Furuno DS-60 installation manual Safety Instructions

Page 3

SAFETY INSTRUCTIONS

Indicates a potentially hazardous situation which, if not avoided, WARNING could result in death or serious injury.

CAUTION

Indicates a potentially hazardous situation which, if not avoided,

may result in minor or moderate injury.

 

 

 

 

Warning, Caution

Prohibitive Action

Mandatory Action

 

 

 

WARNING

Have a qualified serviceman do the installation.

Only qualified personnel should work inside the equipment.

Turn off the power at the switchboard before installing the equipment.

Fire or electrical shock can result if the power on.

Do not install the unit in a place subject to rain or water splash.

Fire or electrical shock can result.

Use the specified power cable.

Fire can result if an incorrect cable is used.

CAUTION

Attach protective earth securely to the ship’s body.

The protective earth (grounding) is required for the AC power supply to prevent electri- cal shock.

Do not weld the tank with transducer to the ship’s hull.

CAUTION

Confirm that the power supply voltage is compatible with the voltage rating of the equipment.

Connection to the wrong power supply can cause fire or damage to the equipment.

The mounting location for the display, distributor and transceiver unit must satisfy the following conditions:

-Away from rain and water splash -Out of direct sunlight

-Away from air conditioner vents

-Moderate and stable in temperature and humidity

Use Chugoku Toso brand Marine Star 20 anti-fouling paint or the equivalent for the transducer.

Coat thinly and evenly. A thick coat can reduce output power.

Observe the compass safe distances to prevent interference to a magnetic compass.

 

Standard

Steering

DS-600

0.60 m

0.40 m

DS-605

0.95 m

0.60 m

DS-610

3.15 m

2.00 m

DS-620

3.20 m

2.05 m

DS-640

1.15 m

0.70 m

DS-340

1.05 m

0.65 m

i

Image 3
Contents Iii Installation Manual00017233810 Safety Instructions System Configurations Standard supply Equipment ListsOptional Supply Display Unit DS-600 Mounting considerationFlush mount Desktop or table underside mount Hanger assembly Type OP26-8, Code NoHow to set the cosmetic cap and alarm lid assy Transceiver Unit DS-620 Installation considerationsDistributor Unit DS-610 Transducer Installation locationTransducer tank DS-660, sectional view Installation using the transducer tank DS-660Hex. bolt 15 Seal washer Fixing plate Hex. bolt M6x20 Spring washer M6 Cable assy Metal fixing Transducer tank, sectional view DS-661 gate valve, sectional view Installation with gate valve DS-661Installation Installation Installation How to open the gate valve Junction Box DS-640 option Mounting considerations Mounting procedureApply silicon rubber to M10 bolts as shown below Pass the cable through the cable gland as shown below How to change orientation of the front cover of DS-605 Remote Controller RD-501/Dimmer Controller RD-502 optionRate-of-Turn Gyro DS-340 option Leveling adjustmentThis page is intentionally left blank Precautions for cable installation WiringTop cover Cable clamps, entrances Connection of Wago connectorTB3 TB1 TB5 TB2 TB4 TB8 DS-610 Distributor Unit DS-620 Transceiver unit DS-600 Display unit DS-600, example of connection DS-640 Junction Box Junction Box DS-640, optionHow to Use the Service Menu Menu SettingsMenu item Meaning Option How to Set the System Menu How to show the System menuHow to set ship’s data Meaning Setting range How to enter offset valuesHow to correct the ship’s speed This page is intentionally left blank AP-1 Milepost runCalculation with transit posts Calculation with DS-60 AP-2AP-3 AP-4 Appendix 2 JIS Cable Guide+/05+105+0&4#9+014440%10. #% #6 #6 52#42#465.+5614 5 #%%5514+5 Page Page Page Dec/08 R.Esumi Mar/09 R.Esumi Dec/08 R.Esumi 14/Jul/09 R.Esumi 14/Jul/09 R.Esumi 26/Oct/09 R.Esumi Dec/08 R.Esumi Dec/08 R.Esumi Dec/08 R.Esumi Doppler Sonar