Figure 5.2 Connect Incoming Gas Line to Manual Shutoff Valve

Accessibility to the shutoff valve is required after installation, or another accessible shutoff is required.

The flex line and gas shutoff valve can be accessed after installation by removing four screws from the valve mounting bracket at the rear of the control box.

E. Valve Access

The valve and controls are located in the control box (Refer to Figure 5.1). Remove the screws and remove the lid.

Junction Box

Mounting BracketValve (used with optional

electric kit)

Control

Module

Battery Holder

Figure 5.3 Control Box

WARNING! Risk of Fire, Explosion or Asphyxiation! Check all fittings and connections with a non-corrosive commercially available leak-check solution. DO NOT use open flame. Fittings and connections could have loosened during shipping and handling.

WARNING! Rick of Fire or Explosion! Gas build-up dur- ing line purge could ignite.

Purge should be performed by qualified service technician.

Ensure adequate ventilation.

Ensure there are no ignition sources such as sparks or open flames.

D.Electrical Codes

If the optional electrical kit is going to be used, the wiring should be done at this time. See Section 6.A.

NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70- latest edition or the Canadian Electric Code CSA C22.1.

A110/120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes.

National electrical codes require a minimum of three feet of space in front of the access panel for service accessibility.

The control box is designed to be moved out to allow for the thickness of the finish material or moved from the unit and repositioned.

Loosen the two bolts found inside the box in the bottom of the control box.

Slide the box out as necessary.

Tighten the screws.

The control box can be removed from the appliance and repositioned (up to approximately 6 ft. from the appliance).

Make sure the lid will fit over the box without interfering with the finish material.

The control box lid must be accessible and removable.

Caulk around the perimeter of the box to prevent water infiltration.

Note: The control box lid can be painted as desired. Use sandpaper or other abrasive material to scuff the surface prior to painting.

F. High Altitude Installations

NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction.

When installing above 2000 feet elevation:

In the USA: Reduce input rate 4% for each 1000 feet above 2000 feet.

In CANADA: Reduce input rate 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility.

Check with your local gas utility to determine proper orifice size.

Outdoor Lifestyles by Hearth & Home Technologies Inc. • Carolina • 4066-300 • Rev. Q • 7/11

12

Image 12
Contents CARODG36I CARODG36IL CARODG42I CARODG42IL Congratulations Listing Label Information/LocationTable of Contents Listing and Code Approvals Design and Installation Considerations If this fireplace is to be installed within a wall, you mustGetting Started Tools and Supplies NeededStand-Alone Installation Built-in InstallationFraming and Clearances Select Appliance LocationClearances and Framing Dimensions CARODG36I, CARODG36IL 1448 mm MinimumNot be placed between Fireplace opening Ceiling/overhang Fireplace Appliance Preparation Securing and Leveling ApplianceFlashing Position, level, and secure the applianceControl Box Access Panel Gas InformationFuel Conversion Gas PressureValve Access Connect Incoming Gas Line to Manual Shutoff ValveIntelliFire Plus Pilot Ignition System Wiring Electrical InformationNine Hour Safety Shutdown Feature Control Module OperationInstalling the Optional Electric Kit Match holesWire the GFI receptacle as shown below Assemble the junction boxMantel Projections Facing MaterialInstall Lava Rock Pilot ShieldPositioning the Logs Notch against grate CAROLINA-42 Place Remaining Lava Rock Place left center log in the indentations on the front leftLog and the top left log as shown in Figure Install Firescreen Insert RodGas Fireplace Safety Operating InstructionsYour Fireplace Screens Before Lighting FireplaceLighting the Appliance Final inspection byInitial Break-in Procedure After the Appliance is LitTroubleshooting IntelliFire Plus Ignition SystemTroubleshooting Symptom Possible Cause Corrective ActionMaintaining and Servicing the Appliance Risk of injury or property damage Before servicingMaintenance and Service Tasks Inspect Maintenance TasksAppliance Dimension Diagram Reference MaterialsCARODG42I, CARODG42IL Log Set Assembly Service Parts List#15 Non Combustible Board Part number list on followingStocked At DepotCARODG42I, CARODG42IL #14 Non Combustible BoardAdditional service part numbers appear on following Patch Kit, FiberTouch up Paint, Fiber Conversion Kit NG#15 Valve Assembly Warranty Outdoor Lifestyles Warranty 2108-975A 10/05/09Limitations of Liability Contact Information