QWiring port plate

PLE – type

PDE - type

 

A

B

C

D

E

F

G

H

J

 

 

 

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

 

 

4007PLE~4022PLE

97.5

97.5

84

91.5

83

74

20.5

25.5

16.5

 

 

(20.7)

(22.8)

(18.8)

 

 

 

 

 

 

 

 

 

 

 

4037PLE, 4055PLE

111.5

111.5

84

91.5

83

74

20.5

25.5

16.5

 

 

(20.7)

(22.8)

(18.8)

 

 

 

 

 

 

 

 

 

 

 

4075PLE, 4110PLE

117.9

117.9

78.5

86.5

98

93

20.5

25.5

16.5

 

 

(20.7)

(22.8)

(18.8)

 

 

 

 

 

 

 

 

 

 

 

4150PLE

148.2

141.2

84

78.8

132

132

32.5

25.5

16.5

 

 

(37.4)

(28.6)

(18.8)

 

 

 

 

 

 

 

 

 

 

 

4185PLE, 4220PLE

155.2

148.2

80

88.8

132

144

32.5

32.5

16.5

 

 

(37.4)

(28.6)

(18.8)

 

 

 

 

 

 

 

 

 

 

 

4300PLE

158.4

158.4

84

73.8

141

139

40.5

40.5

16.5

 

 

(47.5)

(37.4)

(18.8)

 

 

 

 

 

 

 

 

 

 

 

4370PLE, 4450PLE

167.5

167.5

96

76.8

141

138

50.5

40.5

16.5

 

7

(47.5)

(37.4)

(18.8)

 

 

 

 

 

 

 

 

 

4550PLE~4900PLE

189

191

97

69.5

207

228

63.5

50.5

16.5

 

(60.5)

(47.5)

(18.8)

 

4007PDE~4022PDE

175.5

97.5

84

44.5

130

121

20.5

25.5

16.5

 

 

(20.7)

(22.8)

(18.8)

 

 

 

 

 

 

 

 

 

 

 

4037PDE, 4055PDE

189.5

111.5

84

44.5

130

121

32.5

25.5

16.5

 

 

(20.7)

(22.8)

(18.8)

 

 

 

 

 

 

 

 

 

 

 

4075PDE, 4110PDE

192.9

117.9

78.5

56.5

128

123

32.5

25.5

16.5

 

 

(20.7)

(22.8)

(18.8)

 

 

 

 

 

 

 

 

 

 

 

4150PDE

233.2

141.2

84

73.8

137

137

32.5

25.5

16.5

 

 

(37.4)

(28.6)

(18.8)

 

 

 

 

 

 

 

 

 

 

 

4185PDE, 4220PDE

240.2

148.2

80

88.8

132

144

32.5

32.5

16.5

 

 

(37.4)

(28.6)

(18.8)

 

 

 

 

 

 

 

 

 

 

 

4300PDE

226.5

158.5

84

74

141

139

40.5

40.5

16.5

 

 

(47.5)

(37.4)

(18.8)

 

 

 

 

 

 

 

 

 

 

 

4370PDE, 4450PDE

251.5

167.5

96

76.8

141

138

50.5

40.5

16.5

 

 

(47.5)

(37.4)

(18.8)

 

 

 

 

 

 

 

 

 

 

 

4550PDE~4900PDE

271

191

97

106

170.5

191.5

63.5

50.5

16.5

 

 

(60.5)

(47.5)

(18.8)

 

 

 

 

 

 

 

 

 

 

 

Note) Values in ( ) are for UL Type 12 conformity type. Drives with UL Type 12 conformity are optional. Contact your nearest Toshiba inverter distributor for them.

G-3

Image 41
Contents Tosverttm VF-PS1 Page Transportation & installation Safety precautionsII. Introduction Contents Page Read first Contents of the product codeCheck the product This manual E6581386Names and functions Outside view Structure of the main bodyOperation panel STOP/RESET key The drive stops operationLCD panel To 5 F1 to F4 function keysFWD About changing parameter settingsMain circuit terminal VFPS1-4037PDE, 4055PDE VFPS1-4150PLE PO PA/+ PE PO PA/+ PB PC/- PE PA/+ Front cover Detaching the coverVFPS1-4007PLE~4220PLE Grounding capacitor switching methodCharge lamp VFPS1-4300PLE~4900PLE Case of adopting external braking resistor OptionalHow to install Installation Installation environmentConnection of equipment Standard connections Standard connection diagram sink logicStandard connection diagram source logic Description of terminals Power supply and motor connectionsMain circuit terminals Connection with peripheral equipmentLanguage Selection window appears Settings to be made at first power onOperations Top View Mode Setting/monitor modesParameter Setup Mode Status Monitor ModeSetting a panel operation frequency Operation in Top View ModePress the control dial Explanation of the top windowUsing an Easy key function Press the F2 Lng key Selecting a language to be displayedSelect/confirm the desired language with the control dial Performing jog runPress the STOP/RESET key Emergency stop / reset operationThen press the STOP/RESET key again Press the F4 key to carry out jog runSelect/confirm History function using the control dial Searching and setting parametersWhen Quick mode is selected This window, settings can be changedSelect/confirm Basic parameters using the control dial Setting a basic parameterEx. Select/confirm Command input mode and Base frequency F1 F2 F3Change the parameter setting Setting an extended parameterSelect/confirm Extended parameters using the control dial CMOd Select/confirm Changed Parameters using the control dialItems displayed Description Display of details Monitoring the operation statusDisplaying details of an item monitored Select/confirm the desired item using the control dialFunction key Display Reference Position List of function key functionsPage Measures to satisfy the EMC directive How to cope with the CE standardsMeasures to satisfy the standards RES, PWR, no Ex. Countermeasure inverter wiring PLE typePDE typeWiring port plate PLE type PDE type Conforming to UL Type Measurements to be taken to satisfy the UL/CSA standardsSelection of peripheral devices Selection of wiring materials and devicesRated current a AC-1 Selection of wiring equipmentPWM Table of parametersPage Models and their standard specifications SpecificationsOverleaf LCD Outline drawing Outside dimensions and massOutside dimensions and weight Fig. C Fig. G