Hearth and Home Technologies CARODG36I, CARDOG36IL, CARDOG42IL Electrical Information

Page 13

6 Electrical Information

A. IntelliFire Plus™ Pilot Ignition System Wiring

This appliance is equipped with an intermittent pilot ignition (IPI) control which operates on a 6-volt system.

This appliance is supplied with a battery pack which is located in the control box. A wiring diagram is shown in Figure 6.1.

The battery pack requires four batteries (not included).

An optional electric kit is available. This allows the system to be operated with 110/120 VAC instead of batteries. See Section 6.B.

The appliance comes standard with an OFF/ON switch on the control box lid

Optional RC100 wireless wall switch (OFF/ON)

Optional RC200 wireless remote allows flame adjustment (AUX200 is not required since there is no fan used).

Hearth & Home Technologies recommends that IntelliFire PlusTM wireless controls be used for their features and functionality with the IntelliFire PlusTM ignition system.

NOTICE: RC100 & RC200 must be protected from the elements.

The module should be in the REMOTE position when using the switch preinstalled in the control box lid when using the RC100 wireless wall switch. Putting the switch in the OFF position will disable all fireplace controls. See ON/OFF/REMOTE inset, Figure 6.1.

WARNING! Risk of Shock! Replace damaged wire with type 105° C rated wire. Wire must have high temperature insulation.

WARNING! Risk of Shock! Label all wires prior to discon- nection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

Pilot assembly

Valve

GRN

ORG

 

BLK

Module

WHT

ORG

Wiring

 

BLK

harness

BRN

RED

 

 

 

 

 

 

 

RED

RED

 

Jumper

 

 

 

 

 

 

wire

 

 

 

External

 

 

 

Control

 

 

 

Switch

Battery

holder

Battery pack MUST be removed to install the optional electric kit.

Optional Electric Kit

Outlet box/Cover

 

 

 

Power

Outdoor

 

RC200 (optional)

Wiring Assembly

supply

GFI Outlet

 

BLK

 

 

 

 

 

 

RC100 (optional)

 

RED

 

 

 

 

 

 

Figure 6.1 Intermittent Pilot Ignition (IPI) Wiring Diagram

Outdoor Lifestyles by Hearth & Home Technologies Inc. • Carolina • 4066-300 • Rev. Q • 7/11

13

Image 13
Contents CARODG36I CARODG36IL CARODG42I CARODG42IL Listing Label Information/Location CongratulationsTable of Contents Listing and Code Approvals If this fireplace is to be installed within a wall, you must Design and Installation ConsiderationsGetting Started Tools and Supplies NeededBuilt-in Installation Stand-Alone InstallationFraming and Clearances Select Appliance Location1448 mm Minimum Clearances and Framing Dimensions CARODG36I, CARODG36ILNot be placed between Fireplace opening Ceiling/overhang Fireplace Securing and Leveling Appliance Appliance PreparationFlashing Position, level, and secure the applianceGas Information Control Box Access PanelFuel Conversion Gas PressureConnect Incoming Gas Line to Manual Shutoff Valve Valve AccessElectrical Information IntelliFire Plus Pilot Ignition System WiringControl Module Operation Nine Hour Safety Shutdown FeatureMatch holes Installing the Optional Electric KitAssemble the junction box Wire the GFI receptacle as shown belowFacing Material Mantel ProjectionsPilot Shield Install Lava RockPositioning the Logs Notch against grate CAROLINA-42 Place left center log in the indentations on the front left Place Remaining Lava RockLog and the top left log as shown in Figure Insert Rod Install FirescreenOperating Instructions Gas Fireplace SafetyYour Fireplace Screens Before Lighting FireplaceFinal inspection by Lighting the ApplianceAfter the Appliance is Lit Initial Break-in ProcedureIntelliFire Plus Ignition System TroubleshootingSymptom Possible Cause Corrective Action TroubleshootingRisk of injury or property damage Before servicing Maintaining and Servicing the ApplianceInspect Maintenance Tasks Maintenance and Service TasksReference Materials Appliance Dimension DiagramCARODG42I, CARODG42IL Service Parts List Log Set Assembly#15 Non Combustible Board Part number list on followingAt Depot Stocked#14 Non Combustible Board CARODG42I, CARODG42ILPatch Kit, Fiber Additional service part numbers appear on followingTouch up Paint, Fiber Conversion Kit NG#15 Valve Assembly Outdoor Lifestyles Warranty 2108-975A 10/05/09 WarrantyLimitations of Liability Contact Information