Furuno DS-60 Desktop or table underside mount, Hanger assembly Type OP26-8, Code No

Page 8

1. INSTALLATION

Note: Dimensions for the cutout are different depending on the mounting location, indoor or out- door. For the outdoor mouting, ask dockyard to construct a waterproof case for the display unit.

2.Make four pilot holes for self-tapping screws (diameter: 5 mm) in the location indicated in the illustration on page 1-1.

3.Insert the sponge to the display unit from the rear side.

4.Set the display unit to the cutout and fasten the display unit with four self-tapping screws (5x20).

5.Set a cosmetic cap to each fixing hole on the front panel. See page 1-3.

Desktop or table underside mount

The display unit can be mounted on a desktop or on the underside of a table using the optional hanger. See the outline drawing for details.

Hanger assembly (Type: OP26-8, Code No.: 000-016-313-00)

Name

Type

Code No.

Qty

 

 

 

 

Self-tapping screw

5x20

000-171-997-10

4

 

 

 

 

Binding head screw

M5x12

000-171-999-10

4

 

 

 

 

Hanger assy.

OP26-8-1

001-081-920-00

1

 

 

 

 

1.Remove the hanger mounting plate from the hanger assembly.

2.Fasten the hanger mounting plate to the display unit from the left side and right side with four binding head screws (M5x12).

Hanger mounting plate (left side)

Screw (M5x12)

3.Make a four pilot holes for self-tapping screws (5x20) in the mounting location.

4.Fix the hanger to the mounting location with four self-tapping screws (5x20).

5.Screw knobs into the display unit loosely.

6.Set the display unit to the hanger.

7.Tighten the knobs to fasten the hanger to the display unit.

1-2

Image 8
Contents Installation Manual Iii00017233810 Safety Instructions System Configurations Equipment Lists Standard supplyOptional Supply Flush mount Display Unit DS-600Mounting consideration Hanger assembly Type OP26-8, Code No Desktop or table underside mountHow to set the cosmetic cap and alarm lid assy Installation considerations Transceiver Unit DS-620Distributor Unit DS-610 Installation location TransducerInstallation using the transducer tank DS-660 Transducer tank DS-660, sectional viewHex. bolt 15 Seal washer Fixing plate Hex. bolt M6x20 Spring washer M6 Cable assy Metal fixing Transducer tank, sectional view Installation with gate valve DS-661 DS-661 gate valve, sectional viewInstallation Installation Installation How to open the gate valve Junction Box DS-640 option Mounting procedure Mounting considerationsApply silicon rubber to M10 bolts as shown below Pass the cable through the cable gland as shown below Remote Controller RD-501/Dimmer Controller RD-502 option How to change orientation of the front cover of DS-605Leveling adjustment Rate-of-Turn Gyro DS-340 optionThis page is intentionally left blank Wiring Precautions for cable installationConnection of Wago connector Top cover Cable clamps, entrancesTB3 TB1 TB5 TB2 TB4 TB8 DS-610 Distributor Unit DS-620 Transceiver unit DS-600 Display unit DS-600, example of connection Junction Box DS-640, option DS-640 Junction BoxMenu Settings How to Use the Service MenuMenu item Meaning Option How to set ship’s data How to Set the System MenuHow to show the System menu How to enter offset values Meaning Setting rangeHow to correct the ship’s speed This page is intentionally left blank Calculation with transit posts AP-1Milepost run AP-2 Calculation with DS-60AP-3 Appendix 2 JIS Cable Guide AP-4+/05+105+0&4#9+014440%10. #% #6 #6 52#42#465.+5614 5 #%%5514+5 Page Page Page Dec/08 R.Esumi Mar/09 R.Esumi Dec/08 R.Esumi 14/Jul/09 R.Esumi 14/Jul/09 R.Esumi 26/Oct/09 R.Esumi Dec/08 R.Esumi Dec/08 R.Esumi Dec/08 R.Esumi Doppler Sonar