Problem | Possible Cause | ||
| 1. | Low heat is found in natural | |
|
| gas models. | |
Low heat with the |
|
| |
knob in “HI” | 2. | Ports are blocked. | |
position | |||
|
|
3. LP tank has run out.
Low heat, natural | Gas pressure is significantly | |
affected by gas line and | ||
gas | ||
length of gas line from house | ||
| ||
| gas line. |
| The propane regulator | ||
| assembly incorporates an | ||
| excess flow device designed | ||
Low heat, | to supply the grill with | ||
sufficient gas flow. Rapid | |||
LP gas | |||
changes in pressure can | |||
| |||
| trigger the excess flow device, | ||
| providing a low flame and low | ||
| temperature. | ||
|
|
| |
| 1. | Out of gas. | |
| 2. Excess flow valve tripped. | ||
Sudden drop in |
|
| |
gas flow or low | 3. | Vapor lock at coupling | |
flame |
| nut/LP cylinder | |
|
| connection. |
Corrective Action
1.This model is set for 7 in. natural gas usage. Please check your natural gas supply system to have correct gas pressure.
Regulator is not needed for NG model.
Check the orifice if you installed NG nozzles.
2.Clear ports of any obstructions.
3.Refill the LP tank.
Check your gas line and make corrections by following the chart below.
From House to Grill
Distance | Tubing Size | |
|
| |
Up to 25 ft. | 3/8 in. diameter | |
|
|
|
26 | 1/2 in. diameter | |
|
|
|
|
| 2/3 in. of run 3/4 in. |
51 | 1/3 in. of run 1/2 in. | |
|
|
|
Please follow these instructions:
1.Make sure all burners are “OFF”.
2.Open the tank valve and wait 5 minutes.
3.Light the burner one at a time following the lighting instructions listed on the door liner
1.Check for gas in LP cylinder.
2.Turn off knobs, wait 30 seconds and light grill. If flames are still low, turn off knobs and LP cylinder valve. Disconnect regulator. Reconnect regulator and leak test. Turn on LP cylinder valve, wait 30 seconds and then light grill.
3.Turn off knobs and LP cylinder valve. Disconnect coupling nut from cylinder. Reconnect and retry.
27