Furuno DS-60 installation manual How to enter offset values, Meaning Setting range

Page 40

3. MENU SETTINGS

2.Select an item, and press the [ENT] key to show the setting window. Refer to the table in below to enter the dimensions.

Item

Meaning

Setting range

 

 

 

LOA

Ship’s length

50.0 to 400.0 m

 

 

 

B

Ship’s width

5.0 to 100.0 m

 

 

 

L1

Horizontal distance from the ship’s bow to transducer

0.0 m to the setting value for “LOA”

 

 

 

L2

Horizontal distance from port to transducer

0.0 m to the setting value for “B”

 

 

 

L3

Horizontal distance from sip’s bow to GPS antenna

0.0 m to the setting value for “LOA”

 

 

 

L4

Horizontal distance from port to GPS antenna

0.0 m to setting value for “B”

 

 

 

L5

Horizontal distance from ship’s bow and CCRP (bridge)

0.0 m to setting value for “LOA”

 

 

 

D

Horizontal distance between transducers for DS-60 and

0.0 m to (“LOA”-”L1”)

 

echo sounder.

 

 

 

 

3. Press the [MENU/ESC] key to close the menu.

3.2.3How to enter offset values

1. Press S to select [Offset Data], and [ENT] key to show the Offset Data menu.

2. Select [Trim], and press the [ENT] key.

3.Enter the offset value for inclined angle, and press the [ENT] key (setting range: -12.5 to

+12.5°, +: rise at bow).

4.Press T to select [Heel], and press the [ENT] key.

5.Enter the offset value for the heel, and press the [ENT] key (setting range: -12.5 to +12.5°, +: rise at port).

6.Press T to select [XDCR], and press the [ENT] key.

3-4

Image 40
Contents Installation Manual Iii00017233810 Safety Instructions System Configurations Equipment Lists Standard supplyOptional Supply Mounting consideration Display Unit DS-600Flush mount Hanger assembly Type OP26-8, Code No Desktop or table underside mountHow to set the cosmetic cap and alarm lid assy Installation considerations Transceiver Unit DS-620Distributor Unit DS-610 Installation location TransducerInstallation using the transducer tank DS-660 Transducer tank DS-660, sectional viewHex. bolt 15 Seal washer Fixing plate Hex. bolt M6x20 Spring washer M6 Cable assy Metal fixing Transducer tank, sectional view Installation with gate valve DS-661 DS-661 gate valve, sectional viewInstallation Installation Installation How to open the gate valve Junction Box DS-640 option Mounting procedure Mounting considerationsApply silicon rubber to M10 bolts as shown below Pass the cable through the cable gland as shown below Remote Controller RD-501/Dimmer Controller RD-502 option How to change orientation of the front cover of DS-605Leveling adjustment Rate-of-Turn Gyro DS-340 optionThis page is intentionally left blank Wiring Precautions for cable installationConnection of Wago connector Top cover Cable clamps, entrancesTB3 TB1 TB5 TB2 TB4 TB8 DS-610 Distributor Unit DS-620 Transceiver unit DS-600 Display unit DS-600, example of connection Junction Box DS-640, option DS-640 Junction BoxMenu Settings How to Use the Service MenuMenu item Meaning Option How to show the System menu How to Set the System MenuHow to set ship’s data How to enter offset values Meaning Setting rangeHow to correct the ship’s speed This page is intentionally left blank Milepost run AP-1Calculation with transit posts AP-2 Calculation with DS-60AP-3 Appendix 2 JIS Cable Guide AP-4+/05+105+0&4#9+014440%10. #% #6 #6 52#42#465.+5614 5 #%%5514+5 Page Page Page Dec/08 R.Esumi Mar/09 R.Esumi Dec/08 R.Esumi 14/Jul/09 R.Esumi 14/Jul/09 R.Esumi 26/Oct/09 R.Esumi Dec/08 R.Esumi Dec/08 R.Esumi Dec/08 R.Esumi Doppler Sonar