5.3Wall Control Panel

A wall control panel is installed as a wall/surface mount product that allows two methods of cable entry. This allows the same product to be used for both; solid masonry walls, where cables are often run externally down a wall, then enter the unit from above; or alternatively on frame constructions where cables are inside the cavity and need to be hidden.

1.Be sure to plan for easy cable entry into unit before affixing the bracket to the surface:

Be sure that there are no electrical cables that will be obstructed or compromised by the method of fixing the bracket (i.e. screws).

The textured surface should be facing the wall. This surface texture assists the use of adhesives if required.

Be sure that the bracket is level and is straight before attaching to the wall.

Allow enough space above the bracket so that when attaching the wall control panel, it is not obstructed.

2.Set the rear panel DIP switches before the wall control panel is locked into bracket:

Refer to Wall Control Panel DIP switch settings, page 24.

3.Connect the RJ45 connector(s), located on the base of the unit, before the wall control panel is attached to bracket:

Be sure to plan and consider the bend radius of cables. It strongly recommended that the shortest possible RJ45 connector is used when terminating, this is to maximize bend radius of cables in the confined space.

Refer to Wall Control Panel, page 18.

4.Place wall control panel onto bracket. Once the 4 lugs have been placed correctly onto the unit, slide the unit down the bracket until it clicks into place.

If the unit does not sit correctly into the lugs, be sure that you have not used screw heads that are too big to fit in the channels on the rear of the unit.

5.Removing the wall control panel from the bracket (if required):

With the use a flat blade screwdriver press down the bracket locking mechanism, located on the bottom right hand side, and gently slide the unit upwards, this removes the unit from the bracket.

Notice!

The maximum number of wall control panel IDs that can be configured via DIP switch is 16 (8 BGM controllers and 8 mic./line controllers). Refer to Wall Control Panel DIP switch settings, page 24 for more information. The maximum safe cable distance from the DSP matrix mixer to the last wall control panel on is 500m. This may be extended with the use of better cable and less wall control panels on that cable run. If the cables are exposed; use black or white CAT5 cables. This makes for a better visual look once installed.

Bosch Security Systems B.V.

Operation manual

2013-06 V1.0

Image 15
Contents Plena matrix Page Table of contents Troubleshooting MaintenanceTechnical Data Business Equipment For commercial or professional use 1SafetySafety precautions 1FCC and IcesEn Safety Plena matrix About this manual Release date Documentation version Reason Document historyPLM-4P125 and PLM‑4P220 Multi channel DSP Amplifiers 3System overviewPC Configuration and User GUI PLM‑8CS 8 Zone Call StationPLM‑WCP Wall Control Panel Plena matrix System overview en 4Planning DSP Matrix Mixer and Amplifiers 5InstallationCall Station 3Wall Control Panel Refer to Wall Control Panel DIP switch settings,See also PC GUI application software installationPC GUI software PC requirements5iOS GUI software Connections Wall Control PanelDescription Number Description Multi channel DSP AmplifierNumber Description 4DSP Matrix Mixer Do not connect any device, other than a PLM‑4Px2x amplifierPanels DSP Matrix Mixer and Amplifiers, 7Configuration Call Station DIP switch settingsCall station ID numbers DIP switch Wall Control Panel DIP switch settings 3Multi Channel DSP Amplifier settings Proceed as follows 4DSP matrix mixer PC GUIDSP matrix mixer GUI main screen DSP matrix mixer PC GUI control functions UserDSP setup Other DSP matrix mixer configurations in the GUIMulti Channel DSP Amplifier PC GUI Plena matrix Configuration en Amplifier GUI main screen Amplifier Bridging Configuration 8Operation 1StartContinue with one of the following chapters Continue with 2Call StationMaking an announcement Pre-settings and selectionsTop LED 0dB attenuation Select the input source Adjust the audio output volume levelWith DSP / PC GUI functionality Standalone without connection to the PC GUIActivate the active override audio input function Activate the amplifier auto standby3Operate the amplifier with the PC GUI RS485 LED 5DSP Matrix Mixer1Activate the override input function Activate the Alert/EVAC override function3Operating the DSP Matrix Mixer/system with the GUI Problem Possible cause Possible solution DSP matrix mixer or TroubleshootingCall stations / Wall Control Problem Possible cause Possible solutionCall station’s microphone 1Customer service 10.3 Check the connectors and grounding Maintenance10.1 Clean the units 10.2 Clean air ventsTechnical Data 11.1 ElectricalDSP Matrix Mixer Amplifier Multi Channel DSP AmplifierLogic inputs 8CS and WCP RS485Connectors 11.1.4 Wall Control Panel Call Station11.2 Mechanical 11.2.1 DSP Matrix Mixer11.2.3 Call Station 11.2.4 Wall Control Panel 11.3.3 Call Station 11.3 Environmental conditionsStandards 11.3.1 DSP Matrix MixerPage Bosch Security Systems B.V