Teledyne SERIES 4030, HEATED THC manual Pin Out Table, Pin out of 50 pins D-Sub Connector

Page 25

Installation

3.3.3.7NETWORK I/O

A serial digital input/output for local network protocol. At this printing, this port is not yet functional. It is to be used in future options to the instrument. Pins 13 (+) and 29 (–).

3.3.3.8 Pin Out Table

The following table summarizes all the outputs/inputs available in the 50-pin D-Sub connector on the back panel of the Analyzer.

Table 3-4: Pin out of 50 pins D-Sub Connector

Pin #

Description

1

 

2

 

3

+ Output 4-20 ma, Channel 2, ID

4

- Output 4-20 ma, “, Range ID

5

+ Output 4-20 ma, Channel 1, %

6

- Output 4-20 ma, “, % Output

7

- Output 0-1 v (Channel 1)

8

+ Output 0-1 v (Channel 2)

9

 

10

 

11

 

12

 

13

 

14

 

15

 

16

Span Solenoid Return

17

Span Solenoid Hot

18

Range 3 Contact

19

Range 3 Contact

20

Alarm 3 C Contact

21

Range 1 Contact

22

Range 2 Contact

23

- Output 0-1 v (Channel 2)

24

+ Output 0-1 v (Channel 1)

25

 

26

 

27

 

28

Alarm 1 C Contact

29

 

Teledyne Analytical Instruments

23

Image 25
Contents Series 4030 Heated THC Copyright 2004 Teledyne Analytical Instruments Safety Messages Series Additional Safety Information Series Procedure for Removal of Internal Inaccessible Shock Hazards Series Introduction Main Features of the AnalyzerAnalyzer Description Principle of OperationIntroduction ApplicationsInput Porting Sample SystemGas Flow Control System Detection CellFuel and Blanket Air Systems Flame Ionization Detection CellIntroduction Electrometer-Amplifier Anode Power SupplyFlame Ignition Circuit Flame Guard CircuitMounting the Analyzer Unpacking the AnalyzerUser Connections Electrical Power ConnectionsGas Connections Installation Electrical Connections Equipment Interface Connector Pin Arrangement Pin Function Threshold Alarm Pin Contact Pin Out Table Pin out of 50 pins D-Sub Connector4 RS-232 Port Commands via RS-232 InputSupporting Gases Required RS-232 OptionsSample Bypass Vent Activating the Support Gases Placing the System in Operation1 Air Carrier GasFuel Flame IgnitionVerification of the Flame Guard Circuit Analyzer OperationIgnition and/or Flame Guard Circuit Failure Sample PumpOperation Style Conventions Default ParametersEnter Navigation and Data EntryEscape Line Menu StructureMain Menus Autocal is not available for standard configurations Logout Span ANALOG-OUT Adjust Adjusting the Gain Setting up an AUTO-CALPassword Protection Entering a Password Repeat Password Entry Screen Logging Out Model Screen System Self-Diagnostic TestSpan Alarms Function AL-2 Source SMP Range Function Changing Stream Change Stream is not available for standard configurationsAnalog output Adjustment Standby Advanced User FunctionsTiming Qty Description Recommended Spare Parts ListAnalytical Instruments Drawing List