Bosch Appliances V1.0 Problem Possible cause Possible solution, Call stations / Wall Control

Page 42

42 en TroubleshootingPLENA matrix

Problem

Possible cause

Possible solution

 

 

 

 

Amplifier: Fault light lit for

– This is indicating

The amplifier

approx. one second.

protection on that

 

automatically retries the

 

channel (overload or

 

channel after this time (1

 

short condition).

 

min).

 

 

– Note that the amplifier

 

 

 

will not detect a short-

 

 

 

circuit directly without

 

 

 

signal - for instance, if a

 

 

 

short is on the output,

 

 

 

but no signal is being

 

 

 

driven, the amplifier may

 

 

 

not actually be in fault

 

 

 

mode. As soon as

 

 

 

enough signal is present

 

 

 

to activate the current

 

 

 

protection the fault LED

 

 

 

will light.

 

 

 

Amplifier: Fault LED flashes

– This indicates a thermal

– The channel will be

quickly for around 30

error on the channel.

 

reactivated after it has

seconds.

 

 

cooled down.

 

 

 

 

Amplifier: Fault LEDs flash

– This indicates that the

Send immediately for

slowly.

PSU has failed (or

 

service and/or contact

 

thermally cutout).

 

the Bosch authorized

 

 

 

dealer or installer for

 

 

 

assistance.

 

 

 

Call stations / Wall Control

– RS485 ID cannot be

– Check that the switches

Panel's LED keep rotating.

identified.

 

have been full switched

 

 

 

to the appropriate

 

 

 

positions, and reset

 

 

 

power to the unit.

 

 

– Check that the CAT5

 

 

 

cable is not damaged in

 

 

 

anyway.

 

 

Download and connect

 

 

 

with the latest version of

 

 

 

PC GUI and check the

 

 

 

RS485 status "Device >

 

 

 

RS486 device status".

 

 

 

 

2013-06 V1.0

Operation manual

Bosch Security Systems B.V.

Image 42
Contents Plena matrix Page Table of contents Troubleshooting MaintenanceTechnical Data 1FCC and Ices 1SafetySafety precautions Business Equipment For commercial or professional useEn Safety Plena matrix About this manual Document history Release date Documentation version Reason3System overview PLM-4P125 and PLM‑4P220 Multi channel DSP AmplifiersPC Configuration and User GUI PLM‑8CS 8 Zone Call StationPLM‑WCP Wall Control Panel Plena matrix System overview en 4Planning 5Installation DSP Matrix Mixer and AmplifiersCall Station Refer to Wall Control Panel DIP switch settings, 3Wall Control PanelPC requirements PC GUI application software installationPC GUI software See also5iOS GUI software Connections Wall Control PanelDescription Multi channel DSP Amplifier Number DescriptionNumber Description 4DSP Matrix Mixer Do not connect any device, other than a PLM‑4Px2x amplifierPanels DSP Matrix Mixer and Amplifiers, 7Configuration Call Station DIP switch settingsCall station ID numbers DIP switch Wall Control Panel DIP switch settings 3Multi Channel DSP Amplifier settings 4DSP matrix mixer PC GUI Proceed as followsDSP matrix mixer PC GUI control functions User DSP matrix mixer GUI main screenDSP setup Other DSP matrix mixer configurations in the GUIMulti Channel DSP Amplifier PC GUI Plena matrix Configuration en Amplifier GUI main screen Amplifier Bridging Configuration 8Operation 1StartContinue with one of the following chapters 2Call Station Continue withPre-settings and selections Making an announcementTop LED 0dB attenuation Adjust the audio output volume level Select the input sourceStandalone without connection to the PC GUI With DSP / PC GUI functionalityActivate the active override audio input function Activate the amplifier auto standby3Operate the amplifier with the PC GUI 5DSP Matrix Mixer RS485 LED1Activate the override input function Activate the Alert/EVAC override function3Operating the DSP Matrix Mixer/system with the GUI Troubleshooting Problem Possible cause Possible solution DSP matrix mixer orProblem Possible cause Possible solution Call stations / Wall ControlCall station’s microphone 1Customer service 10.2 Clean air vents Maintenance10.1 Clean the units 10.3 Check the connectors and groundingTechnical Data 11.1 ElectricalDSP Matrix Mixer 8CS and WCP RS485 Multi Channel DSP AmplifierLogic inputs AmplifierConnectors Call Station 11.1.4 Wall Control Panel11.2 Mechanical 11.2.1 DSP Matrix Mixer11.2.3 Call Station 11.2.4 Wall Control Panel 11.3.1 DSP Matrix Mixer 11.3 Environmental conditionsStandards 11.3.3 Call StationPage Bosch Security Systems B.V