Bosch Appliances V1.0 operation manual 3Multi Channel DSP Amplifier settings, Number Description

Page 25

PLENA matrixConfiguration en 25

7.3Multi Channel DSP Amplifier settings

The multi channel DSP amplifier does not require an ID to be connected to the DSP matrix mixer. Amplifier settings that are configured by DIP switches are; input sensitivity and bridging channels together. The DSP features are only able to be configured, after you have connected to the unit using the PC software GUI. Refer to; Multi Channel DSP Amplifier PC GUI, page 28).

Some amplifier settings are configured by DIP switches; such as, the input sensitivity and when bridging channels together.

1/2

3

4

5(4x)

6(4x)

 

POWER

Output 1

 

 

 

 

 

 

0 4Ω 8Ω 70V 100V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output 3

0 4Ω 8Ω 70V 100V

Output 2

0 4Ω 8Ω 70V 100V

Output 4

0 4Ω 8Ω 70V 100V

Input 1

Input 2 Sens

Bridge 1+2

Input 1 Sens

Input 1

Link 1 Link 2

Input 2

Input 3

 

Link 3

Link 4

 

 

Input 2

Input 3

 

Input 4

Input3 Sens Bridge3+4 Input4 Sens

+12V DC

0V DC Sensor +

Sensor -

 

 

 

Link/Act

100Mbps

 

Input 4

 

Active

 

 

Override

 

 

Amp Link Input

 

 

Network

 

 

12(4x)

13

14

7

8 9 10

11

 

 

 

 

 

 

 

 

Number

Item

Description

 

 

 

 

 

 

 

 

 

 

 

 

12

Line input

– 4 x audio input (1-4) level adjustment control:

 

 

 

 

 

control

– The range of attenuation is approximately between 0dB and >50dB.

 

 

 

 

 

13

Input

– 3way DIP switch for input level sensitivity and bridge mode setting:

 

 

sensitivity /

– Switch 1: Input Sensitivity Channel X: 6.15V (UP) / 1.22V (DOWN) input

 

bridge (input 1

sensitivity. Default: DOWN.

 

 

 

 

 

 

and 2 shown)

– Switch 2: Bridge Channels X-Y: Active (UP), Single channel mode (DOWN).

 

 

Default: DOWN.

 

 

 

 

 

 

 

– Switch 3: Input Sensitivity Channel Y: 6.15V (UP) / 1.22V (DOWN) input

 

 

sensitivity. Default: DOWN.

 

 

 

 

 

 

 

 

 

14

Input

– 3way DIP switch for input level sensitivity and bridge mode setting:

 

 

sensitivity /

– Switch 1: Input Sensitivity Channel X: 6.15V (UP) / 1.22V (DOWN) input

 

bridge (input 3

sensitivity. Default: DOWN.

 

 

 

 

 

 

and 4 shown)

– Switch 2: Bridge Channels X-Y: Active (UP), Single channel mode (DOWN).

 

 

Default: DOWN.

 

 

 

 

 

 

 

– Switch 3: Input Sensitivity Channel Y: 6.15V (UP) / 1.22V (DOWN) input

 

 

sensitivity. Default: DOWN.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notice!

Hardware settings cannot be overruled or changed by the GUI configuration software.

See also

DSP matrix mixer PC GUI, page 26

Bosch Security Systems B.V.

Operation manual

2013-06 V1.0

Image 25
Contents Plena matrix Page Table of contents Maintenance TroubleshootingTechnical Data Safety precautions 1Safety1FCC and Ices Business Equipment For commercial or professional useEn Safety Plena matrix About this manual Release date Documentation version Reason Document historyPLM-4P125 and PLM‑4P220 Multi channel DSP Amplifiers 3System overviewPLM‑8CS 8 Zone Call Station PC Configuration and User GUIPLM‑WCP Wall Control Panel Plena matrix System overview en 4Planning DSP Matrix Mixer and Amplifiers 5InstallationCall Station 3Wall Control Panel Refer to Wall Control Panel DIP switch settings,PC GUI software PC GUI application software installationPC requirements See also5iOS GUI software Wall Control Panel ConnectionsDescription Number Description Multi channel DSP AmplifierNumber Description Do not connect any device, other than a PLM‑4Px2x amplifier 4DSP Matrix MixerPanels DSP Matrix Mixer and Amplifiers, Call Station DIP switch settings 7ConfigurationCall station ID numbers DIP switch Wall Control Panel DIP switch settings 3Multi Channel DSP Amplifier settings Proceed as follows 4DSP matrix mixer PC GUIDSP matrix mixer GUI main screen DSP matrix mixer PC GUI control functions UserOther DSP matrix mixer configurations in the GUI DSP setupMulti Channel DSP Amplifier PC GUI Plena matrix Configuration en Amplifier GUI main screen Amplifier Bridging Configuration 1Start 8OperationContinue with one of the following chapters Continue with 2Call StationMaking an announcement Pre-settings and selectionsTop LED 0dB attenuation Select the input source Adjust the audio output volume levelWith DSP / PC GUI functionality Standalone without connection to the PC GUIActivate the amplifier auto standby Activate the active override audio input function3Operate the amplifier with the PC GUI RS485 LED 5DSP Matrix MixerActivate the Alert/EVAC override function 1Activate the override input function3Operating the DSP Matrix Mixer/system with the GUI Problem Possible cause Possible solution DSP matrix mixer or TroubleshootingCall stations / Wall Control Problem Possible cause Possible solutionCall station’s microphone 1Customer service 10.1 Clean the units Maintenance10.2 Clean air vents 10.3 Check the connectors and grounding11.1 Electrical Technical DataDSP Matrix Mixer Logic inputs Multi Channel DSP Amplifier8CS and WCP RS485 AmplifierConnectors 11.1.4 Wall Control Panel Call Station11.2.1 DSP Matrix Mixer 11.2 Mechanical11.2.3 Call Station 11.2.4 Wall Control Panel Standards 11.3 Environmental conditions11.3.1 DSP Matrix Mixer 11.3.3 Call StationPage Bosch Security Systems B.V