Kenmore 148.1615421 Burner Flame Check, Turn controls and gas source or tank OFF when not in use

Page 8

5.If ignition does not occur in 5 seconds, turn the burner control off, wait 5 minutes for gas to clear away, and repeat the lighting procedure.

6.To light other burners, repeat step 4.

NOTE: If ignitor does not work, follow Match Lighting instructions.

Burner Flame Check

•Remove cooking grates and heat diffusers. Light burners, rotate knobs from HIGH to LOW. You should see a smaller flame in LOW position than seen on HIGH. Perform burner flame check on sideburner, also. Always check flame prior to each use.

Turn controls and gas source or tank OFF when not in use.

If ignition does not occur in 5 seconds, turn the burner control off, wait 5 minutes, and repeat the lighting

procedure. If the burner does not ignite with

the valve open, gas will continue to flow out of the burner and could accidently ignite with risk of injury.

Match-Lighting

Do not lean over grill while lighting.

1.Open lid during lighting.

2.Place match into match holder (hanging from side of cart). Light match, place into the firebox.

3.Push in and turn right knob to HIGH position. Be sure burner lights and stays lit.

4.Light other burners by pushing knob in and turning to HI position.

Turning Grill Off

•Turn all knobs to position. Turn LP cylinder off by turning hand-wheel clockwise to a full stop.

Ignitor Check

•Turn gas off at LP cylinder. Push the control knob in and turn the knob to the left to “HI” position."Click" should be heard and spark seen each time between collector box or burner and electrode. See "Troubleshooting" if no click or spark.

Valve Check

•Important: Make sure gas is off at LP cylinder before checking valves. Knobs lock in OFF position. To check valves, first push in knobs and release, knobs should spring back. If knobs do not spring back, replace valve assembly before using grill. Turn knobs to LOW position then turn back to OFF position. Valves should turn smoothly.

Hose Check

•Before each use, check to see if hoses are cut or worn. Replace damaged hoses before using grill. Use only identical replacement part valve/hose/regulator as specified in the Parts List of this Use and Care Guide.

General Grill Cleaning

•Do not mistake brown or black accumulation of grease and smoke for paint. Interiors of gas grills are not painted at the factory (and should never be painted). Apply a strong solution of detergent and water or use a grill cleaner with scrub brush on insides of grill lid and bottom. Rinse and allow to completely air dry. Do not apply a caustic grill/oven cleaner to painted surfaces.

Plastic parts: Wash with warm soapy water and wipe dry. Do not use citrisol, abrasive cleaners, degreasers or a

concentrated grill cleaner on plastic parts. Damage to and failure of parts can result.

•Porcelain surfaces: Because of glass-like composition, most residue can be wiped away with baking soda/water solution or specially formulated cleaner. Use nonabrasive scouring powder for stubborn stains.

•Painted surfaces: Wash with mild detergent or nonabrasive cleaner and warm soapy water. Wipe dry with a soft nonabrasive cloth.

8

Image 8
Contents Kenmore Models/Modelos Item / ArtículoCall Grill Service Center For Help And Parts Safety SymbolsInstallation Safety Precautions Date PurchasedTable of Contents WarrantyUSE and Care LP Tank Removal, Transport and StorageLP Liquefied Petroleum Gas LP Cylinder FillingConnecting Regulator To The LP Tank For your safetyLP Tank Exchange LP Tank Leak TestLeak Testing Valves, Hose and Regulator Turn all grill control knobs to OFFFor Safe Use of Your Grill and to Avoid Serious Injury Turn controls and gas source or tank OFF when not in use General Grill CleaningBurner Flame Check Turning Grill OffCleaning the Burner Assembly Storing Your GrillCorrect burner-to-valve engagement Turn gas off at control knobs and LP cylinderHow To Tell If Meat Is Grilled Thoroughly Food SafetyIndirect Cooking Burner CookingNatural Gas Connection Preparation Operating InstructionsTo disconnect Gas Requirements LP GasExcess Flow Control and Low Heat Helpful Care and Maintenance HintsNatural Gas Parts List Key Qty Description ManufacturerParts Diagram Unpacking Rear Panel Beam Right Panel Grill Head Assembly Ground Wire Install the doors Install Wing Tables Wing Table Operation LP Tank Installation Conversion Instructions for Main Burner Conversion Natural Gas Hose Connection Adjust valve control screw Problem Possible Cause Corrective ActionLow heat is found in natural Precauciones de seguridad para la instalación Fecha de compraSímbolos de seguridad Índice GarantíaUSO Y Cuidado Nunca llene un cilindro a más del 80% de su capacidadIntercambio del tanque LP Prueba de fuga del tanque LPCómo conectar el regulador al tanque de LP Para su seguridadVálvulas para prueba de fugas, manguera y regulador NotaConsejos prácticos sobre seguridad Encendido con fósforos Revisión de la llama del quemadorCómo apagar la parrilla Revisión del encendedorLimpieza del ensamble del quemador Almacenaje de la parrillaEnganche correcto quemador-válvula Cocción indirectaSeguridad alimentaria Cómo saber si la carne está totalmente asadaCocción con 1 quemador Instrucciones para cocción indirectaPreparación de la conexión para gas natural Instrucciones de funcionamientoManguera de extensión de 3,70 m de 3/8 de diámetro interior Para desconectarGas natural Consejos útiles de cuidado y mantenimientoLista DE Piezas Diagrama DE LAS Piezas Desembalaje Tornillo de 3/16-24 x 3/8 Cant.6 Barra frontal Panel derecho Ensamble de la parte principal de la parrilla Conductor de puesta a tierra Instale las puertasInstalación de las mesas laterales Funcionamiento de la mesa lateral Instalación del tanque de GLP Page Conexión de la manguera para gas natural Ajuste el tornillo de control de la válvula Problema Causa posible Acción correctivaProblema Causa posible Acción correctiva HI Alto