Sennheiser W100 manual Attaching the microphones, Positioning the microphones

Page 19

Attaching the microphones

 

Use the microphone clips

to attach the ME 2 and ME 4 clip-on micro-

phones to clothing (e.g. tie, lapel).

Adjust the ME 3 headmic so that a comfortable and secure fit is ensured.

Positioning the microphones

The ME 3 and ME 4 microphones are directional microphones, i.e. their sound inlet should always be directed towards the sound source (e.g. mouth).

The ME 2 with omni-directional pick-up pattern picks up sound equally from all directions. It is the best choice if movements of the speaker’s head have to be compensated for. However, it should be attached as close as possible to the sound source.

Adjust the sensitivity correctly for all microphones/usages (see: „Adjusting the sensitivity (transmitters only)“ on page 32).

SKP 100 G2 plug-on transmitter

Inserting and replacing the batteries

For powering the SKP 100 G2 plug-on transmitter, you can either use two 1.5 V AA size batteries or the rechargeable Sennheiser BA 2015 accupack.

Slide the battery compartment cover in the direction of the embossed arrow and opern the cover.

Insert the two batteries or the BA 2015 accupack as shown in the diagram on the left. Please observe correct polarity when inserting the batteries/ accupack.

Close the battery compartment. The battery compartment cover locks into place with an audible click.

Note:

For accupack operation of the transmitter, only use the BA 2015 accupack In order to ensure optimum operational reliability. For charging the accupack, only use the L 2015 charger. Both the accupack and the charger are available as accessories.

The accupack is fitted with an integrated sensor which is – via a third contact – monitored by the electronics of the transmitter and the charger. The sensor is necessary for the following control purposes:

y The taking into account of the different voltage characteristics of primary cells (batteries) and accupacks. The battery status indications on the displays, the transmission of transmitter battery status information to the rack-mount receivers and the switch-off thresholds at the end of the operating time are corrected correspondingly. Due to the missing sensor, individual rechargeable battery cells will not be identified as accupacks.

y The monitoring of the accupack temperature during charging in the L 2015 charger.

19

Image 19
Contents 100 Thank you for choosing Sennheiser Safety instructionsContents Channel bank system Evolution wireless series ew 100 G2Delivery includes Areas of application System variantsOverview of operating controls Power buttonEM 100 G2 rack-mount receiver EK 100 G2 bodypack receiver SK 100 G2 bodypack transmitter SKP 100 G2 plug-on transmitter SKM 100 G2 radiomicrophone Indications and displays on the receivers Operation and battery status indication EK 100 G2 onlyTransmitter battery status indication EM 100 G2 only RF signal indication EK 100 G2 onlyDisplay backlighting EK 100 G2 only Modulation display of the receiving transmitterPilot display Diversity display EM 100 G2 onlyAF peak indication SK 100 G2 only Operation and battery status indicationIndications and displays on the transmitters Modulation displayMounting the receiver feet Connecting the antennasConnecting the mains unit Preparing the components for useService interface Connecting the amplifier/mixing consoleRack adapter and antenna mount accessories Bottom sides of the receivers Inserting and replacing the batteries Connecting units to the audio outputMounting the bodypack receiver to a camera Connecting the microphone/line cablePositioning the microphones Attaching the microphonesPlugging the plug-on transmitter onto a microphone Changing the microphone head Switching the bodypack receiver/transmitter on/off Using the componentsSwitching the components on/off Switching the rack-mount receiver on/offMuting the SK 100 G2 and SKP 100 G2 transmitters Activating/deactivating the lock modeSwitching the radiomicrophone on/off Muting the transmittersAttaching the bodypack receiver/transmitter to clothing Attaching the components to clothingButtons Operating menuOverview of menus Working with the operating menu Exit Operating menu of the receiversName Operating menu of the transmitters ExitDisply Switching between channel banks Adjustment tips for the operating menuSwitching between the channels in a channel bank Releasing locked channels Adjusting the sensitivity transmitters onlyMulti-channel operation Starting the scan and storing the scan resultAdjusting the squelch threshold receivers only Adjusting the audio output level receivers onlySpecial feature of the SKP 100 G2 plug-on transmitter Entering a name Selecting the standard displayExiting the operating menu Loading the factory-preset default settingsActivating/deactivating the pilot tone transmission or Pilot tone evaluationError checklist If problems occurRecommendations and tips For multi-channel operation Care and maintenanceHDX noise reduction Additional informationField strength-dependent squelch Wireless transmission systemsSquelch Pilot tone squelchDiversity reception System SpecificationsReceivers Microphone heads Connector assignmentTransmitters MicrophonesPage Accessories Batteries or rechargeable batteries Warranty regulationsManufacturer declarations CE Declaration Conformity