4 Appliance Preparation

CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during installa- tion. Sheet metal edges are sharp.

A. Securing and Leveling Appliance

Position, level, and secure the appliance.

Place the appliance into position on either a wood or noncombustible continuous flat surface.

Level the appliance from side to side and front to back.

Shim the appliance with noncombustible material, such as sheet metal, as necessary.

Nailing tabs must be moved from shipping position to installation position and secured to framing. Remove screws and reposition nailing tabs as shown in Figure 4.1.

B. Flashing

Flash the fireplace in a manner consistent with regional practices to prevent water penetration around the fireplace. Due to elevated temperatures across the top of the fireplace, metal flashing and high temperature sealant must be used. Adhesive polymeric flashing materials may melt.

For brick, stone, stucco and similar construction, weep screeds should be installed per regional codes.

See Section 3.D. and Figure 3.1 for more information regarding wall and enclosure construction required to prevent moisture penetration into the structure. The fireplace will shed moderate amounts of water but is not waterproof.

NAILING TABS

 

AS SHIPPED

 

 

SECURE TO

 

FRAMING

NAILING TAB

NAILING TAB

SHIPPING POSITION

INSTALLATION POSITION

Figure 4.1 Positioning and Securing Nailing Tab

Outdoor Lifestyles by Hearth & Home Technologies Inc. • Carolina • 4066-300 • Rev. Q • 7/11

10

Image 10
Contents CARODG36I CARODG36IL CARODG42I CARODG42IL Congratulations Listing Label Information/LocationTable of Contents Listing and Code Approvals Getting Started Design and Installation ConsiderationsIf this fireplace is to be installed within a wall, you must Tools and Supplies NeededFraming and Clearances Stand-Alone InstallationBuilt-in Installation Select Appliance Location Clearances and Framing Dimensions CARODG36I, CARODG36IL 1448 mm MinimumNot be placed between Fireplace opening Ceiling/overhang Fireplace Flashing Appliance PreparationSecuring and Leveling Appliance Position, level, and secure the applianceFuel Conversion Control Box Access PanelGas Information Gas PressureValve Access Connect Incoming Gas Line to Manual Shutoff ValveIntelliFire Plus Pilot Ignition System Wiring Electrical InformationNine Hour Safety Shutdown Feature Control Module OperationInstalling the Optional Electric Kit Match holesWire the GFI receptacle as shown below Assemble the junction boxMantel Projections Facing MaterialPilot Shield Install Lava RockPositioning the Logs Notch against grate CAROLINA-42 Place left center log in the indentations on the front left Place Remaining Lava RockLog and the top left log as shown in Figure Install Firescreen Insert RodYour Fireplace Screens Gas Fireplace SafetyOperating Instructions Before Lighting FireplaceLighting the Appliance Final inspection byInitial Break-in Procedure After the Appliance is LitTroubleshooting IntelliFire Plus Ignition SystemTroubleshooting Symptom Possible Cause Corrective ActionMaintaining and Servicing the Appliance Risk of injury or property damage Before servicingMaintenance and Service Tasks Inspect Maintenance TasksAppliance Dimension Diagram Reference MaterialsCARODG42I, CARODG42IL #15 Non Combustible Board Log Set AssemblyService Parts List Part number list on followingStocked At DepotCARODG42I, CARODG42IL #14 Non Combustible BoardTouch up Paint, Fiber Additional service part numbers appear on followingPatch Kit, Fiber Conversion Kit NG#15 Valve Assembly Warranty Outdoor Lifestyles Warranty 2108-975A 10/05/09Limitations of Liability Contact Information