3.Put the new orifice into the orifice removal tool (B), and then insert the tool into the burner opening and tighten the new orifice into the valve.
Repeat this step for all four burners.
Make sure you are using the correct orifice, which is marked “1.37”. (Fig. 3)
4.Rotate the air shutter opening from the
LP setting to the NG setting. LP: 1/4" open
NG: 1/6" to 1/8" open (Fig. 4)
Natural Gas Hose Connection
B
1.37
Fig. 3
Air shutter opening to adjust
Fig. 4
Remove the LP gas hose and regulator using a wrench, and attach the natural gas hose in it's place. (Fig. 5)
NG Hose
LP gas hose and regulator
Fig. 5
24