Furuno DS-60 installation manual Installation using the transducer tank DS-660

Page 13

1. INSTALLATION

1.4.2Installation using the transducer tank DS-660

8

7

6

1615

1312 11

 

5

 

 

 

2

 

 

Hull

4

1

10 9

 

 

 

Transducer tank DS-660, sectional view

1.Remove flange (4), fixing plate (5), fixing gland (6), washer (7) and gasket (8) from the tank.

2.Set the tank to the place which was selected at paragraph 1.4.1.

The “FORE-AFT” line on the tank must be parallel with the line between ship’s fore and aft (error: within 3°).

For horizontal direction, the bottom of the tank (2) must be parallel with the draft.

AFT

FORE

Ship’ s bow

DS-660 Tank, top view

3.Weld the tank (2) to the ship’s hull. The doubling and welding methods are left up to the ship- yard.

4.Paint the tank (2), flange (4) and fixing plate (5) the same color as the ship’s body. Paint only gray-colored areas; for other part, seal with a masking tape.

5.Apply liquid gasket (supplied) to the top of the transducer evenly.

6.Mount the fixing plate (5) on the transducer (1).

7.Attach seal washer (16) to hex. bolt M8x12 (15).

8.Use hex. bolt (15)(16) assembled at step 7 to fasten the transducer (1) and fixing plate (5).

1-7

Image 13
Contents Iii Installation Manual00017233810 Safety Instructions System Configurations Standard supply Equipment ListsOptional Supply Mounting consideration Display Unit DS-600Flush mount Desktop or table underside mount Hanger assembly Type OP26-8, Code NoHow to set the cosmetic cap and alarm lid assy Transceiver Unit DS-620 Installation considerationsDistributor Unit DS-610 Transducer Installation locationTransducer tank DS-660, sectional view Installation using the transducer tank DS-660Hex. bolt 15 Seal washer Fixing plate Hex. bolt M6x20 Spring washer M6 Cable assy Metal fixing Transducer tank, sectional view DS-661 gate valve, sectional view Installation with gate valve DS-661Installation Installation Installation How to open the gate valve Junction Box DS-640 option Mounting considerations Mounting procedureApply silicon rubber to M10 bolts as shown below Pass the cable through the cable gland as shown below How to change orientation of the front cover of DS-605 Remote Controller RD-501/Dimmer Controller RD-502 optionRate-of-Turn Gyro DS-340 option Leveling adjustmentThis page is intentionally left blank Precautions for cable installation WiringTop cover Cable clamps, entrances Connection of Wago connectorTB3 TB1 TB5 TB2 TB4 TB8 DS-610 Distributor Unit DS-620 Transceiver unit DS-600 Display unit DS-600, example of connection DS-640 Junction Box Junction Box DS-640, optionHow to Use the Service Menu Menu SettingsMenu item Meaning Option How to show the System menu How to Set the System MenuHow to set ship’s data Meaning Setting range How to enter offset valuesHow to correct the ship’s speed This page is intentionally left blank Milepost run AP-1Calculation with transit posts Calculation with DS-60 AP-2AP-3 AP-4 Appendix 2 JIS Cable Guide+/05+105+0&4#9+014440%10. #% #6 #6 52#42#465.+5614 5 #%%5514+5 Page Page Page Dec/08 R.Esumi Mar/09 R.Esumi Dec/08 R.Esumi 14/Jul/09 R.Esumi 14/Jul/09 R.Esumi 26/Oct/09 R.Esumi Dec/08 R.Esumi Dec/08 R.Esumi Dec/08 R.Esumi Doppler Sonar