Furuno DS-60 installation manual Installation Manual, Iii

Page 1

 

 

Installation Manual

 

 

DOPPLER SONAR

 

 

 

DS-60

 

 

SAFETY INSTRUCTIONS

i

SYSTEM CONFIGURATION

ii

EQUIPMENT LISTS

iii

1.

INSTALLATION

1-1

 

1.1

Display Unit DS-600

1-1

 

1.2

Transceiver Unit DS-620

1-4

 

1.3

Distributor Unit DS-610

1-5

 

1.4

Transducer

1-6

 

1.5

Junction Box DS-640 (option)

1-16

 

1.6

Installation of Display Unit with DS-605 (Water Proof Box, option)

1-17

 

1.7

Remote Controller RD-501/Dimmer Controller RD-502 (option)

1-20

 

1.8

Rate-of-Turn Gyro DS-340 (option)

1-21

2.

WIRING

2-1

 

2.1

Distributor Unit DS-610

2-2

 

2.2

Transceiver Unit DS-620

2-5

2.3Display Unit DS-600, Remote Controller RD-501/Dimmer Controller RD-502 (option)

...................................................................................................................................

2-6

2.4 Junction Box DS-640 (option)

2-8

3. MENU SETTINGS

3-1

3.1

How to Use the Service Menu

3-1

3.2

How to Set the System Menu

3-3

APPENDIX 1 CALIBRATION

AP-1

APPENDIX 2 JIS CABLE GUIDE

AP-4

PACKING LISTS

A-1

OUTLINE DRAWINGS

D-1

INTERCONNECTION DIAGRAM

S-1

www.furuno.co.jp

All brand and product names are trademarks, registered trademarks or service marks of their respective holders.

Image 1
Contents Iii Installation Manual00017233810 Safety Instructions System Configurations Standard supply Equipment ListsOptional Supply Mounting consideration Display Unit DS-600Flush mount Desktop or table underside mount Hanger assembly Type OP26-8, Code NoHow to set the cosmetic cap and alarm lid assy Transceiver Unit DS-620 Installation considerationsDistributor Unit DS-610 Transducer Installation locationTransducer tank DS-660, sectional view Installation using the transducer tank DS-660Hex. bolt 15 Seal washer Fixing plate Hex. bolt M6x20 Spring washer M6 Cable assy Metal fixing Transducer tank, sectional view DS-661 gate valve, sectional view Installation with gate valve DS-661Installation Installation Installation How to open the gate valve Junction Box DS-640 option Mounting considerations Mounting procedureApply silicon rubber to M10 bolts as shown below Pass the cable through the cable gland as shown below How to change orientation of the front cover of DS-605 Remote Controller RD-501/Dimmer Controller RD-502 optionRate-of-Turn Gyro DS-340 option Leveling adjustmentThis page is intentionally left blank Precautions for cable installation WiringTop cover Cable clamps, entrances Connection of Wago connectorTB3 TB1 TB5 TB2 TB4 TB8 DS-610 Distributor Unit DS-620 Transceiver unit DS-600 Display unit DS-600, example of connection DS-640 Junction Box Junction Box DS-640, optionHow to Use the Service Menu Menu SettingsMenu item Meaning Option How to show the System menu How to Set the System MenuHow to set ship’s data Meaning Setting range How to enter offset valuesHow to correct the ship’s speed This page is intentionally left blank Milepost run AP-1Calculation with transit posts Calculation with DS-60 AP-2AP-3 AP-4 Appendix 2 JIS Cable Guide+/05+105+0&4#9+014440%10. #% #6 #6 52#42#465.+5614 5 #%%5514+5 Page Page Page Dec/08 R.Esumi Mar/09 R.Esumi Dec/08 R.Esumi 14/Jul/09 R.Esumi 14/Jul/09 R.Esumi 26/Oct/09 R.Esumi Dec/08 R.Esumi Dec/08 R.Esumi Dec/08 R.Esumi Doppler Sonar