Furuno installation manual AP-2, Calculation with DS-60

Page 44

APPENDIX

2. Calculation with DS-60

To measure the distance run between points A and B by DS-60, do the following:

1.Reset the distance run figure of DS-60 to zero by selecting Reset on the Trip DIST menu at the moment the ship passes point A.

2.Run the ship from A to B at full speed, timing with a stopwatch.

3.Read the distance run (nm) and time taken to run (second) exactly at the moment the shipshape point B.

4.Run the ship from B to A at full speed rehearing to step 1 through 3.

Where,

n1 (nm) = distance run from A to B measured by DS-60 n2 (nm) = distance run from B or A measured by DS-60

Therefore, the average run from A to B measured by DS-60

Therefore, the average ship speeds of run 1 and run 2 are calculated as follows.

Slog1 (kn) = n1/t1 X 3600

Slog2 (kn) = n2/t1 X3600

The average ship speed of round trip is Slog (kn) = (Slog1 + Slog2)/2 ...(6)

3.Speedily error From (5) and (6),

Error = (Sw - Slog)/Slog X 100 (%)... (7)

This error can be corrected at SPEED OFFSET on the system menu as follows:

1.Press the [MENU/ESC] key.

2.Select SYSTEM MENU and press the [ENT] key.

3.Select SPEED OFFSET and press the [ENT] key.

4.Enter the value of error.

Repeat the above procedure several times to satisfy the speed accuracy specification.

AP-2

Image 44
Contents Installation Manual Iii00017233810 Safety Instructions System Configurations Equipment Lists Standard supplyOptional Supply Flush mount Display Unit DS-600Mounting consideration Hanger assembly Type OP26-8, Code No Desktop or table underside mountHow to set the cosmetic cap and alarm lid assy Installation considerations Transceiver Unit DS-620Distributor Unit DS-610 Installation location TransducerInstallation using the transducer tank DS-660 Transducer tank DS-660, sectional viewHex. bolt 15 Seal washer Fixing plate Hex. bolt M6x20 Spring washer M6 Cable assy Metal fixing Transducer tank, sectional view Installation with gate valve DS-661 DS-661 gate valve, sectional viewInstallation Installation Installation How to open the gate valve Junction Box DS-640 option Mounting procedure Mounting considerationsApply silicon rubber to M10 bolts as shown below Pass the cable through the cable gland as shown below Remote Controller RD-501/Dimmer Controller RD-502 option How to change orientation of the front cover of DS-605Leveling adjustment Rate-of-Turn Gyro DS-340 optionThis page is intentionally left blank Wiring Precautions for cable installationConnection of Wago connector Top cover Cable clamps, entrancesTB3 TB1 TB5 TB2 TB4 TB8 DS-610 Distributor Unit DS-620 Transceiver unit DS-600 Display unit DS-600, example of connection Junction Box DS-640, option DS-640 Junction BoxMenu Settings How to Use the Service MenuMenu item Meaning Option How to set ship’s data How to Set the System MenuHow to show the System menu How to enter offset values Meaning Setting rangeHow to correct the ship’s speed This page is intentionally left blank Calculation with transit posts AP-1Milepost run AP-2 Calculation with DS-60AP-3 Appendix 2 JIS Cable Guide AP-4+/05+105+0&4#9+014440%10. #% #6 #6 52#42#465.+5614 5 #%%5514+5 Page Page Page Dec/08 R.Esumi Mar/09 R.Esumi Dec/08 R.Esumi 14/Jul/09 R.Esumi 14/Jul/09 R.Esumi 26/Oct/09 R.Esumi Dec/08 R.Esumi Dec/08 R.Esumi Dec/08 R.Esumi Doppler Sonar