Kenmore 148.1615421 manual Natural Gas Hose Connection

Page 24

3.Put the new orifice into the orifice removal tool (B), and then insert the tool into the burner opening and tighten the new orifice into the valve.

Repeat this step for all four burners.

Make sure you are using the correct orifice, which is marked “1.37”. (Fig. 3)

4.Rotate the air shutter opening from the

LP setting to the NG setting. LP: 1/4" open

NG: 1/6" to 1/8" open (Fig. 4)

Natural Gas Hose Connection

B

1.37

Fig. 3

Air shutter opening to adjust

Fig. 4

Remove the LP gas hose and regulator using a wrench, and attach the natural gas hose in it's place. (Fig. 5)

NG Hose

LP gas hose and regulator

Fig. 5

24

Image 24
Contents Kenmore Models/Modelos Item / ArtículoCall Grill Service Center For Help And Parts Safety SymbolsInstallation Safety Precautions Date PurchasedTable of Contents WarrantyUSE and Care LP Tank Removal, Transport and StorageLP Liquefied Petroleum Gas LP Cylinder FillingConnecting Regulator To The LP Tank For your safetyLP Tank Exchange LP Tank Leak TestLeak Testing Valves, Hose and Regulator Turn all grill control knobs to OFFFor Safe Use of Your Grill and to Avoid Serious Injury Turn controls and gas source or tank OFF when not in use General Grill CleaningBurner Flame Check Turning Grill OffCleaning the Burner Assembly Storing Your GrillCorrect burner-to-valve engagement Turn gas off at control knobs and LP cylinderHow To Tell If Meat Is Grilled Thoroughly Food SafetyIndirect Cooking Burner CookingNatural Gas Connection Preparation Operating InstructionsTo disconnect Gas Requirements LP GasHelpful Care and Maintenance Hints Natural GasExcess Flow Control and Low Heat Parts List Key Qty Description ManufacturerParts Diagram Unpacking Rear Panel Beam Right Panel Grill Head Assembly Ground Wire Install the doors Install Wing Tables Wing Table Operation LP Tank Installation Conversion Instructions for Main Burner Conversion Natural Gas Hose Connection Adjust valve control screw Problem Possible Cause Corrective ActionLow heat is found in natural Fecha de compra Símbolos de seguridadPrecauciones de seguridad para la instalación Índice GarantíaUSO Y Cuidado Nunca llene un cilindro a más del 80% de su capacidadIntercambio del tanque LP Prueba de fuga del tanque LPCómo conectar el regulador al tanque de LP Para su seguridadVálvulas para prueba de fugas, manguera y regulador NotaConsejos prácticos sobre seguridad Encendido con fósforos Revisión de la llama del quemadorCómo apagar la parrilla Revisión del encendedorLimpieza del ensamble del quemador Almacenaje de la parrillaEnganche correcto quemador-válvula Cocción indirectaSeguridad alimentaria Cómo saber si la carne está totalmente asadaCocción con 1 quemador Instrucciones para cocción indirectaPreparación de la conexión para gas natural Instrucciones de funcionamientoManguera de extensión de 3,70 m de 3/8 de diámetro interior Para desconectarGas natural Consejos útiles de cuidado y mantenimientoLista DE Piezas Diagrama DE LAS Piezas Desembalaje Tornillo de 3/16-24 x 3/8 Cant.6 Barra frontal Panel derecho Ensamble de la parte principal de la parrilla Conductor de puesta a tierra Instale las puertasInstalación de las mesas laterales Funcionamiento de la mesa lateral Instalación del tanque de GLP Page Conexión de la manguera para gas natural Ajuste el tornillo de control de la válvula Problema Causa posible Acción correctivaProblema Causa posible Acción correctiva HI Alto