Micrologic™ 2.0A, 3.0A, 5.0A, and 6.0A Electronic Trip Units

Rev. 01, 07/2012

Appendix A—Register List

 

 

Table 10:

Register List (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

SMS Topic Name

User Description

Number of

Register*

Module*

Units

Scale/Bitmask

Registers*

 

 

 

 

 

 

 

TU_BATT_PCT

 

Trip Unit % Battery

1

8843

PM

%

Unity

TU_SN

 

Trip Unit Serial Number

4

8700

PM

 

ASCII text

 

 

 

 

 

 

 

 

TUCommStatus

 

Trip Unit Internal Comms Status

1

552

BCM

 

Bit 11; ON = not responding, OFF = OK

*For register entries that are not listed, please refer to the Micrologic device type register list. Contact your local sales office.

BCM = Circuit breaker communication module. CCM = Cradle communication module. PM = Trip unit protection module.

3-register date/time format: register 1: month (byte 1) = 1–12, day (byte 2) = 1–31; register 2: year (byte 1) = 0–199 (add to 1900 to determine the actual year), hour

(byte 2) = 0–23; register 3: minutes (byte 1) = 0–59, seconds (byte 2) = 0–59. Note: Bits 14 and 15 of the month/day register must be masked.

**Modulo 10,000 format: 1 to 4 sequential registers. Each register is Modulo 10,000 (range = –9,999 to +9,999). Result is [R4*10,000^3 + R3*10,000^2 + R2*10,000^1] + R1. Range is zero to 9,999,999,999,999,999.

ENGLISH

© 1999–2012 Schneider Electric All Rights Reserved

37-EN

Image 39
Contents Conserver pour usage ultérieur Page Retain for future use Micrologic 2.0A, 3.0A, 5.0A, and 6.0A Electronic Trip UnitsDeath or serious injury Hazard Categories and Special SymbolsPlease Note FCC NoticeTable of Contents List of Registers Rating Plug Removal New Rating Plug InstallationCommunications Trip Unit SettingsGeneral Information IntroductionMicrologic 2.0A Trip Unit Micrologic 3.0A Trip Unit0A Trip Unit Micrologic 5.0A Trip Unit Micrologic 6.0A Trip Unit Zone-Selective Interlocking Trips and clears the fault. Circuit breaker 2 does not tripTrip Unit Switches Micrologic Trip Unit Long-Time Delay ValuesLong-Time Protection Short-Time Protection Micrologic Trip Unit Short-Time Delay ValuesInstantaneous Protection Micrologic Trip Unit Ground-Fault Pickup Values Indicator LightsGround-Fault Protection Overload Indicator LightControl Power Trip Unit TestingMicrologic Trip Unit Configuration Trip Indicator LightsExternal Power Supply Function Specification15-EN Ammeter Measurements Accessing InformationAmmeter Display17-EN Current MenuCurrent Menus Rev , 07/2012 Ammeter18-EN Peak MenuSwitch Settings Menu Switch settings menu displays19-EN Set pickup levels Switch Setting AdjustmentOperation Examples21-EN Set time delaySet Time Delay Rev , 07/2012 OperationSet Time Delays Set time delays22-EN 23-EN Zone-Selective Interlocking ZSIZSI Combinations Units24-EN Wire circuit breakers for zone-selectiveCommunication Module values Interlocking25-EN Set communication module valuesScreen Trip Unit Settings CheckTrip Unit Settings Trip Unit Operation Verification27-EN Equipment Ground-Fault Trip Functions TestingTrip Unit Resetting Trip Unit Status CheckTrip Unit Replacement Required ToolsPreparation Trip Unit Removal Trip Unit ReplacementBattery Installation Rating Plug Removal30-EN Trip Unit Installation31-EN Circuit Breaker Accessory CoverReplacement Close switch cover aTrip Unit Installation Check Trip Unit Setup Circuit Breaker Reconnection32-EN Adjustable Rating Plug Replacement New Rating Plug InstallationRating Plug Removal Circuit Breaker Disconnection Battery ReplacementCircuit Breaker Accessory Cover Removal Battery ReplacementWithstand Module Replacement Rev , 07/2012 Battery Replacement35-EN Module Module Name Equation Address Range Appendix A-Register ListList of Registers Register List37-EN Rev , 07/2012 Appendix A-Register ListSchneider Electric