Teledyne SERIES 4030, HEATED THC manual Series 4030 Heated THC

Page 1
P/N M77216
ECO: #XX-XXXX
DATE 12/13/05

Series 4030

INSTRUCTION, OPERATING AND

MAINTENANCE MANUAL FOR

SERIES 4030 HEATED THC

TELEDYNE ANALYTICAL INSTRUMENTS

 

SPAN

SAMPLE

TEMP. GAUGE

SPAN GAS

BYPASS FLOW

DANGER

Toxic and/or flammable gases or liquids may be present in this monitoring system. Personal protective equipment may be required when servicing this instrument.

Hazardous voltages exist on certain components internally which may persist for a time even after the power is turned off and disconnected.

Only authorized personnel should conduct maintenance and/or servicing. Before conducting any maintenance or servicing, consult with authorized supervisor/manager.

Teledyne Analytical Instruments

Image 1
Contents Series 4030 Heated THC Copyright 2004 Teledyne Analytical Instruments Safety Messages Series Additional Safety Information Series Procedure for Removal of Internal Inaccessible Shock Hazards Series Introduction Main Features of the AnalyzerAnalyzer Description Principle of OperationIntroduction ApplicationsInput Porting Sample SystemGas Flow Control System Detection CellFuel and Blanket Air Systems Flame Ionization Detection CellIntroduction Electrometer-Amplifier Anode Power SupplyFlame Ignition Circuit Flame Guard CircuitMounting the Analyzer Unpacking the AnalyzerUser Connections Electrical Power ConnectionsGas Connections Installation Electrical Connections Equipment Interface Connector Pin Arrangement Pin Function Threshold Alarm Pin Contact Pin Out Table Pin out of 50 pins D-Sub Connector4 RS-232 Port Commands via RS-232 InputSupporting Gases Required RS-232 OptionsSample Bypass Vent Activating the Support Gases Placing the System in Operation1 Air Carrier GasFuel Flame IgnitionVerification of the Flame Guard Circuit Analyzer OperationIgnition and/or Flame Guard Circuit Failure Sample PumpOperation Style Conventions Default ParametersEnter Navigation and Data EntryEscape Line Menu StructureMain Menus Autocal is not available for standard configurations Logout Span ANALOG-OUT Adjust Adjusting the Gain Setting up an AUTO-CALPassword Protection Entering a Password Repeat Password Entry Screen Logging Out Model Screen System Self-Diagnostic TestSpan Alarms Function AL-2 Source SMP Range Function Changing Stream Change Stream is not available for standard configurationsAnalog output Adjustment Standby Advanced User FunctionsTiming Qty Description Recommended Spare Parts ListAnalytical Instruments Drawing List