A. Fuel Conversion

Before making gas connections ensure appliance being installed is compatible with the available gas type.

Any natural or propane gas conversions necessary to meet the appliance and locality needs must be made by a quali- fied technician using Hearth & Home Technologies speci- fied and approved parts.

B. Gas Pressure

Proper input pressures are required for optimum appliance performance. Gas line sizing requirements need to be made following NFPA51.

WARNING

Fire Risk

Explosion Risk

High pressure will damage valve.

Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1/2 psig.

Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1/2 psig.

Low pressure may cause explosion.

Pressure requirements for appliance are shown in the table below.

Pressure

Natural Gas

Propane

Minimum Inlet Pressure

5.0 inches w.c.

11.0 inches w.c.

 

 

 

Maximum Inlet Pressure

10.0 inches w.c.

13.0 inches w.c.

Manifold Pressure

3.5 inches w.c.

10.0 inches w.c.

These pressures can be verified through the access panel as shown in Section E. Valve Access.

Note: A listed (and Commonwealth of Massachusetts approved) 1/2 in. (13 mm) T-handle manual shutoff valve and flexible gas connector are connected to the 1/2 in. (13 mm) control valve inlet.

If substituting for these components, please consult local codes for compliance.

Note: Gas line MUST be run from right side of appliance.

The access panel is located below the control box. It will be easier to make gas connection after the control box is in its final position. If necessary, relocate control box prior to making gas connection. See Section 5.E.

Remove the screws holding the access panel.

Set the panel and screws aside for reinstallation.

Control Box

Access Panel

Figure 5.1 Control Box & Access Panel Locations

C. Gas Connection

Note: Have the gas supply line installed in accordance with local building codes, if any. If not, follow ANSI 223.1. Installation should be done by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter.)

If control box is to be relocated, move it at this time to avoid making the gas connection more than once.

The incoming gas line can be installed from the bottom of the fireplace structure, from the side or from the rear (drilling through the cement board may be necessary).

The incoming line should be connected to the 1/2 in. connection on the manual shutoff valve provided with the fireplace.

Outdoor Lifestyles by Hearth & Home Technologies Inc. • Carolina • 4066-300 • Rev. Q • 7/11

11

Image 11
Contents CARODG36I CARODG36IL CARODG42I CARODG42IL Listing Label Information/Location CongratulationsTable of Contents Listing and Code Approvals Tools and Supplies Needed Design and Installation ConsiderationsIf this fireplace is to be installed within a wall, you must Getting StartedSelect Appliance Location Stand-Alone InstallationBuilt-in Installation Framing and Clearances1448 mm Minimum Clearances and Framing Dimensions CARODG36I, CARODG36IL Not be placed between Fireplace opening Ceiling/overhang Fireplace Position, level, and secure the appliance Appliance PreparationSecuring and Leveling Appliance FlashingGas Pressure Control Box Access PanelGas Information Fuel ConversionConnect Incoming Gas Line to Manual Shutoff Valve Valve AccessElectrical Information IntelliFire Plus Pilot Ignition System WiringControl Module Operation Nine Hour Safety Shutdown FeatureMatch holes Installing the Optional Electric KitAssemble the junction box Wire the GFI receptacle as shown belowFacing Material Mantel ProjectionsPositioning the Logs Install Lava RockPilot Shield Notch against grate CAROLINA-42 Log and the top left log as shown in Figure Place Remaining Lava RockPlace left center log in the indentations on the front left Insert Rod Install FirescreenBefore Lighting Fireplace Gas Fireplace SafetyOperating Instructions Your Fireplace ScreensFinal inspection by Lighting the ApplianceAfter the Appliance is Lit Initial Break-in ProcedureIntelliFire Plus Ignition System TroubleshootingSymptom Possible Cause Corrective Action TroubleshootingRisk of injury or property damage Before servicing Maintaining and Servicing the ApplianceInspect Maintenance Tasks Maintenance and Service TasksReference Materials Appliance Dimension DiagramCARODG42I, CARODG42IL Part number list on following Log Set AssemblyService Parts List #15 Non Combustible BoardAt Depot Stocked#14 Non Combustible Board CARODG42I, CARODG42ILConversion Kit NG Additional service part numbers appear on followingPatch Kit, Fiber Touch up Paint, Fiber#15 Valve Assembly Outdoor Lifestyles Warranty 2108-975A 10/05/09 WarrantyLimitations of Liability Contact Information