Bosch Appliances V1.0 operation manual 4DSP Matrix Mixer, Panels

Page 21

PLENA matrixConnections en 21

6.4DSP Matrix Mixer

Call stations and wall control panels, are connected to the PLM8M8 DSP matrix mixer via CAT5 cable using RJ45 connectors. The multi channel DSP amplifiers are connected to the DSP matrix mixer either via Amp Link or via the output Phoenix connectors. All other connected wiring must be of a professional quality and preferable screened.

1/2

3

 

4

 

 

 

5

 

 

6

 

POWER

Amp Link Out 1-4

Out 1

Out 2

Out 3

Out 4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

Amp Link Out 5-8

 

 

 

Mic/Line 1

Mic/Line 2

Mic/Line 3

Mic/Line 4

Line 5

Line 6

Line 7

 

 

Out 5

Out 6

Out 7

Out 8

 

 

 

 

 

 

7

N.C.

Alert

Evac

Active

 

 

 

 

 

 

 

 

 

0V

Override

910

Control Panels

Link/Act100Mbps

Network

Call Stations

 

 

8

11

 

 

 

 

Number

Item

Description

 

 

 

 

 

1

Power on/off

AC mains supply switch.

 

 

 

 

 

2

Mains inlet

AC mains input socket.

 

 

 

 

 

3

Amp Link

– RJ45 socket for Amp Link connection:

 

 

outputs

– Amp Link 14 output duplicates the outputs of outputs 14.

 

 

 

– Amp Link 58 output duplicates the outputs of outputs 58.

 

 

 

– The maximum cable lenght between DSP matrix mixer and the multi channel

 

 

power amplifier: 5 m / 16.42 ft.

 

 

 

Do not connect any device, other than a PLM4Px2x amplifier!

 

 

 

 

 

4

Phoenix zone

– 3pole Phoenix screw terminal connection per output channel:

 

 

outputs

– Balanced line out.

 

 

 

 

 

5

Mic./Line input

– 4 x XLR balanced microphone/line level audio input (1-4):

 

 

 

– XLR 3pin number connection: 1 = ground, 2 = + signal, 3 = - signal.

 

 

 

 

6

Line inputs

– 3 x 2 RCA summed line input sockets for external music sources.

 

 

 

 

 

7

Active contact

– 4pin pluggable screw socket/connector with ESD protection:

 

 

 

– From left to right; Pin 1: Alert, Pin 2: evac, Pin 3: override, Pin 4: ground.

 

 

– Pin 1, 2 and 3 logic inputs, triggers with ground pin 4.

 

 

 

 

 

8

Override input

4-pin pluggable screw socket/connector with ESD protection:

 

 

 

– Audio line level analog override input (+, - and shield balanced input).

 

 

 

 

9

Network

– RJ45 Ethernet communication socket:

 

 

 

– Communication with the PLENA matrix GUI applications.

 

 

 

 

 

10

Wall control

– RJ45 socket for RS485 data communication, power and audio bus:

 

 

panel

Do not connect any other device, other than wall control panels!

 

 

 

Maximum 16 daisychained wall control panels.

 

 

 

Maximum safe cable distance; 500 m / 1640.42 ft to the final unit.

 

 

 

 

11

Call station

– RJ45 socket for RS485 data communication, power and audio bus:

 

 

 

Do not connect any other device, other than call stations or wall control

 

 

panels!

 

 

 

Maximum 8 daisychained call stations.

 

 

 

Maximum safe cable distance; 500 m / 1640.42 ft to the final unit.

 

 

 

 

 

 

 

 

Bosch Security Systems B.V.

Operation manual

2013-06 V1.0

Image 21
Contents Plena matrix Page Table of contents Troubleshooting MaintenanceTechnical Data Safety precautions 1Safety1FCC and Ices Business Equipment For commercial or professional useEn Safety Plena matrix About this manual Release date Documentation version Reason Document historyPLM-4P125 and PLM‑4P220 Multi channel DSP Amplifiers 3System overviewPC Configuration and User GUI PLM‑8CS 8 Zone Call StationPLM‑WCP Wall Control Panel Plena matrix System overview en 4Planning DSP Matrix Mixer and Amplifiers 5InstallationCall Station 3Wall Control Panel Refer to Wall Control Panel DIP switch settings,PC GUI software PC GUI application software installationPC requirements See also5iOS GUI software Connections Wall Control PanelDescription Number Description Multi channel DSP AmplifierNumber Description 4DSP Matrix Mixer Do not connect any device, other than a PLM‑4Px2x amplifierPanels DSP Matrix Mixer and Amplifiers, 7Configuration Call Station DIP switch settingsCall station ID numbers DIP switch Wall Control Panel DIP switch settings 3Multi Channel DSP Amplifier settings Proceed as follows 4DSP matrix mixer PC GUIDSP matrix mixer GUI main screen DSP matrix mixer PC GUI control functions UserDSP setup Other DSP matrix mixer configurations in the GUIMulti Channel DSP Amplifier PC GUI Plena matrix Configuration en Amplifier GUI main screen Amplifier Bridging Configuration 8Operation 1StartContinue with one of the following chapters Continue with 2Call StationMaking an announcement Pre-settings and selectionsTop LED 0dB attenuation Select the input source Adjust the audio output volume levelWith DSP / PC GUI functionality Standalone without connection to the PC GUIActivate the active override audio input function Activate the amplifier auto standby3Operate the amplifier with the PC GUI RS485 LED 5DSP Matrix Mixer1Activate the override input function Activate the Alert/EVAC override function3Operating the DSP Matrix Mixer/system with the GUI Problem Possible cause Possible solution DSP matrix mixer or TroubleshootingCall stations / Wall Control Problem Possible cause Possible solutionCall station’s microphone 1Customer service 10.1 Clean the units Maintenance10.2 Clean air vents 10.3 Check the connectors and groundingTechnical Data 11.1 ElectricalDSP Matrix Mixer Logic inputs Multi Channel DSP Amplifier8CS and WCP RS485 AmplifierConnectors 11.1.4 Wall Control Panel Call Station11.2 Mechanical 11.2.1 DSP Matrix Mixer11.2.3 Call Station 11.2.4 Wall Control Panel Standards 11.3 Environmental conditions11.3.1 DSP Matrix Mixer 11.3.3 Call StationPage Bosch Security Systems B.V