Emerson MAS 2600 user manual Draft, Temperature Sensor MAS2600-XXX-XX-X/XX

Page 9

 

Installation & User Manual

June 2013

Ed 19UK

 

 

Draft:

Vent pipe min. 1”

MAS2600 amplifier box

Weather deck

Min. draft

Class approved Sea valve

4-20 mA TWO WIRE TRANSMITTER

EE

CT5

S/N:

Sensor pos. above

Ships hull

Ships hull

Transducer measuring range > max. draft minus sensor position.

This rule applies provided the transducer is mounted in accordance with the installation drawing for draft transmitters (vent pipe min. 1"). The sensor may be mounted direct on the sea valve with an air release valve if the ship is sailing in calm waters.

If the transducer is installed in tanks which may have excessive dynamic stresses such as e.g. high pump pressure, long bottomed tanks with a risk of slashing etc., contact Emerson Process Management Marine Solutions, Damcos.

Temperature Sensor MAS2600-XXX-XX-X/XX

The transducer can be supplied with a built-in Pt100 temperature sensor. The temperature sensor will only give a proper reading, if the transducer is an internally mounted type.

0:Without temperature sensor.

1:With temperature sensor

Cable MAS2600-XXX-XX-X/XX

Two types of transducer cable is available. The standard cable for applications with temperatures never exceeding 80°C, and high temperature cable for applications with temperatures up to 125°C. The transducer cable is delivered in whole meters.

For further information require data sheet.

To make the MAS2600 transmitter easy to install, and for later service purposes, the transducer cable should be as short as possible, though considering the position of the transducer and amplifier box.

Max. cable length: 300 m.

When installing in hazardous areas max. cable length: 75 m.

Page 9 of 28

Image 9
Contents MAS2600 Table of contents MAS2600 Tank Contents Transmitter Description and OperationApplication Technical Specifications Transducer Ranges MAS2600 Ordering InformationGauge Transmitter TypeSelecting the Measuring Range Gauge and High Temperature Gauge TransducersSelecting the Transducer Type Transducer type 3.5 bar abs 2.0 bar absAbsolute Transducers Basic RulesForepeak Tank Draft Temperature Sensor MAS2600-XXX-XX-X/XXPole Mounting drawing no. G022P011 Brackets for Internal Mounting drawing no. G022P010Flange Mounting drawing no. G022P013 Pipe End Mounting drawing no. G022P015Flexible rubber tube mounting 80 ºC drawing no. G022P001 DN25 flange with 1 ball valve drawing no. G022P019 75.0 Deck Box 165B9035 Handling Installation June XXXXXX-YYYY Intrinsically Safe InstallationEd 19UK Any 28V / 300R Testing Testing and Recalibrating= 12 mA + P Trd .range −Calculated output at atmospheric pressure Maintenance and Trouble Shooting MaintenanceTrouble Shooting FAX MAS2600 Test sheetEmerson Process Management