Furuno DS-60 installation manual Mounting considerations, Mounting procedure

Page 23

1. INSTALLATION

1.6Installation of Display Unit with DS-605 (Water Proof Box, option)

For installation of the display unit on the wings of the bridge, use the optional water proof box DS- 605. Fix the DS-605 on the bulkhead and set the display unit therein.

Installation materials for DS-605 (Type: CP66-01731, Code No.: 001-082-660-00)

Name

Type

Code No.

Qty

Remarks

 

 

 

 

 

Seal Washer

03-001-3002-0 RoHS

300-130-020-10

4

 

 

 

 

 

 

Gasket (2)

26-003-1605

100-355-310-10

1

For DS-60

 

 

 

 

 

Washer (2)

26-003-1607

100-355-320-10

2

 

 

 

 

 

 

Cable Gland Washer

JIS F8801 25C

000-172-238-10

2

For RD-50

 

 

 

 

 

Cable Grand Inner gasket

JIS F8801 25C

000-171-892-10

1

 

 

 

 

 

 

Silicon Rubber

S-8400W 50G

000-158-483-10

1

 

 

 

 

 

 

Mounting considerations

The DS-605 has waterproofing protection of IP56. When you select a mounting location for the waterproof box, keep in mind the following points.

Keep the unit away from electromagnetic field-generating equipment like motors and genera- tors.

For maintenance and checking purposes, leave enough space at the sides of the unit and leave slack in cables. See the outline drawing at the back of this manual.

A magnetic compass will be affected if the waterproof box is too close to the magnetic com- pass. Observe the compass safe distances (see page i) to prevent interference to a magnetic compass.

Mounting procedure

Note: Mount the DS-605 on the bulkhead so the cable glands and the drain hole are down.

1.Fix the DS-605 on the wings of the bridge.

1)Insert the seal washer to four fixing holes.

2)Fix the DS-605 with four M10 bolts (dockyard supply).

176 ± 0.5 62 (2.44”) (6.93”)

340 (13.39”)

310 ± 0.5 (12.20”)

Fixing hole 4-ø12

Note: Mount the unit so the cable glands are down.

Cable gland

1-17

Image 23
Contents Iii Installation Manual00017233810 Safety Instructions System Configurations Standard supply Equipment ListsOptional Supply Flush mount Display Unit DS-600Mounting consideration Desktop or table underside mount Hanger assembly Type OP26-8, Code NoHow to set the cosmetic cap and alarm lid assy Transceiver Unit DS-620 Installation considerationsDistributor Unit DS-610 Transducer Installation locationTransducer tank DS-660, sectional view Installation using the transducer tank DS-660Hex. bolt 15 Seal washer Fixing plate Hex. bolt M6x20 Spring washer M6 Cable assy Metal fixing Transducer tank, sectional view DS-661 gate valve, sectional view Installation with gate valve DS-661Installation Installation Installation How to open the gate valve Junction Box DS-640 option Mounting considerations Mounting procedureApply silicon rubber to M10 bolts as shown below Pass the cable through the cable gland as shown below How to change orientation of the front cover of DS-605 Remote Controller RD-501/Dimmer Controller RD-502 optionRate-of-Turn Gyro DS-340 option Leveling adjustmentThis page is intentionally left blank Precautions for cable installation WiringTop cover Cable clamps, entrances Connection of Wago connectorTB3 TB1 TB5 TB2 TB4 TB8 DS-610 Distributor Unit DS-620 Transceiver unit DS-600 Display unit DS-600, example of connection DS-640 Junction Box Junction Box DS-640, optionHow to Use the Service Menu Menu SettingsMenu item Meaning Option How to set ship’s data How to Set the System MenuHow to show the System menu Meaning Setting range How to enter offset valuesHow to correct the ship’s speed This page is intentionally left blank Calculation with transit posts AP-1Milepost run Calculation with DS-60 AP-2AP-3 AP-4 Appendix 2 JIS Cable Guide+/05+105+0&4#9+014440%10. #% #6 #6 52#42#465.+5614 5 #%%5514+5 Page Page Page Dec/08 R.Esumi Mar/09 R.Esumi Dec/08 R.Esumi 14/Jul/09 R.Esumi 14/Jul/09 R.Esumi 26/Oct/09 R.Esumi Dec/08 R.Esumi Dec/08 R.Esumi Dec/08 R.Esumi Doppler Sonar