| Installation & User Manual |
June 2013 | Ed 19UK |
|
|
Draft:
Vent pipe min. 1”
MAS2600 amplifier box
Weather deck
Min. draft |
Class approved Sea valve
EE | CT5 | S/N: |
Sensor pos. above
Ships hull
Ships hull
Transducer measuring range > max. draft minus sensor position.
This rule applies provided the transducer is mounted in accordance with the installation drawing for draft transmitters (vent pipe min. 1"). The sensor may be mounted direct on the sea valve with an air release valve if the ship is sailing in calm waters.
If the transducer is installed in tanks which may have excessive dynamic stresses such as e.g. high pump pressure, long bottomed tanks with a risk of slashing etc., contact Emerson Process Management Marine Solutions, Damcos.
Temperature Sensor MAS2600-XXX-XX-X/XX
The transducer can be supplied with a
0:Without temperature sensor.
1:With temperature sensor
Cable
Two types of transducer cable is available. The standard cable for applications with temperatures never exceeding 80°C, and high temperature cable for applications with temperatures up to 125°C. The transducer cable is delivered in whole meters.
For further information require data sheet.
To make the MAS2600 transmitter easy to install, and for later service purposes, the transducer cable should be as short as possible, though considering the position of the transducer and amplifier box.
Max. cable length: 300 m.
When installing in hazardous areas max. cable length: 75 m.
Page 9 of 28