Emerson MAS 2600 user manual Brackets for Internal Mounting drawing no. G022P010

Page 10

Installation & User Manual

Ed 19UK

June 2013

Brackets for Internal Mounting - drawing no. G022P010:

4-20 mA TWO WIRE TRANSMITTER

EE

CT5

S/N:

Tank top

38.0 Bulkhead

Tank bottom

55.0

125.0

160.0

40.0

45.0

The brackets are U-shaped and manufactured of 2 mm SS 316L plated steel. Diameter of mounting holes: 11.5 mm.

The transducer is secured by means of a spring fitted into two holes in the “U” shape, and can be mounted/dismounted without the use of tools.

When installing in hazardous areas the cable must be protected by a steel pipe welded to the tank.

Pole Mounting - drawing no. G022P011:

4-20 mA TWO WIRE TRANSMITTER

EE

CT5

S/N:

Tank top

 

Bulkhead

 

34.0

26.0

Tank bottom

 

40.0

1" Thread

24.0

 

26.0

41.0

The weldable collar and the nut are manufactured of SS 316L steel. The gaskets are made of nitrile rubber.

Note: Max torque 20 Nm (slightly tighten by the hand + 1/8-1/4 turn). Remember the gasket.

Page 10 of 28

Image 10
Contents MAS2600 Table of contents Description and Operation MAS2600 Tank Contents TransmitterApplication Technical Specifications MAS2600 Ordering Information Transducer RangesType Gauge TransmitterSelecting the Transducer Type Gauge and High Temperature Gauge TransducersSelecting the Measuring Range Transducer type 3.5 bar abs 2.0 bar absBasic Rules Absolute TransducersForepeak Tank Temperature Sensor MAS2600-XXX-XX-X/XX DraftBrackets for Internal Mounting drawing no. G022P010 Pole Mounting drawing no. G022P011Pipe End Mounting drawing no. G022P015 Flange Mounting drawing no. G022P013Flexible rubber tube mounting 80 ºC drawing no. G022P001 DN25 flange with 1 ball valve drawing no. G022P019 75.0 Deck Box 165B9035 Handling Installation June Intrinsically Safe Installation XXXXXX-YYYYEd 19UK Any 28V / 300R Testing and Recalibrating Testing= 12 mA Trd .range − + PCalculated output at atmospheric pressure Maintenance Maintenance and Trouble ShootingTrouble Shooting MAS2600 Test sheet FAXEmerson Process Management