Emerson MAS 2600 user manual MAS2600 Test sheet, Fax

Page 27

 

Installation & User Manual

June 2013

Ed 19UK

MAS2600 Test sheet

ATT.:

Emerson Process Management

 

Marine Solutions

 

Damcos A/S, Service Department

FAX.:

+45 5578 7272

 

 

Name:

 

Ship name:

Yard:

NB No:

MAS2600:

Transducer serial no.:

 

 

 

 

 

Amplifier serial no.:

 

 

Tank name:

 

 

 

 

 

 

 

 

 

 

Liquid in tank

 

HFO:

 

DO:

 

 

 

 

Ballast:

 

Other:

The tank is

 

Full:

 

 

 

Empty:

 

Other:

 

Measurements:

 

 

 

 

 

 

 

 

 

 

 

1

Measure voltage between terminal

 

 

V DC

Voltage should be in the range 14 to 33 V DC.

 

5 and 6

 

 

 

Check power supply.

 

 

 

 

 

 

 

 

 

 

 

2

Measure ripple voltage between

 

 

V AC

Voltage must not exceed 2 V AC. Check power

 

terminal 5 and 6

 

 

 

supply.

 

 

 

 

 

 

 

 

 

 

 

3

Measure sensor excitation voltage

 

 

 

V DC

Voltage should be in the range 3.0 to 6.2 V DC

 

between terminal 7 and 10

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Measure sensor excitation voltage

 

 

mV DC

Voltage should be in the range -15 to 100 mV DC

 

between terminal 8 and 9

 

 

 

 

 

 

 

 

 

 

 

 

5

Measure current in supply lead to

 

 

 

 

 

Current should be in the range 4 to 20 mA and the

 

terminal 5

 

 

 

mA DC

same value as measured in point 6. If not the

 

 

 

 

 

 

 

 

 

amplifier may be defect.

6

Measure current in supply lead to

 

 

 

 

 

Current should be in the range 4 to 20 mA and the

 

terminal 6

 

 

 

mA DC

same value as measured in point 5. If not the

 

 

 

 

 

 

 

 

 

amplifier may be defect.

7

Measure sensor resistance with

 

 

 

 

 

If the resistance measured is less that 1 M Ohm the

 

sensor cable unconnected

 

 

 

 

 

sensor is defect.

 

 

 

Terminal 7 to cable shield

 

 

M Ohm

 

 

 

 

 

Terminal 8 to cable shield

 

 

M Ohm

 

 

 

 

 

Terminal 9 to cable shield

 

 

M Ohm

 

 

 

 

 

Terminal 10 to cable shield

 

 

M Ohm

 

 

 

 

8

Measure sensor bridge resistance

 

 

 

 

 

If the resistance measured is less than 1 K Ohm or

 

with sensor cable unconnected

 

 

 

 

 

greater that 50 K Ohm the sensor is defect.

 

Terminal 7 to Terminal 8

 

 

K Ohm

 

 

 

 

 

Terminal 7 to Terminal 9

 

 

K Ohm

 

 

 

 

 

Terminal 7 to Terminal 10

 

 

K Ohm

 

 

 

 

 

Terminal 8 to Terminal 9

 

 

K Ohm

 

 

 

 

 

Terminal 8 to Terminal 10

 

 

K Ohm

 

 

 

 

 

Terminal 9 to Terminal 10

 

 

K Ohm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

Visual inspection of the transmitter:

 

 

 

 

 

 

 

 

 

 

Is the cable damaged?

 

 

 

 

 

 

 

 

 

Are there sharp bends on the cable?

 

 

 

 

 

 

 

 

 

Are there moisture/liquids in the breather tube?

 

 

 

 

 

Is the diaphragm damaged?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

Comments:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 27 of 28

Image 27
Contents MAS2600 Table of contents MAS2600 Tank Contents Transmitter Description and OperationApplication Technical Specifications Transducer Ranges MAS2600 Ordering InformationGauge Transmitter TypeTransducer type 3.5 bar abs 2.0 bar abs Gauge and High Temperature Gauge TransducersSelecting the Measuring Range Selecting the Transducer TypeAbsolute Transducers Basic RulesForepeak Tank Draft Temperature Sensor MAS2600-XXX-XX-X/XXPole Mounting drawing no. G022P011 Brackets for Internal Mounting drawing no. G022P010Flange Mounting drawing no. G022P013 Pipe End Mounting drawing no. G022P015Flexible rubber tube mounting 80 ºC drawing no. G022P001 DN25 flange with 1 ball valve drawing no. G022P019 75.0 Deck Box 165B9035 Handling Installation June XXXXXX-YYYY Intrinsically Safe InstallationEd 19UK Any 28V / 300R Testing Testing and Recalibrating= 12 mA + P Trd .range −Calculated output at atmospheric pressure Maintenance and Trouble Shooting MaintenanceTrouble Shooting FAX MAS2600 Test sheetEmerson Process Management