Furuno DS-60 installation manual Rate-of-Turn Gyro DS-340 option, Leveling adjustment

Page 27

1. INSTALLATION

1.8Rate-of-Turn Gyro DS-340 (option)

The rate-of-turn gyro must be installed, in a location with minimal vibration, so that the sensor in- side the unit is level to within 1 degree. (There is no designation for orientation of the unit.) Select the location considering that the cable for connection with the distributor is 5 m.

Use the four stud bolts, flat washers, spring washers and eight adjust nuts to fix the unit. See the outline drawing at the back of this manual.

Use the XH connector (supplied with DS-340) to connect cables.

Leveling adjustment

This adjustment must be performed while the ship is in dry-dock where it has no heeling and trim- ming inclinations.

Place a T-type level meter on top of the sensor to measure longitudinal and transverse inclination. To level the sensor, turn the adjust bolts.

T-type level meter

Sensor

Adjust bolt

1-21

Image 27
Contents Iii Installation Manual00017233810 Safety Instructions System Configurations Standard supply Equipment ListsOptional Supply Display Unit DS-600 Mounting considerationFlush mount Desktop or table underside mount Hanger assembly Type OP26-8, Code NoHow to set the cosmetic cap and alarm lid assy Transceiver Unit DS-620 Installation considerationsDistributor Unit DS-610 Transducer Installation locationTransducer tank DS-660, sectional view Installation using the transducer tank DS-660Hex. bolt 15 Seal washer Fixing plate Hex. bolt M6x20 Spring washer M6 Cable assy Metal fixing Transducer tank, sectional view DS-661 gate valve, sectional view Installation with gate valve DS-661Installation Installation Installation How to open the gate valve Junction Box DS-640 option Mounting considerations Mounting procedureApply silicon rubber to M10 bolts as shown below Pass the cable through the cable gland as shown below How to change orientation of the front cover of DS-605 Remote Controller RD-501/Dimmer Controller RD-502 optionRate-of-Turn Gyro DS-340 option Leveling adjustmentThis page is intentionally left blank Precautions for cable installation WiringTop cover Cable clamps, entrances Connection of Wago connectorTB3 TB1 TB5 TB2 TB4 TB8 DS-610 Distributor Unit DS-620 Transceiver unit DS-600 Display unit DS-600, example of connection DS-640 Junction Box Junction Box DS-640, optionHow to Use the Service Menu Menu SettingsMenu item Meaning Option How to Set the System Menu How to show the System menuHow to set ship’s data Meaning Setting range How to enter offset valuesHow to correct the ship’s speed This page is intentionally left blank AP-1 Milepost runCalculation with transit posts Calculation with DS-60 AP-2AP-3 AP-4 Appendix 2 JIS Cable Guide+/05+105+0&4#9+014440%10. #% #6 #6 52#42#465.+5614 5 #%%5514+5 Page Page Page Dec/08 R.Esumi Mar/09 R.Esumi Dec/08 R.Esumi 14/Jul/09 R.Esumi 14/Jul/09 R.Esumi 26/Oct/09 R.Esumi Dec/08 R.Esumi Dec/08 R.Esumi Dec/08 R.Esumi Doppler Sonar