Furuno DS-60 Installation with gate valve DS-661, DS-661 gate valve, sectional view

Page 17

1. INSTALLATION

1.4.3Installation with gate valve DS-661

13 12 11

23 24 25

10 9

8

22 2120

7

 

16

 

15

4

14

17 18 19

 

 

5

 

6

 

2

 

26 27

 

17 18

 

5

3

1

DS-661 gate valve, sectional view

Note: To install the gate valve, service space of 1000 mm height is necessary. For details, see the installation drawing at the back of this manual.

1.When your unit is shipped assembled, remove the five items shown below:

Gate valve (2)

Spacer (3)

Gasket (5), 2 pcs.

Shaft (6)

Gate valve (2)

Shaft (6)

Gasket 1 (5)

Gasket 2 (5)

Spacer (3)

Fore-Aft line

 

1-11

Image 17
Contents Iii Installation Manual00017233810 Safety Instructions System Configurations Standard supply Equipment ListsOptional Supply Flush mount Display Unit DS-600Mounting consideration Desktop or table underside mount Hanger assembly Type OP26-8, Code NoHow to set the cosmetic cap and alarm lid assy Transceiver Unit DS-620 Installation considerationsDistributor Unit DS-610 Transducer Installation locationTransducer tank DS-660, sectional view Installation using the transducer tank DS-660Hex. bolt 15 Seal washer Fixing plate Hex. bolt M6x20 Spring washer M6 Cable assy Metal fixing Transducer tank, sectional view DS-661 gate valve, sectional view Installation with gate valve DS-661Installation Installation Installation How to open the gate valve Junction Box DS-640 option Mounting considerations Mounting procedureApply silicon rubber to M10 bolts as shown below Pass the cable through the cable gland as shown below How to change orientation of the front cover of DS-605 Remote Controller RD-501/Dimmer Controller RD-502 optionRate-of-Turn Gyro DS-340 option Leveling adjustmentThis page is intentionally left blank Precautions for cable installation WiringTop cover Cable clamps, entrances Connection of Wago connectorTB3 TB1 TB5 TB2 TB4 TB8 DS-610 Distributor Unit DS-620 Transceiver unit DS-600 Display unit DS-600, example of connection DS-640 Junction Box Junction Box DS-640, optionHow to Use the Service Menu Menu SettingsMenu item Meaning Option How to set ship’s data How to Set the System MenuHow to show the System menu Meaning Setting range How to enter offset valuesHow to correct the ship’s speed This page is intentionally left blank Calculation with transit posts AP-1Milepost run Calculation with DS-60 AP-2AP-3 AP-4 Appendix 2 JIS Cable Guide+/05+105+0&4#9+014440%10. #% #6 #6 52#42#465.+5614 5 #%%5514+5 Page Page Page Dec/08 R.Esumi Mar/09 R.Esumi Dec/08 R.Esumi 14/Jul/09 R.Esumi 14/Jul/09 R.Esumi 26/Oct/09 R.Esumi Dec/08 R.Esumi Dec/08 R.Esumi Dec/08 R.Esumi Doppler Sonar