11 Maintaining and Servicing the Appliance

Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualified service technician should perform an appliance check-up at the beginning of each heating season.

WARNING

Risk of injury or property damage Before servicing:

Turn off gas.

Turn off electricity to appliance.

Disable remote control, if one is present.

Ensure appliance is completely cooled.

After Servicing:

Replace any screen or barrier that was removed.

WARNING

Annual inspection by qualified technician recommended.

Check:

Condition of screen doors.

Obstructions of combustion and ventilation air.

Condition of logs.

Condition of firebox.

Burner ignition and operation.

Clean:

Air passageways, control compartment.

Burner, burner ports.

Risk of:

Fire

Delayed ignition or explosion

Exposure to combustion fumes

Odors

The logs, pilot assembly and front of appliance should be checked periodically for accumulation of soot. Clean pilot and front thoroughly with an emery cloth. Logs may be vacu- umed gently.

Outdoor Lifestyles by Hearth & Home Technologies Inc. • Carolina • 4066-300 • Rev. Q • 7/11

28

Image 28
Contents CARODG36I CARODG36IL CARODG42I CARODG42IL Congratulations Listing Label Information/LocationTable of Contents Listing and Code Approvals Design and Installation Considerations If this fireplace is to be installed within a wall, you mustGetting Started Tools and Supplies NeededStand-Alone Installation Built-in InstallationFraming and Clearances Select Appliance LocationClearances and Framing Dimensions CARODG36I, CARODG36IL 1448 mm MinimumNot be placed between Fireplace opening Ceiling/overhang Fireplace Appliance Preparation Securing and Leveling ApplianceFlashing Position, level, and secure the applianceControl Box Access Panel Gas InformationFuel Conversion Gas PressureValve Access Connect Incoming Gas Line to Manual Shutoff ValveIntelliFire Plus Pilot Ignition System Wiring Electrical InformationNine Hour Safety Shutdown Feature Control Module OperationInstalling the Optional Electric Kit Match holesWire the GFI receptacle as shown below Assemble the junction boxMantel Projections Facing MaterialPilot Shield Install Lava RockPositioning the Logs Notch against grate CAROLINA-42 Place left center log in the indentations on the front left Place Remaining Lava RockLog and the top left log as shown in Figure Install Firescreen Insert RodGas Fireplace Safety Operating InstructionsYour Fireplace Screens Before Lighting FireplaceLighting the Appliance Final inspection byInitial Break-in Procedure After the Appliance is LitTroubleshooting IntelliFire Plus Ignition SystemTroubleshooting Symptom Possible Cause Corrective ActionMaintaining and Servicing the Appliance Risk of injury or property damage Before servicingMaintenance and Service Tasks Inspect Maintenance TasksAppliance Dimension Diagram Reference MaterialsCARODG42I, CARODG42IL Log Set Assembly Service Parts List#15 Non Combustible Board Part number list on followingStocked At DepotCARODG42I, CARODG42IL #14 Non Combustible BoardAdditional service part numbers appear on following Patch Kit, FiberTouch up Paint, Fiber Conversion Kit NG#15 Valve Assembly Warranty Outdoor Lifestyles Warranty 2108-975A 10/05/09Limitations of Liability Contact Information