Emerson MAS 2600 user manual 75.0

Page 14

Installation & User Manual

Ed 19UK

June 2013

 

 

Amplifier Box MAS2600-XXX-XX-X/XX

The MAS2600 amplifier box is manufactured in polyester, which has the strength and stability of aluminium, insulation and resistance properties of plastics. Colour code RAL 7000.

The amplifier box is protected to the level of IP 56 and must be mounted outside the tank, e.g. in the engine room or other dry areas.

The amplifier box is available with a PG9 hole for silicone gel filling to protect the amplifier from moisture.

When the amplifier box is mounted on open deck with the risk of being drenched it is recommended to mount the amplifier box inside the deck box 165B9035. To further reduce the exposure of water place the amplifier box to the centre of the vessel.

0: Without amplifier box.

1: Standard box with PG 11/PG 11 cable glands. For cable diameter 5 -10 mm.

2:Standard box with PG 11/PG 13.5 cable glands. For cable diameter 6-12 mm.

3:Standard box with PG 11/PG 16 cable glands. For cable diameter 10-14 mm.

5:Standard box with PG 13.5/PG 13.5 cable glands. For cable diameter 6-12 mm.

6:Standard box with PG 11/PG 11 cable glands and filling hole. For cable diameter 5 -10 mm.

7:Standard box with PG 11/PG 13.5 cable glands and filling hole. For cable diameter 6-12 mm.

8:Standard box with PG 11/PG 16 cable glands and filling hole. For cable diameter 10-14 mm.

110.0

55.0

98.0

 

2600 SERIES

 

 

4-20 mA TWO WIRE TRANSMITTER

75.0

x EEX ia

C T5

S/N:

2600

CERTIFICATE REF.: 90-C.95948 Tamb.: -40 to +85 °C

 

Lint = 20 uH

Cint = 10 nF

Umax = 33 V

<

 

IK= 45 mA

 

 

 

MARINE AUTOMATION DENMARK

 

4 pcs. ø4.5

45.0

PG11 cable gland

1/8" NPT vent fitting

Use 4x20mm bolts and nuts for suspension on a 4mm thick surface

Page 14 of 28

Image 14
Contents MAS2600 Table of contents Application MAS2600 Tank Contents TransmitterDescription and Operation Technical Specifications MAS2600 Ordering Information Transducer RangesType Gauge TransmitterSelecting the Transducer Type Gauge and High Temperature Gauge TransducersSelecting the Measuring Range Transducer type 3.5 bar abs 2.0 bar absForepeak Tank Absolute TransducersBasic Rules Temperature Sensor MAS2600-XXX-XX-X/XX DraftBrackets for Internal Mounting drawing no. G022P010 Pole Mounting drawing no. G022P011Pipe End Mounting drawing no. G022P015 Flange Mounting drawing no. G022P013Flexible rubber tube mounting 80 ºC drawing no. G022P001 DN25 flange with 1 ball valve drawing no. G022P019 75.0 Deck Box 165B9035 Handling Installation June Intrinsically Safe Installation XXXXXX-YYYYEd 19UK Any 28V / 300R Testing and Recalibrating Testing= 12 mA Trd .range − + PCalculated output at atmospheric pressure Trouble Shooting Maintenance and Trouble ShootingMaintenance MAS2600 Test sheet FAXEmerson Process Management