Furuno installation manual Display Unit DS-600, Mounting consideration, Flush mount

Page 7

1.INSTALLATION

NOTICE

Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment.

Those items contain organic solvents that can damage coating and plastic parts, especially plastic connectors.

1.1Display Unit DS-600

Mounting consideration

The display unit can be installed on a desktop, on the underside of a table, or flush mounted in a panel. When you select a mounting location, keep in mind the following points:

Locate the display unit away from exhaust pipes and vents.

Select an installation location that is well ventilated.

Locate the display unit where shock and vibration are minimal.

Allow enough maintenance space at the sides and rear of the display unit and leave enough slack in cables to facilitate maintenance and servicing.

Observe the compass safe distances (see page i) to prevent the interference to a magnetic compass.

The nominal viewing distance for the display unit is 1 m. Select a suitable mounting location considering that distance.

Flush mount

See the outline drawing in the back of this manual. Before you fasten the display unit to the cutout, first connect the cables referring to chapter 2.

1. Make a cutout in the mounting location as shown in the illustration below.

223+0.5 (8.78”)

18 (0.71”)

228+1 (8.98”) (for outdoor)

232+1 (9.13”)

(for indoor)

223+0.5 (8.78”)

228+1 (8.98”)

(for outdoor)

240 (9.45”)

232+1 (9.13”) (for indoor)

12 (0.47”)

78 (3.07”)

240 (9.45”)

Pilot hole

18 (0.71”) or

22 (0.87”)

Fixing hole (4- 6)

(four places)

(for outdoor)

(for indoor)

 

1-1

Image 7
Contents Iii Installation Manual00017233810 Safety Instructions System Configurations Standard supply Equipment ListsOptional Supply Mounting consideration Display Unit DS-600Flush mount Desktop or table underside mount Hanger assembly Type OP26-8, Code NoHow to set the cosmetic cap and alarm lid assy Transceiver Unit DS-620 Installation considerationsDistributor Unit DS-610 Transducer Installation locationTransducer tank DS-660, sectional view Installation using the transducer tank DS-660Hex. bolt 15 Seal washer Fixing plate Hex. bolt M6x20 Spring washer M6 Cable assy Metal fixing Transducer tank, sectional view DS-661 gate valve, sectional view Installation with gate valve DS-661Installation Installation Installation How to open the gate valve Junction Box DS-640 option Mounting considerations Mounting procedureApply silicon rubber to M10 bolts as shown below Pass the cable through the cable gland as shown below How to change orientation of the front cover of DS-605 Remote Controller RD-501/Dimmer Controller RD-502 optionRate-of-Turn Gyro DS-340 option Leveling adjustmentThis page is intentionally left blank Precautions for cable installation WiringTop cover Cable clamps, entrances Connection of Wago connectorTB3 TB1 TB5 TB2 TB4 TB8 DS-610 Distributor Unit DS-620 Transceiver unit DS-600 Display unit DS-600, example of connection DS-640 Junction Box Junction Box DS-640, optionHow to Use the Service Menu Menu SettingsMenu item Meaning Option How to show the System menu How to Set the System MenuHow to set ship’s data Meaning Setting range How to enter offset valuesHow to correct the ship’s speed This page is intentionally left blank Milepost run AP-1Calculation with transit posts Calculation with DS-60 AP-2AP-3 AP-4 Appendix 2 JIS Cable Guide+/05+105+0&4#9+014440%10. #% #6 #6 52#42#465.+5614 5 #%%5514+5 Page Page Page Dec/08 R.Esumi Mar/09 R.Esumi Dec/08 R.Esumi 14/Jul/09 R.Esumi 14/Jul/09 R.Esumi 26/Oct/09 R.Esumi Dec/08 R.Esumi Dec/08 R.Esumi Dec/08 R.Esumi Doppler Sonar