant l’alimentation du brûleur Raccordement au gazCanalisation d’arrivée de gaz de la sécheuse Altitudes supérieures à 10 000 pi 3048 mEn cas d’utilisation du système d’évacuation existant ÉvacuationExigences concernant l’évacuation Autres installations où le dégagement est réduit Installations d’évacuation facultativesPlanification du système d’évacuation Le clapet de décharge doit être situé à au moinsInstallation du système d’évacuation Installation DES Pieds DE NivellementDéterminer l’itinéraire d’acheminement du conduit Tableau des systèmes d’évacuationRaccordement DES Tuyaux D’ALIMENTATION Modèles À Vapeur Raccordement DU Conduit D’ÉVACUATIONLA Sécheuse Achever L’INSTALLATIONDépose de la porte Réinstallation de la porteOuvrir la porte de la sécheuse Inversion de la gâcheFonctionnement de la sécheuse DépannageLe sécheuse ne fonctionne pas Absence de chaleurRésultats de la sécheuse La sécheuse est-elle installée dans un placard?Le filtre à charpie est-il obstrué de charpie? Le filtre à charpie doit être nettoyé avant chaque chargePage W10261614A W10267631A SP