Type

MAS2600-

 

XX-XX-X/XX

X

A: Absolute Transducer. The absolute transducer has no breather pipe, because it refers to absolute vacuum. An atmospheric pressure sensor is used to compensate for the atmospheric pressure. The absolute transducer is especially suitable for open deck applications, where the amplifier box may be exposed to flooding.

G: Gauge Transducer. The gauge transducer is fitted with a breather pipe at the back of the diaphragm to compensate for the atmospheric pressure. The breather pipe is connected to a vent plug in the amplifier box. The gauge transducer is suitable for most applications.

H: High Temperature Transducer. The high temperature transducer is available in gauge version only. The transducer is mounted with a special high temperature cable and designed for heated tanks e.g. HFO tanks, and other applications with high tank media temperatures. The transducer can be flange mounted or internally mounted.

Measuring Ranges MAS2600-XXX-XX-X/XX

Gauge Transmitter:

The MAS2600 Gauge Transmitter is supplied in 4 ranges. In the programmable amplifier the measuring range is divided into 8 sub-ranges and operated by means of the range select switch.

The transmitter output signal can be adjusted to 20 mA within the following sub-ranges.

 

 

 

 

Transducer type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

1

:

Type

2

:

 

Type

3

:

 

Type

4

:

Range No.

0 – 3.5 mH2O

0 – 7.0 mH2O

0 – 16.0 mH2O

0 – 35.0 mH2O

1

0.20 – 0.37 mH2O

0.20 – 0.30 mH2O

0.50

– 0.75 mH2O

1.00

– 1.90 mH2O

 

 

 

 

 

 

 

2

0.37 – 0.54 mH2O

0.30 – 0.50 mH2O

0.75

– 1.00 mH2O

1.90

– 2.80 mH2O

 

 

 

 

 

 

 

3

0.54 – 0.73 mH2O

0.50 – 0.70 mH2O

1.00

– 1.50 mH2O

2.80

– 3.90 mH2O

 

 

 

 

 

 

 

4

0.73 – 1.10 mH2O

0.70 – 1.10 mH2O

1.50

– 2.50 mH2O

3.90

– 5.80 mH2O

 

 

 

 

 

 

 

5

1.10 – 1.92 mH2O

1.10 – 1.80 mH2O

2.50

– 4.00mH2O

5.80

– 9.90 mH2O

 

 

 

 

 

 

6

1.92 – 3.10 mH2O

1.80 – 3.00 mH2O

4.00

– 6.00 mH2O

9.90 – 15.30 mH2O

 

 

 

 

 

 

7

3.10 – 3.50 mH2O

3.00 – 4.80 mH2O

6.00 – 10.00 mH2O

15.30

– 25.10 mH2O

 

 

 

 

 

 

 

 

 

 

 

 

 

8

NOT

4.80 – 7.10 mH2O

10.00

– 16.00 mH2O

25.10

– 35.60 mH2O

APPLICABLE

 

 

 

 

 

 

 

 

 

 

 

 

Page 6 of 28

Image 6
Contents MAS2600 Table of contents MAS2600 Tank Contents Transmitter Description and OperationApplication Technical Specifications MAS2600 Ordering Information Transducer RangesType Gauge TransmitterSelecting the Transducer Type Gauge and High Temperature Gauge TransducersSelecting the Measuring Range Transducer type 3.5 bar abs 2.0 bar absAbsolute Transducers Basic RulesForepeak Tank Temperature Sensor MAS2600-XXX-XX-X/XX DraftBrackets for Internal Mounting drawing no. G022P010 Pole Mounting drawing no. G022P011Pipe End Mounting drawing no. G022P015 Flange Mounting drawing no. G022P013Flexible rubber tube mounting 80 ºC drawing no. G022P001 DN25 flange with 1 ball valve drawing no. G022P019 75.0 Deck Box 165B9035 Handling Installation June Intrinsically Safe Installation XXXXXX-YYYYEd 19UK Any 28V / 300R Testing and Recalibrating Testing= 12 mA Trd .range − + PCalculated output at atmospheric pressure Maintenance and Trouble Shooting MaintenanceTrouble Shooting MAS2600 Test sheet FAXEmerson Process Management