StreamLight VF-PS1 instruction manual Read first, Check the product, Contents of the product code

Page 7

E6581429

1.Read first

1.1Check the product

Type indication

Inverter main unit

Name plate

VF-PS13PH-200/240V 0.75kW/1HP

Series name Power supply Motor capacity

Carton box

Type indication

Warning label

Name plate

Operation panel

*1)

Type indication label

1

Instruction manuals (2 volumes)

 

 

 

 

Warning label

 

This manual

E6581386

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DANGER

 

 

 

 

Risk of injury, electric shock or fire.

 

 

 

 

Read the Instruction Manual.

 

 

 

 

Do not open the cover while power is applied or

 

 

 

 

for 15 minutes after power has been removed.

 

 

 

 

Ensure proper earth connection.

Inverter Type Applicable motor

Invert rated output capacity Power supply

Related input current Related output current Serial No.

*1): Operation panel is not attached to the inverter main unit at the delivery. Refer to 1.3.1 and attach the panel to the unit before installing the inverter.

1.2 Contents of the product code

Explanation of the type and form written on the label.

TypeFormSpecial specification code

V F P S 1 - 4 0 0 7 P L E - W N - A 2 2

Model name

TOSVERT

VF-PS1 series

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage class

 

Applicable motor capacity

Operation panel

 

Additional functions I

 

Additional functions II

 

 

Special

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

specification code

4: 380V~480V

 

004:0.4kW

185:18.5kW

P: Provided

 

L: Built-in EMC filter

 

E: Totally enclosed

 

 

 

 

 

 

 

007:0.75kW

220:22kW

 

 

 

 

 

(class A)

 

 

box type

 

 

A††: Special

 

 

015:1.5kW

300:30kW

 

 

 

 

+

 

 

 

 

Y: Others

 

 

specification code

 

 

 

 

 

 

 

basic filter

 

 

 

 

 

022:2.2kW

370:37kW

 

 

 

 

 

 

 

(non-standard)

 

 

(††is a number)

 

 

 

 

 

 

D: Built-in EMC filter

 

 

 

 

 

 

037:3.7kW

450:45kW

 

 

 

 

 

(class B)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

055:5.5kW

550:55kW

 

 

 

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

075:7.5kW

750:75kW

 

 

 

 

 

basic filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

110:11kW

900:90kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default interface

 

 

 

 

150:15kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

logic (*1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WN: Negative

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WP: Positive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1): This code represents the factory default logic setting. You can switch from one input/output logic to the other using slide switch SW1. For more details, refer to the manual E6581386 Section 2.3.2.

A-1

Image 7
Contents Tosverttm VF-PS1 Page Transportation & installation Safety precautionsII. Introduction Contents Page This manual E6581386 Contents of the product codeRead first Check the productNames and functions Outside view Structure of the main bodyTo 5 F1 to F4 function keys STOP/RESET key The drive stops operationOperation panel LCD panelFWD About changing parameter settingsMain circuit terminal VFPS1-4037PDE, 4055PDE VFPS1-4150PLE PO PA/+ PE PO PA/+ PB PC/- PE PA/+ Front cover Detaching the coverCharge lamp Grounding capacitor switching methodVFPS1-4007PLE~4220PLE VFPS1-4300PLE~4900PLE Case of adopting external braking resistor OptionalHow to install Installation Installation environmentConnection of equipment Standard connections Standard connection diagram sink logicStandard connection diagram source logic Connection with peripheral equipment Power supply and motor connectionsDescription of terminals Main circuit terminalsOperations Settings to be made at first power onLanguage Selection window appears Status Monitor Mode Setting/monitor modesTop View Mode Parameter Setup ModeExplanation of the top window Operation in Top View ModeSetting a panel operation frequency Press the control dialUsing an Easy key function Performing jog run Selecting a language to be displayedPress the F2 Lng key Select/confirm the desired language with the control dialPress the F4 key to carry out jog run Emergency stop / reset operationPress the STOP/RESET key Then press the STOP/RESET key againThis window, settings can be changed Searching and setting parametersSelect/confirm History function using the control dial When Quick mode is selectedF1 F2 F3 Setting a basic parameterSelect/confirm Basic parameters using the control dial Ex. Select/confirm Command input mode and Base frequencySelect/confirm Extended parameters using the control dial Setting an extended parameterChange the parameter setting CMOd Select/confirm Changed Parameters using the control dialItems displayed Description Display of details Monitoring the operation statusDisplaying details of an item monitored Select/confirm the desired item using the control dialFunction key Display Reference Position List of function key functionsPage Measures to satisfy the standards How to cope with the CE standardsMeasures to satisfy the EMC directive RES, PWR, no Ex. Countermeasure inverter wiring PLE typePDE typeWiring port plate PLE type PDE type Conforming to UL Type Measurements to be taken to satisfy the UL/CSA standardsSelection of peripheral devices Selection of wiring materials and devicesRated current a AC-1 Selection of wiring equipmentPWM Table of parametersPage Models and their standard specifications SpecificationsOverleaf LCD Outside dimensions and weight Outside dimensions and massOutline drawing Fig. C Fig. G