Teledyne HEATED THC, SERIES 4030 manual Autocal is not available for standard configurations

Page 38

Operation

ENTER it. The analyzer will immediately start that function, unless password restrictions have been assigned. (Password assignment is explained in Section 4.4.10).

4.4.4.2EXPANDED MENUS

An exhaustive list of menu messages is provided as follows.

AUTOCAL

-----------------------

AUTO SPAN NOT AVAILABLE

-----------------------

AUTOCAL is not available for standard configurations of the 4030.

PASSWORD

-----------------------

Enter Password 'T' 'A' 'I'

-----------------------

GAIN ADJUST

-----------------------

GAIN 0

-----------------------

-----------------------

Password Incorrect Change Password

-----------------------

-----------------------

Enter New Password 'T' 'A' 'I'

-----------------------

-----------------------

Reenter New Password 'A' 'A' 'A'

-----------------------

-----------------------

Teledyne Analytical Instruments

36

Image 38
Contents Series 4030 Heated THC Copyright 2004 Teledyne Analytical Instruments Safety Messages Series Additional Safety Information Series Procedure for Removal of Internal Inaccessible Shock Hazards Series Main Features of the Analyzer IntroductionPrinciple of Operation Analyzer DescriptionApplications IntroductionSample System Input PortingFuel and Blanket Air Systems Detection CellGas Flow Control System Flame Ionization Detection CellIntroduction Anode Power Supply Electrometer-AmplifierFlame Guard Circuit Flame Ignition CircuitUnpacking the Analyzer Mounting the AnalyzerGas Connections Electrical Power ConnectionsUser Connections Installation Electrical Connections Equipment Interface Connector Pin Arrangement Pin Function Threshold Alarm Pin Contact Pin out of 50 pins D-Sub Connector Pin Out TableCommands via RS-232 Input 4 RS-232 PortRequired RS-232 Options Supporting GasesSample Bypass Vent 1 Air Placing the System in OperationActivating the Support Gases Carrier GasFlame Ignition FuelIgnition and/or Flame Guard Circuit Failure Analyzer OperationVerification of the Flame Guard Circuit Sample PumpOperation Default Parameters Style ConventionsNavigation and Data Entry EnterEscape Menu Structure LineMain Menus Autocal is not available for standard configurations Logout Span ANALOG-OUT Adjust Setting up an AUTO-CAL Adjusting the GainPassword Protection Entering a Password Repeat Password Entry Screen Logging Out System Self-Diagnostic Test Model ScreenSpan Alarms Function AL-2 Source SMP Range Function Change Stream is not available for standard configurations Changing StreamAnalog output Adjustment Timing Advanced User FunctionsStandby Recommended Spare Parts List Qty DescriptionDrawing List Analytical Instruments