StreamLight VF-PS1 Operation panel, LCD panel, To 5 F1 to F4 function keys, ESC key, FWD/REV key

Page 9

E6581429

QOperation panel

Totally enclosed box type VF-PS1 series have a special operation panel.

(2)(3) (4) (5)

(1)

1

(9)

 

 

(6)

 

(8)

 

 

(7)

 

 

(10)

(1): LCD panel

For explanation of windows displayed, see the next page.

(2) to (5): [F1] to [F4] function keys

The function of each function key varies depending on the window currently displayed.

Refer to the next page and “6. List of function key functions”

(6): [ESC] key

Each time this key is pressed, modes change from one to another. Also, pressing this key brings you back to the window one level higher in the window hierarchy.

(7): [FWD/REV] key

Each time this key is pressed, the direction of operation changes between forward run and reverse run. (To use this key, parameter settings need to be changed. Refer to the next page.)

(8): [RUN] key

The drive starts operation.

(To use this key, parameter settings need to be changed. Refer to the nest page.)

(9): [STOP/RESET] key The drive stops operation.

(To use this key, parameter settings need to be changed. Refer to the next page.) In case the inverter has tripped, pressing this key twice in a row resets the inverter.

*If multiple commands are entered by pressing the three keys [F2], [F3] and [F4] or [ESC], [FWD] and [RUN] in rapid succession, a stop command will be issued instead to stop operation.

(10): Control dial

In a menu window, turn the dial clockwise or counterclockwise to select a menu item (the item selected is highlighted) and press the dial to confirm the menu item selected.

Turn the dial clockwise (+) to select an item that follows the item currently selected.

Turn the dial counterclockwise (-) to select an item that precedes the item currently selected.

Selecting a menu item by turning the dial clockwise or counterclockwise and confirm the item selected by pressing the dial are referred to as “select/confirm an item.”

In a value setting window, turn the dial clockwise or counterclockwise to increment or decrement the value displayed, and press the dial to confirm the value specified.*1

Turn the dial clockwise (+) to increment the value.

Turn the dial counterclockwise (-) to decrement the value.

Turning the dial clockwise or counterclockwise to increment or decrement the value displayed and pressing the dial to confirm the value specified are referred to as “specify/confirm a value.”

*1: Some settings are executed only by tuning the control dial.

A-3

Image 9
Contents Tosverttm VF-PS1 Page Transportation & installation Safety precautionsII. Introduction Contents Page Read first Contents of the product codeCheck the product This manual E6581386Names and functions Outside view Structure of the main bodyOperation panel STOP/RESET key The drive stops operationLCD panel To 5 F1 to F4 function keysFWD About changing parameter settingsMain circuit terminal VFPS1-4037PDE, 4055PDE VFPS1-4150PLE PO PA/+ PE PO PA/+ PB PC/- PE PA/+ Front cover Detaching the coverGrounding capacitor switching method Charge lampVFPS1-4007PLE~4220PLE VFPS1-4300PLE~4900PLE Case of adopting external braking resistor OptionalHow to install Installation Installation environmentConnection of equipment Standard connections Standard connection diagram sink logicStandard connection diagram source logic Description of terminals Power supply and motor connectionsMain circuit terminals Connection with peripheral equipmentSettings to be made at first power on OperationsLanguage Selection window appears Top View Mode Setting/monitor modesParameter Setup Mode Status Monitor ModeSetting a panel operation frequency Operation in Top View ModePress the control dial Explanation of the top windowUsing an Easy key function Press the F2 Lng key Selecting a language to be displayedSelect/confirm the desired language with the control dial Performing jog runPress the STOP/RESET key Emergency stop / reset operationThen press the STOP/RESET key again Press the F4 key to carry out jog runSelect/confirm History function using the control dial Searching and setting parametersWhen Quick mode is selected This window, settings can be changedSelect/confirm Basic parameters using the control dial Setting a basic parameterEx. Select/confirm Command input mode and Base frequency F1 F2 F3Setting an extended parameter Select/confirm Extended parameters using the control dialChange the parameter setting CMOd Select/confirm Changed Parameters using the control dialItems displayed Description Display of details Monitoring the operation statusDisplaying details of an item monitored Select/confirm the desired item using the control dialFunction key Display Reference Position List of function key functionsPage How to cope with the CE standards Measures to satisfy the standardsMeasures to satisfy the EMC directive RES, PWR, no Ex. Countermeasure inverter wiring PLE typePDE typeWiring port plate PLE type PDE type Conforming to UL Type Measurements to be taken to satisfy the UL/CSA standardsSelection of peripheral devices Selection of wiring materials and devicesRated current a AC-1 Selection of wiring equipmentPWM Table of parametersPage Models and their standard specifications SpecificationsOverleaf LCD Outside dimensions and mass Outside dimensions and weightOutline drawing Fig. C Fig. G