Dell E02B owner manual

Page 85

Steps

1.Loosen the two retention screws on the hard-drive/SSD backplane cable connector and lift it away from the PCIe extender/storage controller card.

CAUTION: To prevent damage to the PCIe extender/storage controller card, you must hold the card only by its edges.

2.Lift the PCIe extender/storage controller card up and away from the system.

Figure 33. Removing and installing the PCIe extender/storage controller card

1.

retention screw (2)

2. slot on the PCIe extender/storage

 

 

controller card

3.

tab on the PCIe extender/storage

4. standoff (2)

 

controller card support bracket

 

Next steps

1.Install the PCIe extender/storage controller card. See Installing the PCIe extender/storage controller card.

2.Install the following:

a.hard-drive/SSD cage

b.hard-drive/SSD backplane

c.hard drives/SSDs

85

Image 85
Contents Dell PowerEdge FC630 Page Contents Installing and removing sled components Troubleshooting your system Jumpers and connectors 104 Using System Diagnostics 102Technical specifications 107 Getting help 112 About your system Front-panel features and indicatorsHard-drive/SSD indicator patterns Using USB diskette or USB DVD/CD drivesHard-drive/SSD indicators IDRAC Direct LED indicator codesIDRAC Direct LED indicator Documentation matrix Quick Resource Locator Setting up and configuring the iDRAC IP address Setting up your systemLogging in to iDRAC Installing the operating system Page Navigation keys About System SetupSystem Setup Main Menu Entering System SetupSystem Bios screen System Memory screen System Information screenATS Processor Settings screenSata Settings screen Post Page Network Settings screen Boot Settings screenIntegrated Devices screen Serial Communication screen C1E System Profile Settings screenSystem Security Settings screen Secure Boot Custom Policy Settings screen Miscellaneous Settings screenPage About Dell Lifecycle Controller Changing the boot order About Boot ManagerEntering Boot Manager Boot Manager main menuAssigning a system and/or setup password Choosing the system boot modeUsing your system password to secure your system IDRAC Settings utility Operating with a setup password enabledEmbedded systems management Entering the iDRAC Settings utility Recommended tools Safety instructionsBefore working inside your system After working inside your systemRemoving the sled Removing and installing a sledO connector cover Removing and installing the sled Installing the sledNDC Inside the sledRemoving the cooling shroud Cooling shroudProcessor/DIMM blank Installing the cooling shroudRemoving a processor/DIMM blank Removing and installing a processor/DIMM blank Installing a processor/DIMM blankLrdimm System memoryProcessor General memory-module installation guidelines Advanced ECC Lockstep Mode-specific guidelinesSample memory configurations Memory configurations two processors Removing memory modules Removing the memory module Installing memory modulesRemoving a PCIe mezzanine card PCIe mezzanine cardRemoving and installing a PCIe mezzanine card Idsdm card optional Installing a PCIe mezzanine cardReplacing an SD card Ensure that you read the Safety instructions Replacing an SD card Internal USB keyReplacing the internal USB key Removing the Idsdm card Removing and installing the Idsdm cardInstalling the Idsdm card Removing the rSPI card RSPI card optionalSD vFlash card Installing the rSPI cardReplacing the SD vFlash card Removing the Network Daughter Card Network Daughter CardInstall the NDC. See Installing the Network Daughter Card Processors Installing the Network Daughter CardRemoving a processor Installing and removing a heat sink Processor shield opening and closing lever sequence Installing and removing a processor Installing a processorPage Applying thermal grease on the top of the processor Hard drives/SSDs Hard drive/SSD installation guidelinesHard-drive/SSD bay numbering Removing a hard drive/SSD Removing and installing a hard drive/SSDRemoving a hard-drive/SSD blank Installing a hard drive/SSDHard-drive/SSD blank Release latch Shutdown procedure for servicing a hard drive/SSD Installing a hard-drive/SSD blankConfiguring the boot drive Hard drive/SSD Removing a 1.8 inch SSD from a 1.8 inch SSD carrier Removing the hard-drive/SSD cage Installing a 1.8 inch SSD in a 1.8 inch SSD carrierRemoving and installing a hard-drive/SSD cage Installing the hard-drive/SSD cageRemoving the hard-drive/SSD backplane Hard-drive backplaneRemoving and installing the hard-drive/SSD backplane Installing the hard-drive/SSD backplane Removing a Perc H730P slim card Perc H730P slim cardRemoving and installing a Perc H730P slim card Installing a Perc H730P slim cardRemoving the PCIe extender/storage controller card Storage controller cardPage Installing the PCIe extender/storage controller card Replacing the Nvram backup battery Nvram backup batteryReplacing the Nvram backup battery Removing the system board System boardPage Hex nut screw System board Screw Installing the system board Restoring the Service Tag using Easy Restore Trusted Platform Module Installing the Trusted Platform ModuleRe-enabling the TPM for TXT users Re-enabling the TPM for BitLocker usersTroubleshooting your system Troubleshooting USB devices Troubleshooting hard drivesTroubleshooting Solid State Drives Troubleshooting processors Troubleshooting an internal SD cardTroubleshooting the Nvram backup battery Troubleshooting the system boardSystem messages Diagnostic messagesAlert messages When to use the Embedded System Diagnostics Dell Embedded System DiagnosticsRunning the Embedded System Diagnostics System diagnostics controls Running Embedded System Diagnostics from an external mediaSystem board jumper settings Jumpers and connectorsCPU1 System board connectorsDisabling a forgotten password Technical specifications USB Per ISO 14644-1 with a 95% upper confidence 110 Page Contacting Dell Locating your system Service TagDocumentation feedback 113