Indications and displays on the transmitters
Operation and battery status indication
The red LED (LOW BAT/ON) provides information on the current operating state of the transmitter:
Red LED lit up: | The transmitter is switched on and the capacity of the |
| batteries/accupack BA 2015 is sufficient. |
Red LED flashing: The batteries are/the accupack BA 2015 is going flat (LOW
BAT)!
In addition, the
3 segments: | capacity approx. 100 % |
2 segments: | capacity approx. 70 % |
1 segment: | capacity approx. 30 % |
Battery icon flashing: | LOW BAT |
“MUTE” display
The “MUTE” display appears on the display panel when the transmitter is muted (see: „Muting the transmitters“ on page 23).
Modulation display
The level display for audio signal (AF) shows the modulation of the transmit- ter.
AF peak indication (SK 100 G2 only)
The yellow LED (AF PEAK) at the front of the SK 100 G2 lights up when the audio input level is excessively high (AF peak) and overmodulates the trans- mitter. At the same time, the
“PILOT” display |
|
The “PILOT” display | lights up when the transmitter display panel if the |
pilot tone transmission is activated (see: „Activating/deactivating the pilot tone transmission or pilot tone evaluation“ on page 35).
Display backlighting (SK 100 G2 only)
After pressing a button, the display remains backlit for approx. 15 seconds.
13