Emerson MAS 2600 user manual Flexible rubber tube mounting 80 ºC drawing no. G022P001

Page 12

Installation & User Manual

Ed 19UK

June 2013

Flexible rubber tube mounting 80 ºC - drawing no. G022P001:

4-20 mA TWO WIRE TRANSMITTER

EE

CT5

S/N:

Tank top

H

Bulkhead

Tank bottom

A top flange made of SS 316L connected to rubber tube by a tightening clip using a special tool. The opposite hose end covers the transducer body and is fixed by a tightening clip.

NB: When ordering this mounting type always specify length for the measurement of H cf. above drawing.

Flexible PTFE tube mounting 125ºC - drawing no. G022P021:

4-20 mA TWO WIRE TRANSMITTER

EE

CT5

S/N:

Tank top

H

Bulkhead

Tank bottom

A top flange made of SS 316L connected to a Stainless Steel braided PTFE tube by fittings fixed to the tube by using special tools. A fitting in the opposite tube end is fixed to the transducer by means of nut and ferrules. Min. hose bending radius 130 mm.

NB: This mounting type cannot be used in hazardous area.

When ordering this mounting type always specify length for the measurement of H cf. above drawing.

Note: This mounting type can only be assembled by Emerson Process Management Marine Solutions, Damcos because it requires special tools. The customer can exchange the MAS2600 transmitter by ordering a G022B085 and a G022B082 together with the new MAS2600 transducer. It must clearly be specified that it is a replacement for an MAS2600 HXX-XX-P/XX.

Page 12 of 28

Image 12
Contents MAS2600 Table of contents MAS2600 Tank Contents Transmitter Description and OperationApplication Technical Specifications MAS2600 Ordering Information Transducer RangesType Gauge TransmitterGauge and High Temperature Gauge Transducers Selecting the Measuring RangeSelecting the Transducer Type Transducer type 3.5 bar abs 2.0 bar absAbsolute Transducers Basic RulesForepeak Tank Temperature Sensor MAS2600-XXX-XX-X/XX DraftBrackets for Internal Mounting drawing no. G022P010 Pole Mounting drawing no. G022P011Pipe End Mounting drawing no. G022P015 Flange Mounting drawing no. G022P013Flexible rubber tube mounting 80 ºC drawing no. G022P001 DN25 flange with 1 ball valve drawing no. G022P019 75.0 Deck Box 165B9035 Handling Installation June Intrinsically Safe Installation XXXXXX-YYYYEd 19UK Any 28V / 300R Testing and Recalibrating Testing= 12 mA Trd .range − + PCalculated output at atmospheric pressure Maintenance and Trouble Shooting MaintenanceTrouble Shooting MAS2600 Test sheet FAXEmerson Process Management