Installation & User Manual

Ed 19UK

June 2013

If the amplifier box is installed in an area with over pressure or negative pressure in relation to the atmospheric pressure in the tank, the breather tube must be directed to an area with atmospheric pressure equalling the pressure inside the tank. This applies to gauge transmitters only. For absolute transmitters this has no affect, due to the reference to absolute vacuum and not atmospheric pressure. This is also the reason why no breather tube is necessary.

Be sure that the cable glands are tight. Use a torque of 6 Nm.

Shield bracket

Do not fasten to tight

Transducer cable

Breather tube

1/8” NPT fitting for breather tube

Terminal block for Pt100

Breather hose

4-20 mA signal cable

element

 

 

Page 18 of 28

Image 18
Contents MAS2600 Table of contents MAS2600 Tank Contents Transmitter Description and OperationApplication Technical Specifications MAS2600 Ordering Information Transducer RangesType Gauge TransmitterSelecting the Transducer Type Gauge and High Temperature Gauge TransducersSelecting the Measuring Range Transducer type 3.5 bar abs 2.0 bar absAbsolute Transducers Basic RulesForepeak Tank Temperature Sensor MAS2600-XXX-XX-X/XX DraftBrackets for Internal Mounting drawing no. G022P010 Pole Mounting drawing no. G022P011Pipe End Mounting drawing no. G022P015 Flange Mounting drawing no. G022P013Flexible rubber tube mounting 80 ºC drawing no. G022P001 DN25 flange with 1 ball valve drawing no. G022P019 75.0 Deck Box 165B9035 Handling Installation June Intrinsically Safe Installation XXXXXX-YYYYEd 19UK Any 28V / 300R Testing and Recalibrating Testing= 12 mA Trd .range − + PCalculated output at atmospheric pressure Maintenance and Trouble Shooting MaintenanceTrouble Shooting MAS2600 Test sheet FAXEmerson Process Management